background image

DRINKING FOUNTAIN MODELS 

OASIS

®

 ML110RFZ, SUNROC  DFL-2011FR 

 

INSTALLATION NOTES - READ BEFORE INSTALLING FOUNTAINS 

 

1.

 

WARNING:    Installation  must  be  as  follows  to  maintain  frostproof  feature  and  prevent  damage  to  fountain  and/or  water  control 
system: 
a)

 

Water  supply  line  to  fountain  bubbler  must  be  installed  with  a  constant  downslope  from  bubbler  to  control  valve  to  allow 
complete drainage after use. 

b)

 

The control valve box assembly must be installed in an area where the ambient temperature will not fall below 40° F to prevent 
freezing. 

c)

 

Fill inside of fountain completely with a high R-value building insulation. (Note 13) 

d)

 

Before connecting water supply, flush the building water supply line thoroughly to remove any debris inside the line and until the 
water is flowing clear. 

e)

 

Failure  to  comply  with  the  above  may  result  in  damage  or  failure  of  fountain  and/or  water  control  system  and  will  void  all 
warranties. 

2.

 

Note:  The following states require a licensed plumber to install cooler; AR, GA, MA, MI, OK, RI, SC, SD, TX, VT and WI.  
CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well.  State and local plumbing codes may prohibit the 
use of saddle tapping valves for water line connection in some application.  All connections must conform to applicable plumbing 
codes. 

3.

 

Recommended ADA height installation shown.  Adjust vertical dimensions as required to comply with federal, state or local codes. 

4.

 

It  is  the  responsibility  of  the  installer  to  select  the  proper  type  of  mounting  hardware  suitable  for  the  type  of  wall  construction  for 
anchoring the fountain wall bracket and control valve box securely to the wall.  Use 5/16 hardware for these items. 

5.

 

These  fountains  are  designed  for  mounting  to  walls  from  6  to  10”  thick.    For  other  wall  thicknesses  consult  the  Customer  Service 
Department. 

6.

 

Use template for mounting fountain wall bracket first then control valve box.  See instructions for using template. 

7.

 

Level  wall  bracket  and  secure  to  wall.    Slide  splash  panel  over  studs  then  fountain  (remove  bottom  panel)  and  secure  with  6-1/4 
washers and nuts (supplied). 

8.

 

Glue drain assembly tube to control box elbow using primer and glue for PVC.  Push tube to full socket depth of elbow.  Insert drain 
tube  from  control  box  through  drain  hole  and  connect  to drain tube from fountain.  Do not allow debris to enter tube.  Level control 
box and secure to wall.  Tighten drain connector hand tight only.  Seal opening on fountain side. 

9.

 

Install a wall tube (minimum 7/8 ID not supplied) with snug fit in wall to prevent moving, so that the ends extend just inside fountain 
and control box.  Seal opening on fountain side.  Run insulated water supply and air lines through wall tube.  Do not allow debris to 
enter tubes (Note 1a).  Push water supply tube securely into connector-trim excess tubing with sharp knife only.  Remove plastic nut 
from  air  diaphragm,  slide  onto air tube and connect to diaphragm finger tight only-trim excess tubing with sharp knife only.  Do not 
kink, twist or bend sharply either tube. 

10.

 

Select  side  of  control  box  drain  is  to  exit.    Remove  knockout  and  glue  trap in place.  When gluing trap, hold outlet end against box 
and slide other end onto adapter as far as it will go.  Line up remaining drain before gluing trap elbow to trap. 

11.

 

The water supply line (1/2” max.) is installed through the box opening on the opposite side of the drain.  Do not remove the knockout. 
 Connect the water supply to the 3/8 OD flexible tube (connector not supplied) to absorb vibrations and shocks.  Failure to do so may 
damage valve and result in flooding.  Install a shutoff valve outside the box (Note 1d). 

12.

 

Before  filling  fountain  with  insulation,  operate fountain and check for water leaks and proper water drainage from water supply line 
(slide tube insulation apart to expose connector) and drain assembly.  If no leaks join tube insulation ends and wrap with duct tape or 
other suitable tape (not supplied).  (Note 1d) 

13.

 

Fill  with  insulation  (Note  1c)  and  reinstall  bottom  panel  on  fountain.    Remove  knockout  on  drain  side  of  cover  (do  not  remove 
knockout on opposite side) and install on control box with 4-1/4 self-tapping screws (supplied). 

14.

 

Fountains  were  tested  and  adjusted  at  the  factory.    A  minimum  of  30  PSIG  static  pressure  and  1.0  gallon  per  minute  flow  rate  is 
required at the fountain control valve for proper operation.  Maximum pressure not to exceed 80 PSIG. 

15.

 

The  checkstop  houses  a  filter  screen.    To  remove  for  cleaning,  turn  off  water  supply  to  the  fountain.    Turn  the  checkstop  screw 
clockwise until it stops.  Unscrew cover (the filter screen is part of the cover assembly).  To replace, screw cover on housing securely 
and  turn  the  checkstop  screw  counterclockwise  until  it  stops.    Turn  on  water  supply  to  fountain.    Warning:  To  prevent flooding and 
possible bodily injury do not unscrew or remove the checkstop cover without turning off the water supply to the fountain. 

 

 

222 East Campus View Blvd. • Columbus, OH  43235 U.S.A. 

1-800-950-3226 

www.oasiscoolers.com 

 

OASIS is a registered trademark of LVD Acquisiton, LLC dba Oasis International 

© 2012 LVD Acquisition 

A WBENC – Certified Women’s Business Enterprise 

030099-439 

Reviews: