background image

Type UCCG, UCDG

U S E R   M A N U A L

Product program
This user manual covers following thermostats with built-in GFCI
UCCG-9991

Incl. floor sensor 3m

UCCG-9999

With built-in room sensor

UCDG-9999

With 2 sensors; built-in room sensor and incl. floor sensor 3m

Introduction
The thermostat is an electronic on/off thermostat for control of temperature by means of an NTC sensor either placed externally or internally in the thermostat. The
thermostat has integrated a Ground Fault Circuit Interrupter (GFCI, Class A). The thermostat and the GFCI is a dual model suitable for 120/240 V 50/60 Hz supply.

The thermostat is capable of switching on your heating system at pre determined times on different days of the week. It is possible to set 4 periods called events
each day with different temperatures. From factory a default schedule is programmed suitable for most installations. Unless you change these settings the
thermostat will operate to this default program. Working with lower temperatures during times that the room is unoccupied will lower your energy costs without
reducing the comfort. The thermostat has an adaptive function that automatically changes the start time of a heating period so that the desired temperature is
reached at the time that you set. After 5 days the adaptive function has learned when the heating must be switched on.

The thermostat type UCCG-9991 has an external temperature sensor that is normally placed in the floor construction. In this configuration the thermostat
controls the temperature of the floor and not the temperature within the room.
The thermostat type UCCG-9999 has a built-in temperature sensor. In this configuration the thermostat controls the temperature of the room.
The thermostat type UCDG-9999 has a built-in temperature sensor and an externally temperature sensor. In this configuration the thermostat
controls the temperature within the room and use the externally temperature sensor as limit sensor avoiding too high or too low temperatures in the floor
construction.

The thermostat has a pin button marked R, allowing you to reset the thermostat to factory settings. These are listed at the end of this manual with space for
you to record your own weekly schedule.

GFCI

Test

R

Reset

®

BR928A08

A

B

C

D

E

F

H

I

G

Buttons

Display symbols

P

O

N

M

J

K

L

1. Getting started

Wake

Night

Out

Home

A:
Reset of GFCI

F:
Reset to factory 
setting

G: 
Adjustment down

H:
OK - accept

I: 
Adjustment up

B:
Red light 
indicating 
ground fault

C:
Test of GFCI

D:
Pin button 
adjust of clock

E:
Display

J:
Clock 
function

K:
Manual 
mode

L:
Time and 
temperature

M:
Day 
number

N:
Heating on

O: 
Monitoring of 
switch-on time

P:
4-event
symbol:

Setting the thermostat into operation

1-7

Press the UP (

) or DOWN (

) buttons to

select the correct time and press OK button (

).

Then press the UP (

) or DOWN (

) button to

select the correct day and press OK (

) button. 

Press the UP (

) button to select time and

temperature scale and press OK (

) button. 

First time power is connected the clock and day will be flashing and must be set. After setting of time and day, selection of time scale (12 h or 24 h) and
temperature scale (°C or °F) can be selected. If you need to adjust the time of the thermostat at a later date, insert a pin into the hole (

) for setting of time and

day. Adjustment must be made for summer and winter time. Setting of time and temperature scale can also be done under "advanced settings and read-out see 4.

Lagernummer: 57611 08/03 - (BJ)