background image

Encoder Installation Manual

EN 61326

NorthStar

 

brand

NexGen RIM Tach 6200 

 MILL-DUTY ENCODER

Key Features

• Stainless Steel and Ductile Cast iron

Construction for a Rugged Heavy Duty
Encoder

• New Sensor Technology provides Extra

Wide Gap for even Higher Reliability

• Extra Heavy Duty Bearings for Long Life
• Convenient LED for Visual indication of

Encoder Functionality

• Foot-Mount or 56-C Face Mount Ideal for

“Flower Pot” or Belt Drive Applications

SPECIFICATIONS

Worldwide Brands:  NorthStar

TM  

•  Acuro

TM  

•  Dynapar

TM

  •  Hengstler

TM

   •  Harowe

TM

European Sales Representitive

Hengstler GmbH (Germany)
Uhlandstrasse 49, 78554 Aldingen
www.hengstler.com

INNOVATION - CUSTOMIZATION - DELIVERY

Customer Service:

Tel.: +1.800.873.8731
Fax: +1.847.662.4150
custserv@dynapar.com

Technical Support

Tel.: +1.800.234.8731
Fax: +1.847.662.4150
northstar.techsupport@dynapar.com

WWW.DYNAPAR.COM

Headquarters: 1675 Delany Road • Gurnee,,IL 60031-1282 • USA

NorthStar™ brand is a trademark of DYNAPAR. All rights reserved.

Document No. 702952-0001,  Rev. 

C

   ©201

2

 DYNAPAR

STANDARD OPERATING CHARACTERISTICS

Code:

 Incremental

Pulses per Revolution:

 60-2048

Phasing Sense: 

A leads B for Counter-Clockwise

rotation (CCW) viewing encoder-mounted end

Quadrature Phasing:

 90

°

 

±

 45

°

Duty Cycle: 

50% 

±

 15%

ELECTRICAL

Input Voltage Requirement: 

5-26 Volts DC

Current Requirement:

 95 mA typical per sensor

module plus line driver load

Output Signals:

 5-26 V Line Driver, 150mA source

or sink

Frequency Response:

 0 - 180kHz  Data & Index

Electrical Immunity: 

2kV ESD, Reverse Polarity,

Short Circuit, Powered Short

Connector: 

10 pin industrial duty latching, sealed

NEMA 4 &12, IP65

MECHANICAL

Shaft Speed: 

7,000 RPM

Mounting Configuration: 

4.5” [115mm]

diameter, 56 C motor face or accessory flange to
meet NEMA MG1-4 standards; foot mount with 4
slotted bolt holes

Housing Material:

 Cast Iron/Stainless Steel

Acceleration Rate: 

3600 rpm/sec max

Shaft :

 0.625” (16mm) diameter with standard

key, single or double ended

Shaft Material Options:

  High Strength Carbon

Steel or Stainless steel

Shaft Axial/Radial Loading:

High Strength Steel:

 50 lbf axial, 50 lbf radial

Stainless Steel:

 35 lbf axial, 35 lbf radial

1
2
3
4
5
6
7
8
9
10

Black
Green
Blue
Violet

Red
Yellow
Gray
Orange
Braid

A
E
D
C

B
H
G
I
J

Signal

Connector Pin

Pigtail Cable

MS 3102E18-IT#

* Index (Z) optional.  See Ordering Information

Common
B
A
Z *
No Connection
Vcc

B

A

Z *
Shield

ENVIRONMENTAL

Operating Temperature Range: 

-40

°

C to +100

°

C

Storage Temperature Range:

 -40

°

C to +120

°

C

Humidity:

 to 100% RH

Shock (Sensor Module):

 1 meter drop test,

30 G’s Min

Vibration: 

18 G’s @ 5-2000 Hz spectrum

ELECTRICAL CONNECTIONS

Summary of Contents for NexGen RIM Tach 6200

Page 1: ...unted end Quadrature Phasing 90 45 Duty Cycle 50 15 ELECTRICAL Input Voltage Requirement 5 26 Volts DC Current Requirement 95 mA typical per sensor module plus line driver load Output Signals 5 26 V Line Driver 150mA source or sink Frequency Response 0 180kHz Data Index Electrical Immunity 2kV ESD Reverse Polarity Short Circuit Powered Short Connector 10 pin industrial duty latching sealed NEMA 4 ...

Page 2: ...lowing general guide lines will help to ensure a trouble free installation Mounting the Encoder Do not shock the encoder Do not subject the encoder to axial or radial shaft stresses Do not tool the encoder or its shaft Do not use makeshift techniques to mount the encoder Do not use a rigid coupling Do not disassemble the encoder Wiring the Encoder Never connect or disconnect the encoder connec tor...

Page 3: ...ut LED STATUS LIGHT A multicolor LED Status light will indicate to the user the overall condition of the encoder The LED is built into the encoder and does not require any additional wiring or power to activate it There are 4 basic status conditions for the light 1 LED off No power to Encoder Low supply voltage 3 0VDC Total Failure of Encoder 2 LED Green Correct Power to Encoder Ready to operate N...

Page 4: ...od Sensor Module 2 0 Preparation The RT 6200 utilizes a modular construction that permits the user to configure the unit as a one or two signal output tachometer Sensor modules are universal and interchangeable If one output requires replacement simply remove four screws and replace with a new sensor module No electrical adjustment or alignment is required After unpacking the unit and verifying re...

Page 5: ...m of the Model 6200 The bolt hole pattern in slotted to permit a measure of adjustment Flexible couplings are generally used to couple the Model 6200 to its driver NorthStar part number RIMFLEX 5858 There are a wide variety of speeds loads environ ment and alignment conditions found in various applications If there is doubt to suitability we recommend you consult the flexible coupling manufacturer...

Page 6: ...e perform the following steps See Figure below 1 Remove sensor module and mating connector from packaging CAUTION Although the device is protected from Electrostatic Discharges up to 2000 Volts standard ESD precautions should be followed 2 Separate mating connector from sensor module by releasing the two latches CAUTION Use caution when handling the sensor module The sensor at the end of the modul...

Page 7: ...on pages 2 3 prior to wiring the encoder 5 1 Quick Release Connector Hood Wiring To install the Quick Release Connector perform the following steps 1 Remove the four screws from the mating connec tor housing that hold the terminal block in place Remove terminal block from housing 2 Insert wiring through liquid tight flexible seal and mating connector housing Leave enough wire exposed to comfortabl...

Page 8: ... Line Driver Output Ordering Information Code 2 PPR Code 1 Model RT6 RT6 Foot Mount or Close Coupled Housing 0060 0064 0075 0120 0128 0150 0240 0256 0300 Code 4 Shaft A Single Shaft Stainless Steel 5 8 B Dual Shaft Stainless Steel 5 8 S Single Shaft Hi strength Steel 5 8 D Dual Shaft Hi Strength Steel 5 8 Code 3 Index L No Index Z With Index Signal Output Code 6 Termination C Latching Industrial C...

Reviews: