background image

1 of 7 

 

 
 
 

OASIS

®

 VERSACOOLER

®

II MODELS 

PG8ACSL, PG8ACSLTM, PG8ACSLTT, PGV8ACSL, PGF8ACSL, PGF8ACSLTM, PGF8ACSLTT, PGVF8ACSL 

SUNROC MODELS ADA8ACB, ADAV8ACB, ADAACB, ADAF8ACB, ADAVF8AC, ADAFACB 

 

 

INSTRUCTIONS 

 

A.

 

INSPECTION 
Inspect  the  water  cooler,  water  fountain  and  cartons  for  evidence  of  rough  handling  and  concealed  damage.    Damage 
claims should be filed with the carrier. 

B.

 

TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE 
1.

 

NOTE:  The following states require a licensed plumber to install cooler; AG, GA, MA, MI, OK, RI, SC, SD, TX, VT 
and WI. 
CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well.  State and local plumbing codes 
may  prohibit  use  of  saddle  tapping  valves  for  water  line  connection  in  some  applications.    All  connections  must 
conform to applicable plumbing codes. 

2.

 

The PG8ACSL is composed of a water cooler and a water fountain. The water cooler contains the refrigeration system 
and  is  always  mounted  on  the  right  side.  This  unit  can  be  configured  with  the  water  cooler  high  or  low.    Refer  to 
proper roughing in drawing for location of plumbing and electrical service.  Filter units have additional instructions on 
a label inside fountain side access panel.  Read these before installing unit.  This drinking water cooler is designed to 
be operated at a water supply line pressure of up to 100 psi (690 kPa).  A pressure regulator must be installed in 
front  of the unit’s  water inlet if the  water  pressure (including any  possible pressure spikes)  could  exceed 100  psi 
(690 kPa). 

3.

 

FLUSH BUILDING WATER SUPPLY BEFORE INSTALLING UNIT. 

4.

 

Install wall hangers as shown on the desired roughing in drawing.  Wall hangers are shipped fastened to the backs of 
each unit. 

5.

 

To  configure  this  cooler  for  right  side  high  or  right  side  low  installation,  refer  to  details  on  page  3.    Bottom 
screws  of  the  appropriate  side  panel  may  be  temporarily  removed  to  install  patch  plate.    Assemble  drains, 
matching the position of the gaskets to the contour of the cooler tops.  When used with a bottle filler, the unit 
must be configured as a right side high installation. 

6.

 

For refrigerated units, mount the water cooler on the right hanger. 

7.

 

For non-refrigerated units: 

a.

 

TM Models employing touch free sensor and mechanical push button – fountain with the touch free sensor must 

be mounted on left side.  

b.

 

TT Models employing touch free sensor on both units – fountain supplied with power cord attached must be 

mounted on right side.   

8.

 

On TT models, prior to mounting water fountain on left hanger route the loose 2 pin connector of power cord 
from the right-side unit through the open panels and connect into power supply adapter on the shelf inside the 
left side water fountain. Refer to details on page 4. 

9.

 

Mount water fountain on left side hanger while routing “Water In” tube through access hole to stop valve as required. 
Remove cap from “Drain/Remote Cold Water” connection and insert “Water In” tube.  

10.

 

All  provided  waste  drain  parts  for  field  installation  are  packed  in  the  water  fountain.    Assemble  drain  per 
appropriate roughing in drawing.  The short leg of the crossover piece will be on the water cooler side.  When 
unit has an internal waste trap, it should be wrapped with insulating tape to prevent sweating.  Use of 1-3/4” 
knockout for a waste line is not recommended because of potential conflict with ADA* toe space requirements.  
Check with your local building code inspector for approval. 

11.

 

Install a shut off valve in water supply line.  An in-line strainer is furnished in “Water Supply” tube.  Connect “Water 
Supply” tube to shut off valve. This connection should not be a solder joint or flare connection to allow access to the 
strainer service.  To ease removal of the strainer, a sheet metal screw may be lightly threaded into the open end.   

12.

 

Rotate fan blade by hand to see that it is free of obstructions. 

13.

 

Check available power supply against water cooler data plate to ensure correct electrical service.  This drinking water 
cooler is intended to be connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL 