background image

LP & HIGH ALTITUDE LP GAS CONVERSION KIT
FOR INSTALLATIONS IN CANADA

INSTALLATION INSTRUCTIONS

IMPORTANT: Please read all instructions before converting 
the furnace. 

Pay attention to all safety warnings and any other 

special notes highlighted in the manual. Safety markings are 
used frequently throughout this manual to designate a degree 
or level of seriousness and should not be ignored. 

WARNING

 

indicates a potentially hazardous situation that if not avoided, 
could result in personal injury or death.

These conversion instructions are only to be used to convert 
natural gas furnaces to LP/Propane gas in Canada. This kit may 
only be used in furnaces installed in altitudes between zero and 
4,500 feet above sea level. For U.S. installations, the United 
States conversion instructions must be used.

Table 1 is a detailed listing of the components in the LP gas 
conversion kit. Please check the contents of the conversion kit 
with that of the parts listing, and familiarize yourself with each 
component.

For MG2S Series Furnaces & Appliances Using Honeywell Gas Valves

The installer performing this work assumes all responsibility for this conversion. These instructions are primarily intended to assist qualified 

individuals experienced in the proper installation of these components. Some local codes require licensed installation/service personnel for this 

type of equipment. Safety should always be the deciding factor when installing this product and using common sense plays an important role as 

well. Improper installation of the components or failure to follow safety warnings could result in serious injury, death, or property damage. After 

completing the installation, return these instructions to the Homeowner’s Package for owner-user’s future reference.

Table 1. LP Gas & High Altitude Conversion Kit

DESCRIPTION

QTY

Honeywell Conversion Kit 50033841
(to convert VR9205Q1127)

1

#48 Drill Size Burner Orifice Kit (661048)
Included with 60,000 Btu Models (Contains 3)

1

#49 Drill Size Burner Orifice Kit (661049)
Included with 72,000 Btu Models (Contains 4)

1

#51 Drill Size Burner Orifice Kit (661051)
Included with 45,000 Btu Models (Contains 3)

1

#59 Drill Size Burner Orifice Kit (661059)
Included with 45,000 Btu Models (Contains 3)

1

1.1mm Burner Orifice Kit (661078)
Included with 45,000 Btu Models (Contains 3)

1

1.1 mm Burner Orifice Kit (661078)
Included with 60,000 Btu Models (Contains 3) 

1

1.1mm Burner Orifice Kit (661078)
Included with 72,000 Btuh Models (Contains 4)

1

1.2mm Burner Orifice Kit (661079)
Included with 72,000 Btuh Models (Contains 4)

1

1.25 mm Burner Orifice Kit (661082)
Included with 60,000 Btu Models (Contains 3)

1

Conversion Warning Label

1

Conversion Information Label

1

Installation Instructions

1

DO NOT DESTROY THIS MANUAL. KEEP IN A

SAFE PLACE FOR FUTURE REFERENCE.

FIRE OR EXPLOSION HAZARD

• Failure to follow safety warnings exactly could result 

in serious injury or property damage.

•  Installation and service must be performed by a qualified 

installer, service agency or the gas supplier.

•  Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone 

in your building.

• Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire 

department.

WARNING:

RISQUE D’INCENDIE OU D’ EXPLOSION

• Le non-respect des avertissements de sécurité 

pourrait entraîner des blessures graves, la mort ou 
des dommages matériels.

• L’installation et l’entretien doivent être effectués par 

un installateur qualifié, un organisme de service ou le 
fournisseur de gazstaller, service agency or the gas 
supplier.

• Ne pas entreposer ni utiliser de l’essence ni d’autres 

vapeurs ou liquides inflammables dans le voisinage 
de cet appareil, ni de tout autre appareil.

QUE FAIRE S’IL Y A UNE ODEUR DE GAZ

• Ne pas tenter d’allumer aucun appareil.
• Ne toucher à aucun interrupteur électrique; n’utiliser 

aucun téléphone dans le bâtiment.

• Évacuer l’immeuble immédiatement.
• Appeler immédiatement le fournisseur de gaz en 

employant le téléphone d’un voisin. Respecter à la 
lettre les instructions du fournisseur de gaz.

•  Si personne ne répond, appeler le service des incendies.

AVERTISSEMENT