SPECIFICATIONS

The tables below refer to the specifications of models ND-6  and  ND-8.

Appliance’

s  Dimensions

MODEL

LENGTH (mm)

WIDTH (mm)

HEIGHT  (mm)

ND-6

     470

      520

       860

ND-8

     470

      520

     1080

Electrical Supply

ND-6

230V  AC / 400V  2N  AC  50Hz

ND-8

230V  AC / 400V  3N  AC  50Hz

IP Grating

P  20

Appliance’

s Safety

Complies to

 60335-1

and

60335-2-42

  requirements.

CE

 marking.

Power
MODEL

POWER IN TOTAL

ND-6

6.400 Watt

ND-8

9.000 Watt

Summary of Contents for ND-6

Page 1: ...ance s Dimensions MODEL LENGTH mm WIDTH mm HEIGHT mm ND 6 470 520 860 ND 8 470 520 1080 Electrical Supply ND 6 230V AC 400V 2N AC 50Hz ND 8 230V AC 400V 3N AC 50Hz IP Grating P 20 Appliance s Safety Complies to 60335 1 and 60335 2 42 requirements CE marking Power MODEL POWER IN TOTAL ND 6 6 400 Watt ND 8 9 000 Watt ...

Page 2: ...nents Wire heating elements ND 6 4 x 1 600 Watt ND 8 5 x 1 800 Watt Spit s motor 100 Watt Fire resistan wiring Terminals fasteners Spit s start up switch with indicating lamp Four position knobs 0 1 2 3 one for every pair of heating elements ND 6 2 pcs ND 8 3 pcs Gland for supply cord Earth terminal Potential equivalent terminal marked Six polar polyamide connection for supply cord ...

Page 3: ...se of incongruence or if in doubt do not connect the apparatus Ask for the equipment to be checked by specialized personnel NORTH Gyros grills equipment are commercial grade appliances and should there for be used by personnel who are specially trained in their use All procedures concerning installation and connection of the appliance must be carried out exclusively by specialized technicians acco...

Page 4: ...SSEMBLY AND CONNECTION PROCEDURES TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS ...

Page 5: ... power supply connect the cables ND 6 Two phases power supply ND 8 hree phases power supply Connect the phases to L1 L2 Connect the earth neutral to 1 or 2 Connect the earth Connect the phases to L1 L2 and L3 Connect the neutral to 1 or 2 Connect the earth Single phase power supply ND 6 ND 8 With the provided bridges and short circuit L1 L2 Connect the phase to L1 or L2 the neutral to 1 or 2 and e...

Page 6: ...ements switches release switch knobs 1 2 3 Unscrew support knobs and screws remove the right side of the appliance and make the replacement For the heating elements release the force feed cables of the heating elements unscrew support nuts take off the heating element and replace it CUT OFF THE POWER SUPPLY BEFORE COVER REMOVAL 2 5TRAINING The personnel who are to install and connect the appliance...

Page 7: ...EQUIPMENT ALL ASSEMBLY AND CONNECTION PROCEDURES TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS ...

Page 8: ...ou have already prepared Secure the spit on the lower base by placing the arm in the appropriate support position Secure the top end of the spit in the appropriate position by locking the safety key Now the Gyros grill appliance is ready to operate All you have to do is set the desired heating element to spit distance about 10 cm and start the rotation motor by pressing switch 3 3 CLEANING AND MAI...