background image

QUICK START GUIDE
GUIDE DE DÉMARRAGE RAPIDE
GUÍA DE INICIO RÁPIDO

CLASSIFICATION

The product is a Class II device (reinforced insulation) and must be 

connected to the following leads:

•  Phase L1 (L) 120 V

•  Neutral L2 (N) 0/120 V

•  Max. load 15 A (resistive load)

•  The Thermostat is to be used with underfloor heating.

The terminals are suitable for field wiring cables of 12 to 22 AWG.  

Heating element in accordance with the supply voltage.

TECHNICAL DATA

Supply Range .................................................... 120/240 Vac 50/60 Hz

Load  .............................................................max. 15 A (resistive load)

Max. power at e.g. ..................................................1800 W at 120 Vac

 ................................................................................3120 W at 208 Vac

 ................................................................................3600 W at 240 Vac

GFCI  ..............................................................  Class A (5 mA trip level)

Temperature range  ................................ +5 to +40°C  / +41 to +104°F

Amb. temp. range   ......................................0 to +25°C  / +32 to +77°F

WIFI . ........................................................................IEEE 802.11 b/g/n

Contains FCC ID .. ...................................................S67WSDE-670GN

Contains IC ID  ...................................................11069A-WSDE670GN

CERTIFICATION

UL Listed for the US and Canada

According to the following standards:

Thermostat:   UL 60730-1
 

UL 60730-2-9

 

CSA E60730-1:13

 

CSA E60730-2-9

UL file number: E157297 
GFCI:  

UL 943 4th ed.

CSA C22.2        No. 144.1-06 

Patent pending.

HOME SCREEN / ÉCRAN D’ACCUEIL / PANTALLA INICIAL

WARNINGS:

To avoid electric shock, disconnect the heating system power supply 

at the main panel before installation and maintenance of the thermo-

stat. Keep thermostat air vents clean and free from obstruction. This 

thermostat is an electrical device and must be installed in compli-

ance with national and/or local electrical codes. Installation must be 

performed by qualified personnel where required by law.

AVERTISSEMENTS :

Pour éviter l’électrocution, coupez l’alimentation du système de 

chauffage au panneau principal avant de faire l’installation et/ou 

l’entretien du thermostat. Maintenez les évents du thermostat propres 

et libres d’obstruction. Ce thermostat est un appareil électrique et 

doit être installé conformément aux codes électriques nationaux et/

ou locaux. L’installation doit être effectuée par du personnel qualifié 

quand la loi l’exige.

ADVERTENCIAS:

Para evitar descargas eléctricas, desconecte el suministro de alimen-

tación eléctrica del sistema de calefacción en el panel principal antes 

de

 la instalación y el mantenimiento del termostato. Mantenga limpios y libres 

de cualquier obstrucciones los orificios de ventilación de aire del termostato. 

Este termostato es un dispositivo eléctrico y debe instalarse de conformidad 

con los códigos eléctricos nacionales y/o locales. La instalación debe ser reali-

zada por personal cualificado donde así lo requiera la ley.

67432A 06/15 (JRK)

OJ Electronics A/S

Stenager 13B

DK-6400 Sønderborg

© 2015 OJ Electronics. All rights reserved.

This manual and parts thereof are protected under Danish and international copyright laws.

© 2015 OJ Electronics. Tous droits réservés.

Ce manuel et son contenu so

nt protégés par les lois internationales et danoises sur les 

droits d’auteur. 

© 2015 OJ Electronics. Reservados todos los derechos.

Este manual y partes del mismo están protegidas en virtud de las leyes danesas e 
internacionales sobre derechos de propiedad intelectual.

UWG4

  

WiFi Touch Thermostat

For support please contact your installer or retailer.

Pour le soutien, com

muniquez avec votre installateur ou votre détaillant. 

Para obtener soporte

 técnico, comuníquese con su instalador  

o con el vendedor minorista. 

www.ojelectronics.com/UWG4-download

Scan the QR-code for full user manual. 

Scannez le code QR pour obtenir le manuel complet de 

l’utilisateur.

Escanee el código QR para obtener el manual de 

usuario completo.

© 2015 OJ Electronics A/S · ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S  

Distributor ID:

 ___________________________________

1

3

4

5

7

9

2

6

10

11

CLASIFICACIÓN

El producto es un dispositivo Clase II 

(isolation renforcée)

 y debe ser 

conectado a los conductores siguientes:

•  Fase L1 (L) 120 V

•  Neutro L2 (N) 0/120 V

•  Carga máxima 15 A (carga resistiva)

•  El termostato está destinado a ser utilizado con calefacción por 

suelo radiante.

 

Los terminales son adecuados para cables de cableado de campo,  

calibre 12 a 22 AWG. Elemento calefactor de conformidad con el  

voltaje de suministro.

DATOS TÉCNICOS

Rango alimentación eléctrica ......................... 120/240 V CA, 50/60 Hz

Carga  ..........................................................máx. 15 A (carga resistiva)

Potencia maxima en el ejemplo  .............................1800 W a 120 V CA

 ...............................................................................3120 W a 208 V CA

 ...............................................................................3600 W a 240 V CA

GFCI  ..................................................  Clase A (nivel de disparo 5 mA)

Rango de temperatura  .............................+5 a +40 °C / +41 a +104 °F

Rango de temperatura ambiente .................. 0 a +25 °C / +32 a +77 °F

WIFI . ........................................................................IEEE 802.11 b/g/n

Contiene FCC ID ......................................................S67WSDE-670GN

Contiene IC ID . ..................................................11069A-WSDE670GN

CERTIFICACIÓN

En lista de UL para EE. UU. y Canadá

De conformidad con las normativas siguientes.
Termostato:  

UL 60730-1

 

UL 60730-2-9 

                                          CSA E60730-1:13
 

CSA E60730-2-9

Número de archivo UL:   E157297
GFCI: 

UL 943 4ta. edición

CSA C22.2  

No. 144.1-06 

Pendiente en trámite.

CLASSIFICATION

Le produit est un appareil de classe II (isolation renforcée) et doit être 

raccordé aux fils suivants :

•  Phase L1 (L) 120 V

•  Neutre L2 (N) 0/120 V

•  Charge maximum 15 A (charge résistive) 

•  Le thermostat est conçu pour être utilisé avec des planchers chauf-

fants

.

Les borniers sont adéquats pour du câble de construction de 12 à 22 

AWG. Élément chauffant en fonction de la tension d’alimentation.

DONNÉES TECHNIQUES

Plage alimentation  ........................................... 120/240 VCA 50/60 Hz

Charge  ......................................................Max. 15 A (charge résistive)

Puissance maxi par exemple au ..............................1800 W à 120 VCA

 ................................................................................3120 W à 208 VCA

 ................................................................................3600 W à 240 VCA

DDFT  ......................................  Class A (niveau déclenchement 5 mA)

Plage de température  ..............................+5 à +40 °C / +41 à +104 °F

Plage temp. amb. ......................................... 0 à +25 °C / +32 à +77 °F

WIFI  ........................................................................ IEEE 802.11 b/g/n

Contient FCC ID  ......................................................S67WSDE-670GN

Contient IC ID .....................................................11069A-WSDE670GN

CERTIFICATION

Homologué UL pour É.-U. et Canada

Selon les normes suivantes :

Thermostat:   UL 60730-1
 

UL 60730-2-9

 

CSA E60730-1:13

 

CSA E60730-2-9

UL file number: E157297 
GFCI:  

UL 943 4th ed.

CSA C22.2        No. 144.1-06 

En instance de brevet.

10

11

ITEMS / RÉF. / ELEMENTOS

Day and time

Jour et heure

Día y hora

Current temperature

Température actuelle

Temperatura actual

Heating indicator - when visible, system is heating.

Indicateur de chauffage - quand visible, chauffage en marche.

Indicador de calefacción; al estar visible, el sistema está calentando

Wireless connection indicator – see the manual for explanations

Indicateur de connexion sans fil – voir le manuel pour explications

Indicador de conexión inalámbrica – consultar las explicaciones en 

el manual

Access Main Menu

Accès menu principal

Acceder al menú principal

Weather indication – see the manual for explanations

Indication météo – voir le manuel pour explications

Indicación del clima – consultar las explicaciones en el manual

Target temperature or setpoint

Température cible ou point de consigne

Temperatura objetivo o punto de ajuste

9

Next scheduled change

Prochain changement prévu 

Próximo cambio programado 

GFCI Test Button

Bouton d’essai DDFT

Botón de prueba del GFCI

GFCI Indicator

Indicateur GFCI

Indicador GFCI

On/Off/GFCI Reset Button

Press to turn system ON

Hold toturn system OFF

Press to reset the GFCI

Bouton de réarmement, marche/arrêt/DDFT

Appuyez pour mettre en marche le système

Tenez pour fermer le système

Appuyez pour réarmer le DDFT

Encendido/apagado/botón de restablecimiento del GFCI

Pulsar para encender (ON) el sistema

Pulsar sin soltar para apagar (OFF) el sistema

Pulsar para restablecer el GFCI

6

7

8

2

1

3

4

5

8

Reviews: