background image

Decon Scrubber

Owner’s Manual

Serial # ____________________

REV0001111209

TM

Summary of Contents for Decon

Page 1: ...Decon Scrubber Owner s Manual Serial ____________________ REV0001111209 TM...

Page 2: ...S Warning 1 Operating the Decon Scrubber 2 System Placement 4 Caring for your Decon Scrubber 5 Cleaning Instructions 6 Optic Replacement Instructions 7 Filter Replacement Instructions 10 Specification...

Page 3: ...nt or repair Use generator only for intended use as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons The use of attachments...

Page 4: ...r of hydroxyl generating optics in operation 4 Hour Meter Quartz non reversible indicator of accumulated hours of use 5 Minihelic Gauge Gauge which senses the static pressure through the 4 inch filter...

Page 5: ...n Once the MAIN POWER switch is on the fan speed can be controlled by rotating the FAN SPEED knob clockwise to increase the speed or counter clockwise to decrease the speed PROCESSOR SWITCH The Decon...

Page 6: ...sition for the system You should position the system as per Figure 1 for efficient decontami nation If you are using two or more systems place them so they blow into the contami nated area to create a...

Page 7: ...exterior OPTIC CLEANING Cleaning of the optics is recommended to maintain peak processing efficiency Fingerprints smudg es dirt dust particles etc will interfere with the hydroxyl production and shoul...

Page 8: ...ews and gently pulling off panel Step 6 Use compressed air to blow out all compartments Step 7 Using a cleaning solution of 10 Isopropyl Alcohol Isopropyl Alcohol strength of 70 or 90 and 90 filtered...

Page 9: ...e front side side opposite handle NOTE Ensure unit is set on a stable non scratch surface CAUTION Unit is heavy Use proper lifting techniques and at least two people to avoid injury Step 4 Remove Phil...

Page 10: ...le pulling from the optic base Step 7 Gently pull optic from three optic supports Note Do not put any pressure on the side of the optic without support Step 8 Gently install new optic by pressing into...

Page 11: ...onnect optic connector Optic connector is keyed and will only connect in one direction If unable to connect optic base with optic connector rotate connector 180 and try again Step 10 Re install bottom...

Page 12: ...the phillips quarter turn fastener counter clockwise on the main filter door Step 4 Swing top of main filter door down Step 5 Remove 4 inch filter Step 6 Install new 4 inch filter NOTE Ensure proper...

Page 13: ...ter door or push and turn the phillips Star quarter turn fastener counter clockwise Step 4 Pull the top of the pre filter door out and lift off Step 5 Remove 2 inch filter Step 6 Install new 2 inch fi...

Page 14: ...the bottom of the door while the top gets pushed in place Step 9 Reinstall Phillips Star screw previously removed or push and turn the phillips Star quarter turn fastener clockwise ENGLISH FILTER REPL...

Page 15: ...artz Hour Meter WARRANTY HGI Industries Inc warrants that this Decon Scrubber excluding spare parts and consumables shall be free from defects in workmanship or materials for a period of one 1 year fr...

Page 16: ...ion and maintenance of your Odorox product please contact your local Odorox distributor Odorox Hydroxyl Generators are proudly manufactured in the USA Copyright 2011 HGI Industries Incorporated Odorox...

Reviews: