background image

Technical instruction
Manual for use and maintenance

GAS COOKER

                              MODELS

FGASE4 • EGASE4 • GASE2 • GASE2A • GASE2B • FGASE6 • EGASE6 • GASE21 •

GASE22 • GASE23 • GASE24 • GASE26

These appliances comply with requirements of E.E.C 90/396

SOTIRIOS D. PRODANAS & CO

PROFESSIONAL ELECTRIC & GAS MACHINES FOR RESTAURANT – PATISSERIES – SNACK BAR

OFFICE – FACTORY

:National Road Kilkis-Thessaloniki (Entrance Galiko) Tel ++30 23410 41819 Fax ++30 23410 41539

P.O Box  400 70,  P.C  : 560 00

www.north.gr

  - e-mail : info@north.gr

Summary of Contents for FGASE4

Page 1: ...ASE23 GASE24 GASE26 These appliances comply with requirements of E E C 90 396 SOTIRIOS D PRODANAS CO PROFESSIONAL ELECTRIC GAS MACHINES FOR RESTAURANT PATISSERIES SNACK BAR OFFICE FACTORY National Road Kilkis Thessaloniki Entrance Galiko Tel 30 23410 41819 Fax 30 23410 41539 P O Box 400 70 P C 560 00 www north gr e mail info north gr ...

Page 2: ...5 0 59 0 79 0 92 27 GASE2B 82 X 40 5 X 43 A INOX CAST IRON 9 0 71 0 95 1 11 32 4 EGAS4 82 X 70 X 43 A INOX CAST IRON 18 1 42 1 90 2 22 64 8 EGAS6 119 X 70 X 43 A INOX CAST IRON 27 2 13 2 86 3 32 97 2 FGASE4 82 X 70 X 95 55x52x25 A INOX CAST IRON INOX 24 5 1 93 2 59 3 02 88 2 FGASE6 119 X 70 X 95 55x52x25 A INOX CAST IRON INOX 33 5 2 64 3 54 4 12 120 6 Unit Big Medium Small Oven Normal Thermal ener...

Page 3: ...level on the surface available If necessary regulate its height accordingly by adjusting the legs of the appliance 1 4 Connection Before connecting the appliance to the network make sure that The gas available it is the one the appliance is regulated for If it is not do not proceed with connection Regulate the appliance for the gas available following instructions under 2 2 Burners are manufacture...

Page 4: ...verall thermal power exceeding 14 Kw must be installed below an air extractor with a switch and pilot for the gas supply system Specifically the supply circuit electric valve at the top of the appliance must be switched off Make sure there are set by installation standard UNI CIG 8723 point 4 3 Removal of combustion products Indicatively the air extractor must guarantee aspiration power equivalent...

Page 5: ...is necessary for another type of gas you should a make sure which type of gas and pressure correspond to the values mentioned in the relevant data table b Choose the right nozzle for the specific type of gas and the pressure available in place keeping in mind data included on Figure 3 of this manual keep in mind that pressure should never exceed 50 mbar and replace nozzle if necessary 2 3 Main bur...

Page 6: ...heck the regulation again 2 4 Operation Control Check that the appliance is level on the supporting surface Make sure there is a good clean air inflow Make sure there are no leaks or loss of gas Set the appliance in operation Check flame stability of both the main and the pilot burner Make sure non combusted gases have an appropriate outlet 2 5 Interventions repairs and replacements for authorized...

Page 7: ...ety which makes sure that the gas flow is interrupted if the flame goes out 2 7 Regulation of minimum burning The by pass valve nozzle has 1 20mm bore and has to be fully screwed for gas G30 In case of regulation for other gases G20 the by pass has to be unscrewed by turning the screw anti clockwise until a clear and regular flame appears In order to regulate the by pass light the burner at the mi...

Page 8: ...ight take some time before the burners light Once the pilot burner is lit keep the handle pressed for a few seconds until thermal safety couple warms well Turn the handle anti clockwise until you bring it to the position of the highest flame and make sure the burner is fully lit The next position is that of the medium flame you can choose this setting once the oven has reached the desirable temper...