background image

Nortel Ethernet Routing Switch 8300

Installation — AC Power Supply

NN46200-301                              (316797-C Rev 01)

.

Summary of Contents for NN46200-301

Page 1: ...Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 316797 C Rev 01 ...

Page 2: ...l function and or reliability Nortel Networks Inc reserves the right to make changes to the products described in this document without notice Nortel Networks Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein Portions of the code in this software product may be Copyright 1988 Regents of the University of California ...

Page 3: ...al manuals 11 How to get help 12 Power supply installation 13 Navigation 13 Power supplies 13 Removing and installing a power filler panel 17 Installing the AC power supply 18 Removing the AC power supply 20 Electrical specifications for the AC power supply 23 Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networ...

Page 4: ...4 Contents Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks ...

Page 5: ...elease 4 0 Features page 5 Other changes page 5 Features There are no new feature related changes for this document release Other changes This document is reformatted to comply with Nortel Customer Documentation Standards Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks ...

Page 6: ...6 New in this release Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks ...

Page 7: ...ies chassis A qualified service person should have appropriate technical training and experience and be aware of the hazards involved in installing and replacing customer replaceable units This guide provides information about the AC power supply used in the Ethernet Routing Switch 8300 Series chassis and instructions for adding and replacing an AC power supply in the following Ethernet Routing Sw...

Page 8: ...he running configuration If the configuration is saved these settings survive reboots of the switch Interface configuration mode This mode allows you to modify either a logical interface such as a VLAN or a physical interface such as a port slot From either the Global configuration mode or the Interface configuration mode all the configuration parameters both global and interface can be saved to a...

Page 9: ...ing Switch 8300 the default interface is the Ethernet Routing Switch 8300 CLI To switch from the CLI to the NNCLI you must change the NNCLI boot flag to true and save the boot configuration file using the following commands ERS 8310 5 config boot flags nncli true ERS 8310 5 save boot You must reboot the switch for this change to take effect After you reboot the switch access the NNCLI using Telnet...

Page 10: ...ckets Do not type the brackets when entering the command Example If the command syntax is ping ip_address you enter ping 192 32 10 12 bold body text Indicates objects such as window names dialog box names and icons as well as user interface objects such as buttons tabs and menu items bold Courier text Indicates command names options and text that you must enter Example Use the dinfo command Exampl...

Page 11: ...d_route valid_route is one variable and you substitute one value for it plain Courier text Indicates command syntax and system output for example prompts and system messages Example Set Trap Monitor Filters separator Shows menu paths Example Protocols IP identifies the IP command on the Protocols menu vertical line Separates choices for command keywords and arguments Enter only one of the choices ...

Page 12: ...tance If you purchased a Nortel service program contact Nortel Technical Support To obtain contact information online go to the www nortel com contactus web page and click Technical Support Information about the Nortel Technical Solutions Centers is available from the www nortel com callus web page An Express Routing Code ERC is available for many Nortel products and services When you use an ERC y...

Page 13: ... AC power supply for AC input power The following figure shows an Ethernet Routing Switch 8301AC power supply The nominal input voltage range for the 8301AC power supply is 100 120 VAC and 200 240VAC however the output power is limited to 1140 W maximum at 100 120 VAC nominal input voltage conditions To obtain full output power 1770 W you must connect the 8301AC power supply to a 200 240 VAC nomin...

Page 14: ... 120 VAC and 200 240VAC however the output power is limited to 850 W maximum at 100 120 VAC nominal input voltage conditions To obtain full output power 1400W you must connect the 8302AC power supply to a 200 240 VAC nominal input voltage source Figure 2 8302AC power supply Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007...

Page 15: ...odules installed in the chassis PoE requirements whether you want an optional redundant power supply or not Table 3 Recommended 8301AC 8302AC power supplies page 15 lists the number of 8301AC or 8302AC power supplies to install based on the number of installed modules and your power supply redundancy choice To provide the required PoE for powered devices PDs use Table 4 8306 8310 chassis available...

