background image

51-02 Santorini

51-02CP Hammered Copper

51-02H Hacienda

51-02R Richmond

51-14 Santorini

51-14CP Hammered Copper

51-14H Hacienda

51-14R Richmond

CODE AND SUPPLY REQUIREMENTS:   When an appliance is for connection to a fixed piping system, the installation 
must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 
54, International Fuel Gas Code, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and 
Handling Code, B149.2, as applicable.

WARNING:  FOR OUTDOOR USE ONLY

This appliance is designed as an “attended 
appliance”.  Adults must be present when 
the unit is operating.
DO NOT leave this unit burning when 
unattended.  If this product is left burning 
unattended it may cause damage or 
serious injury.

           

WARNING

Improper installation, adjustment, 
alteration, service or maintenance can 
cause injury or property damage.  Read the 
installation, operating and maintenance 
instructions thoroughly before installing or 
servicing this equipment.

              WARNING
Do not store or use gasoline or other flammable vapors and liquids in the 
vicinity of this or any other appliance.

An LP-cylinder not connected for use shall not be stored within 60"
of this unit or any other appliance.

If you smell gas:
1.  Shut off gas to the appliance.
2.  Extinguish any open flame.
3.  If odor continues, keep away from the appliance and immediately call 
your gas supplier or fire department. 

CARBON MONOXIDE HAZARD

    

This appliance can produce carbon 
monoxide which has no odor.

Using it in an enclosed space can kill you.

Never use this appliance in an enclosed 
space such as a camper, tent, car, or home

INSTALLER

  - Owner’s Manual must be left with 

the consumer for future reference.

CONSUMER

 –  Owner’s Manual must be saved for 

future reference.

OWNER'S MANUAL

CASUAL FIRESIDE

A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR

FIRE PIT FOR PROPANE AND *NATURAL GAS

* Needs Conversion Kit

Report #521-O-02-5

http://www.owlee.com/technical-information.aspx

Tested & Certified to

 ANSI Z21.97-2014/CSA 2.41-2014

CGA 2.17-M91 (R2009)

TM

DANGER

DANGER

* Select link below to download French instructions.

Sélectionnez

 

le

 

lien

 

ci

dessous

 

pour

                 

télécharger

 

les

 

instructions

 

françaises.

V2-102115A

Summary of Contents for CASUAL FIRESIDE Santorini 51-02

Page 1: ...ING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored within 60 of this unit or...

Page 2: ...IONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT If not installed and used correctly per these instructions this product can cause serious injury and or property damage CHECK STATE AND LOCAL CODES T...

Page 3: ...inlet gas supply pressure is 10 inches 254 mm water column FOR PROPANE The minimum inlet gas supply pressure for purposes of input adjustment is 8 inches 203 mm water column and the maximum inlet gas...

Page 4: ...it or place any part of the body or combustible materials on the Fire Pit surround Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns...

Page 5: ...inder retention devise provided See illustration above The LP gas supply cylinder to be used must be provided with a listed overfilling prevention device and with a cylinder connection device compatib...

Page 6: ...crucial to safe performance of your Outdoor Fire Pit C Due to high temperatures the Fire Pit must be located out of traffic areas and away from combustibles CAUTION BURN HAZARD LAVA GRANULES WILL REM...

Page 7: ...er the burner Figure 2 Place the larger three logs as desired using the largest log as the support Figure 3 Place the balance of the logs as desired Make sure to leave enough air flow CERAMIC LOG MEDI...

Page 8: ...s for proper air flow Figure 1 Pour the lava granules into the burner support covering the burner completely Figure 2 Place the larger spheres evenly over the edge of the burner CERAMIC ROCK AND SPHER...

Page 9: ...nstalled see figures below for typical control positions FOR YOUR SAFETY READ BEFORE LIGHTING VWARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY D...

Page 10: ...tter so that the air intake holes are open Figure 1 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE THE FIELD CONVERSION FIGURE 1 30 LP NAT C...