background image

Installation Instructions 

Model Number 1055-AN 

(877) 867-2312

   

   

www.oberonwireless.com 

Rev. 5/20/09

 

Oberon, Inc.  

  1315 South Allen Street  

  State College, PA 16801 

Copyright 2009

 

 

Assembly Components: 
- Ceiling enclosure Model 1055-AN assembly – 1 each 
- #6 - 32 eye bolt – 4 each 
- #10 - 32 screw – 2 each  
- Keys for access door lock – 2 each 

 
If any of these items are missing, contact your Oberon representative. 
 
Find a flat work surface to assemble the 

ceiling enclosure

access point

 and 

antenna(s)

 prior to mounting in ceiling. 

 
Step 1 – Place the 

ceiling enclosure 

assembly

 on the work surface with 

the keyed doorway unlocked. Install 
the 4 eye bolts from the topside of 
the access point enclosure. The 

eyebolts

 will be used to secure the 

enclosure with grid wires. 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Aruba Mounting Plate Installation 

 

Step 2 – Open the locking door and 
place the Aruba Mounting Plate 
(Aruba Part Number AP-120-MNT, 
purchased separately from Aruba) on 
the enclosure’s mounting plate as 
shown with the wider slotted wall 
facing the lock side of the enclosure 
and the narrower slotted wall facing 
the hinged side of the enclosure. 
Secure the Aruba mounting in place 
using two (2) #10-32 screws (Ref. 
Figure 2). 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Aruba Access Point Installation 

 
Step 3 – The Aruba access point is to be installed in the 1055-AN enclosure so that the side with two antennas is nearest the 
hinged side of the enclosure and the side with the single antenna and Ethernet ports are nearest the locking side of the 
enclosure (Ref. Figure 3. 
 
Step 4 – Locate the Aruba AP over the previously installed Aruba mounting plate by first rotating the AP the approximately a 
30° counterclockwise, depress the access point until the bottom surface of the access point is in contact with the Aruba 
mounting plate and rotate approximately 30° clockwise until it snaps into place. (NOTE: Also reference the instructions 
included with the Aruba AP-120-MNT kit). 

            

 

Figure 3 – Proper orientation of the Aruba AP in the 1055-AN enclosure 

 

Figure 1 - Installation of eyebolts 

 

            

 

Figure 2 – Mounting of Aruba AP-120-MNT in Oberon 1055-AN enclosure 