Page 16: ... installed a redundant power supply power available for PoE is always determined on an N 1 redundancy If you have 1 or 2 power supplies in the chassis you will be allocated PoE power equivalent to one power supply If you have 3 power supplies in the chassis you will be allocated PoE power equivalent to 2 power supplies Table 4 8306 8310 chassis available system power Power Supply Power supply rati...

Page 17: ...rewdriver loosen the two captive screws that fasten the power filler panel to the chassis until the screws are free of the threads in the chassis frame 2 Pull the power filler panel out of the Ethernet Routing Switch 8300 Series chassis Save the power filler panel in case you need to operate the Ethernet Routing Switch 8300 Series chassis with a power supply removed End To install a power filler p...

Page 18: ... supplies shut down To correct this condition turn off both power supplies wait at least 30 seconds and then turn on both power supplies again within 2 seconds DANGER Due to high energy hazards of working with components of greater than 240 VA only qualified service personnel are permitted to install and replace Ethernet Routing Switch 8300 components To install an AC power supply Step Action 1 Re...

Page 19: ...p the handle of the new power supply 4 Push the power supply firmly into the bay 5 Tighten the retaining screws until the power supply is seated firmly 6 Connect the power cord to the power supply and to an AC power outlet that is on a circuit with no other equipment connected to it Connect each power supply in the chassis to a separate AC circuit Nortel Ethernet Routing Switch 8300 Installation A...

Page 20: ...place Ethernet Routing Switch 8300 components You can remove a redundant power supply without affecting the operation of the Ethernet Routing Switch 8300 Series switch When you remove a power supply the LED on the power supply turns off and the Ethernet Routing Switch 8300 Series Chassis automatically redistributes the load to the remaining power supplies Nortel Ethernet Routing Switch 8300 Instal...

Page 21: ... you do not have a power filler panel leave the failed power supply installed until a replacement power supply is available To remove an AC power supply Step Action 1 Turn off the power switch on the power supply that you are replacing 2 Disconnect the power cord from the power outlet and from the power supply 3 Loosen the two retaining screws on the power supply Nortel Ethernet Routing Switch 830...

Page 22: ... supply out of the chassis 6 Install a new power supply see Installing the AC power supply page 18 or install a power filler panel see Removing and installing a power filler panel page 17 End Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks ...

Page 23: ... Input voltage range nominal 100 120 VAC 200 240 VAC Input current nominal 16 A 12 A Frequency range nominal 50 60 Hz 50 60 Hz Input VA 1600 VA 2234 VA Input power consumption 1584 W 2212 W Heat dissipation thermal output 1515 BTU hr 1508 BTU hr Hold up time 20 ms 20 ms DC Output Power Ratings Max output power combined 1140W 1050W 90W fans 1770 W 1680W 90W fans Non PoE 3 3 VDC 150 A 3 3 VDC 150 A ...

Page 24: ...sure maximum PoE power or 900 W total for the 50 VDC source at this input voltage condition To obtain the full output power rating of 1770 W you must connect the power supply to a nominal 200 240VAC input voltage source The following table list the power specifications for the Ethernet Routing Switch 8302AC power supply Table 6 Ethernet Routing Switch 8302AC power specifications AC Input Power Rat...

Page 25: ...red to ensure that there is sufficient PoE power or 225 W total at this input voltage condition The maximum steady state output power is limited to a total of 950 W for any combination of output voltages currents excluding the 50 VDC source at high line 200 240VAC nominal input voltage conditions This limitation is required to ensure maximum PoE power or 450 W total for the 50 VDC source at this i...

Page 26: ...6 Appendix Electrical specifications for the AC power supply Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks ...

Page 27: ......

Page 28: ...ed in Canada and the United States of America To provide feedback or report a problem in this document go to www nortel com documentfeedback Nortel the Nortel logo and the Globemark are trademarks of Nortel Networks Adobe and Acrobat Reader are trademarks of Adobe Systems Incorporated Microsoft Windows and Windows NT are trademarks of Microsoft Corporation All other trademarks are the property of ...

Reviews: