MAINE
VT
NH
MASS
NEW YORK
PENNSYLVANIA
OHIO
IND
ILLINOIS
KENTUCKY
VIRGINIA
NORTH CAROLINA
TENNESSEE
WEST
VIRGINIA
SOUTH
CAROLINA
GEORGIA
ALABAMA
MISS
FLORIDA
LOUISIANA
ARKANSAS
OKLAHOMA
MISSOURI
TEXAS
KANSAS
NEW MEXICO
MEXICO
ARIZONA
CALIFORNIA
NEVADA
UTAH
COLORADO
NEBRASKA
WYOMING
IDAHO
OREGON
SOUTH DAKOTA
IOWA
WISCONSIN
MICHIGAN
MINN
NORTH DAKOTA
MONTANA
WASHINGTON
RHODE ISLAND
CONNECTICUT
NEW JERSEY
MARYLAND
DELAWARE
ASTRONOMIC LATITUDE ZONES
ZONES DE LATITUDE
ZONAS ASTRONOMICAS (LATITUDES)
SUSA
CUSA
NUSA
ALAS
HAWI
PROGRAMMING INSTRUCTIONS
457Z
A DIVISION OF
NSi INDUSTRIES, LLC
PLEASE READ ALL INSTRUCTIONS FIRST
ONE YEAR LIMITED WARRANTY: If this product
fails because of a manufacturing defect within
one year after purchase, we will, at our option,
either repair or replace it at no charge. Our
warranty does not cover damage caused by
accident, abuse or misuse. We assume no
further liability with respect to the sale or use
of this product. THIS WARRANTY IS IN LIEU
OF ALL OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING THE WARRANTY OF
MERCHANTABILITY. We make no warranty with
respect to the fitness of any goods for the users
particular application. This warranty gives you
specific legal rights, and you also may have other
rights which vary from state to state.
It is our intent to provide accurate and current
specification information. However, in the interest
of product improvement, TORK may alter the
specifications or constructional details without
prior notice.
SET
MODE
ENTER
R
1.0 INSTALLATION INSTRUCTION
• Plug the timer into a 120VAC receptacle. If you charge battery
overnight, the unit can be removed and programmed without
AC power.
• Press the
R
(RESET) button by using an insulated tool.
• Press the
ENTER
to start the timer.
2.0 SET TIME AND DATE (CALD)
• Press the
MODE
button two times to display “
CALD”
flashing.
• Press the
ENTER
button to start current time setting mode.
• Using buttons change year, then press
SET
button.
• Continue to using and
SET
button to enter current month,
date, hour, minutes, and seconds.
• Press the
ENTER
button to save the current time setting and return
to clock mode.
3.0 SET SCHEDULE
• Press the
MODE
button to display “PROG” flashing.
• Press the
ENTER
button to display “PROG 1 ON”. This is the first
of 20 ON/OFF pairs. For first ON program, press
SET
. To go to other
programs, press .
3.1 SELECT DAYS
• All days are flashing. Use to choose a different set of days,
then press
SET
.
3.2 SET ON
• Use to choose:
a) “TIME” for a program with user set times
b) “SNUP” for a timer calculated sunrise time that will change daily
throughout the year.
c) “SNST” for a timer calculated sunset time that will change daily
throughout the year.
• Then press
SET
. If “TIME” selected: Use buttons to change
hour, then press
SET
button. Repeat for minutes.
3.3 SET OFF
• “PROG 1 OFF” is flashing on display. Press
SET
.
• All days are flashing. Use to choose a different set of
days, then press
SET
.
• Use to choose:
a) “TIME” for a program with user set times,
b) “SNUP” for a timer calculated sunrise time that will change daily
throughout the year.
c) “SNST” for a timer calculated sunset time that will change daily
throughout the year.
• Then press
SET
. If “TIME” selected: Use buttons to change
hour, then press
SET
button. Repeat for minutes. Press
SET
.
• Repeat steps for a total 20 ON and 20 OFF time settings.
• Press the
ENTER
button to finish programming set and return to
clock mode.
4.0 OPTIONAL SUNSET/SUNRISE TIME ZONES
• Press the
MODE
button three times to display “ZONE” flashing.
• Press the
ENTER
button to start Zone setting mode.
• Use the keys to display the correct zone.
---
NOTE:
NUSA (Default) = North USA, CUSA = Center USA, SUSA = South
USA, ALAS = Alaska&Northern Canada, HAWI = Hawaii&Puerto Rico.
----
• Press the
ENTER
button to save the setting and return to clock
mode.
5.0 OPTIONAL SUNSET/SUNRISE OFFSET
---
NOTE:
This mode displays calculated sunset/sunrise. You can change to
turn ON/OFF earlier or later with this mode.
---
• Press the
MODE
button four times to display “SUN± ” flashing.
• Press the
ENTER
button to start offset mode .
• Screen displays today’s SNUP (sun up) time flashing. Use or
to change default time.
• Press
SET
and screen displays today’s SNST (sunset) time flashing.
Use to change default time.
• Press
ENTER
to complete the setting and back to normal clock
mode.
6.0 OPTIONAL CHANGE DAYLIGHT SAVINGS TIME (DST)
---
NOTE:
Skip this step for default daylight savings dates. Follow instructions
below only if you need to remove or change. MANU (Manual Mode) – no
DST change by timer. NEW mode - change dates to something other than
default dates.
----
• Press the
MODE
button five times to display “DST” flashing.
• Press the
ENTER
button to choose daylight savings times.
• Use the to choose daylight savings options.
a) The display shows “INIT”. For timer to follow current U.S. DST
dates, press
ENTER
.
b) The display shows “MANU”. For no DST adjustment, press
ENTER
.
c) The display shows “NEW”. For modified DST dates, consult
technical support phone line.
7.0 COUNTDOWN TIME SETTING
---
NOTE:
Countdown mode will postpone the manual off for a preset period.
As an example, press button to turn off lights and timer will wait five
minutes before load is shut down. This will give you time to exit the room.
---
• Press the
MODE
button to display “PROG” flashing.
• Press the
ENTER
button to display “PROG 1 ON”.
• Press the once to bring the Countdown time setting.
• Press
SET
for the Countdown (dL) screen.
• Press to choose length of time.
• Press
ENTER
to complete the setting and back to normal clock
mode.
8.0 RANDOM ON/OFF TIME
• Pressed key
SET
& simultaneously to set the Random function.
Display shows “RND”.
• To Cancel Random function simply repeat above procedure. The
“RND” sign will disappear from display.
9.0 OVERRIDE BUTTON FUNCTIONS ( )
• Press one time to turn timer ON or OFF.
10.0 ACTIVATE COUNTDOWN
---
NOTE:
To activate Countdown step 7 must be completed and the timer in
the ON position.
---
• Press
RATINGS
• 120V 15A, 1800W General Purpose
• 120V 15A, 1800W Resistive
• 120V, 960W Tungsten
• 120V 1/3 HP, TV-5
LI-846
FOR TECHNICAL SUPPORT: SOUTIEN TECHNIQUE : PARA COMUNICARSE CON EL SERVICIO TÉCNICO: techsupport@nsiindustries.com 877.230.7874