background image

 

 

«NOVATEK-ELECTRO» Ltd 

 Intelligent industrial electronics 

                                                                               

 

 

 

 
 
 
 
 

VOLTAGE  RELAY 

                   

  

РН-260t 

 

 

 
 
 
 
 
 

OPERATING MANUAL 

 



 

 
 

Quality control system on the development and production complies with requirements 

ISO 9001:2015 

 

 

 

 

Dear customer

Company NOVATEK-ELECTRO Ltd. thanks you for purchasing our devices. 

You will be able to use properly the device after carefully studying the Operating Manual.  

Keep the Operating Manual throughout the service life of the device. 

 

Review the Operating manual before using the device 

 

 
 
 
 
 
 

UKRAINE, Odessa             

                                                   

 www.novatek-electro.com  

Summary of Contents for PH-260t

Page 1: ...ith requirements ISO 9001 2015 Dear customer Company NOVATEK ELECTRO Ltd thanks you for purchasing our devices You will be able to use properly the device after carefully studying the Operating Manual...

Page 2: ...l Installations Installation adjustment and maintenance of the device must be performed by qualified personnel having studied this Operating Manual In compliance with the requirements of this Operatin...

Page 3: ...arameters to be measured and controlled Name Controlled range Measured range Total power kVA 1 14 0 14 Active power kW 1 14 0 14 Reactive power kVAr 1 14 0 14 Load current A 1 63 0 5 63 Input voltage...

Page 4: ...V 5 Rated mode of operation long Degree of device protection IP 10 Electric shock protection class II Climatic version NF 3 1 Permissible pollution II Overvoltage category II Wire cross section for co...

Page 5: ...installation works may damage the device and connected devices To ensure reliability of electrical connections flexible multi wire conductors with voltage insulation for at least 450 V should be used...

Page 6: ...ons or and choose it by pressing button The device will move to the state Setting of parameters items of the menu are described in Table 4 to change the value of the selected parameter by means of but...

Page 7: ...or if the voltage is higher than 285 V the device will go into the Fault state After the countdown of the re closure time by voltage the device will move to the Normal operation state if the mains vo...

Page 8: ...IF THE DEVICE HAS BEEN OPERATED WITH THE VIOLATION OF THE REQUIREMENTS OF THIS USER MANUAL THE USER WILL LOSE THE RIGHT TO WARRANTY MAINTENANCE 5 4 Warranty service is performed at the place of purcha...