background image

BV1250

Internet Voice Gateway

T

ECHNICAL 

R

EFERENCE

Oki Electric Industry Co., Ltd.

Summary of Contents for BV1250

Page 1: ...BV1250 Internet Voice Gateway TECHNICAL REFERENCE Oki Electric Industry Co Ltd...

Page 2: ......

Page 3: ...Safety Warning This document contains information relating to the safe installation maintenance and use of the Oki BV1250 Carefully note all safety precautions and procedures contained in this documen...

Page 4: ...thout notice The contents of this document and the Maintenance Console Software have been prepared with the utmost care However if you notice an ambiguous point or omission please contact an authorize...

Page 5: ...uality and functionality of the Maintenance Console Software and this Installation Guide Oki Electric holds no liability for the conformity of the equipment to the purpose of use by the user and the m...

Page 6: ...BV1250 Technical Reference Page iv Rev 1 0...

Page 7: ...BV1250 Maintenance and Troubleshooting BV1250 Maintenance and Troubleshooting BV1250 Maintenance and Troubleshooting 1 1 1 1 1 Routine Maintenance 3 1 1 External Cleaning 3 1 2 Periodic inspection 4...

Page 8: ...Notation 5 1 5 Response Messages 5 1 6 Continuous Mode and Page Mode Display 6 2 Utility Commands 7 3 Common Error Numbers for Maintenance Commands 9 4 Command Summaries 11 5 Command Descriptions 19 5...

Page 9: ...e compression encoding that can be configured on a priority basis to automatically select between 64kbps PCM stream as either G 729A 8kbps G 723 1 5 3kbps or G 723 1 6 3kbps compression packet priorit...

Page 10: ...Description BV1250 Technical Reference Page 2 Rev 1 0...

Page 11: ...Temperature range 0o C to 40o C Compliance Safety US UL1950 cUL950 JPN JEIDA EU CE Mark EMC US FCC part15 ClassA ICES 003 ClassA JPN VCCI ClassA EU CE Mark Redundancy Single Voice Compression Protoco...

Page 12: ...27 1999 Canadian Approval CS03 Model Name EMIF E M Certification No 187 9837 A FXS option Component PCB board Terminal Analog Telephone or Key Telephone System Lines 4 maximum Channels 4 simultaneous...

Page 13: ...he only difference between unit configurations is that the line interface connector ports appearing on the front panel vary between FXS FXO E M and E M OD equipped units These differences are noted in...

Page 14: ...front and rear panels have various physical elements associated with supplying power to the unit and providing operational status information Figure 2 2 illustrates these features These features are...

Page 15: ...F 6 Link lamp Indicates LAN link is operating normally when lit Green lamp 7 Uplink connector 10BaseT connector for LAN RJ45 9 Collision lamp Indicates frame collisions are occurring when lit Yellow l...

Page 16: ...01 4YA1158 1142G001 4YA1158 1143G001 4YA1158 1145G001 4YA1158 1125G001 BV1250 Rack Mount Kit 100106 4YA1158 1122G001 Maintenance Console Software 103012 BV1250 Installation Guide BV1250 Technical refe...

Page 17: ...ed personnel General maintenance activities include routine checks of data logs maintained in the unit s log files system file updates and should it becomes necessary the replacement of the unit s fus...

Page 18: ...Maintenance and Troubleshooting BV1250 Technical Reference Page 2 Rev 1 0...

Page 19: ...ich can interfere with the proper cooling of the unit and can affect the operation of the unit s external switches and buttons External cleaning is performed using a cloth dampened with a mild soapy s...

Page 20: ...m or the on line REBOOT command After restart repeat Step 1 this table Red ALARM lamp not lit All lamps are operating e g PWR CONT PP FAX and FAN Use the MCS Fault Log display or enter the on line ELO...

Page 21: ...em data file 3 0 VHUB OFD Each BV1250 has an office data file OFDD VHO which resides in the directory C Program Files Cons50 DATA Group_Name Unit_Name This file contains unit specific configuration in...

Page 22: ...Maintenance and Troubleshooting BV1250 Technical Reference Page 6 Rev 1 0...

Page 23: ...t in the diagnosis and correction of the problem The recommended procedure involves the following steps 1 Retrieve the unit s trouble log 2 Analyze the fault information 3 Identify the fault location...

Page 24: ...should be made Important elements of the report include the unit identification location information time of the event symptoms of the event and conditions use under which the event occurred In addit...

Page 25: ...aintenance Console Software IP address gateway address or subnet address wrong Incorrect cable connection Correct address es Inspect cable for damage and type and reconnect Replace cable if required N...

Page 26: ...fault log report ELOG There are 003 Messages 10 Remove 20 Voice 00 DSP Fault SEQ 01 TUE Jan 06 12 29 30 1998 4EF94000 15784E71 009029D0 009029D0 N xNq 00 Fault 20 Voice 00 DSP Fault SEQ 01 TUE Jan 06...

Page 27: ...Term 00 Terminal information not registered On Register terminal information and restart system 09 Report NonSYD 00 No system data On Transfer system files 0A Report BadSYD 00 System data error On Tra...

Page 28: ...LancUplink 00 Up link fault Status hold Check Cable or Network equipment 03 00 SIO Fault SIO_NG 00 SIO fault Status hold Serial communications failed Contact customer service 04 00 MTM Fault Restore M...

Page 29: ...sive traffic on network Try call later 04 Report VCL_ERROR 00 03 Voice communications error Status hold Excessive traffic on network Try call later 30 01 FAX Report FaxError 00 Fax communication error...

Page 30: ...the system reboot A trap message is output using the fields shown in Table 3 1 Table 3 1 Trap messages Field Type Value Version INTEGER O SNMP Version1 community OCTET STRING public enterprise OBJECT...

Page 31: ...ergency maintenance mode startup Yes 1280 No See Table 2 2 Code 00 05 No office data Yes 16778752 No See Table 2 2 Code 00 06 Office data error Yes 16779008 No See Table 2 2 Code 00 07 Terminal inform...

Page 32: ...68828672 See Table 2 2 Code 06 00 TSW Loop test failed Yes 1048576 1048579 No See Table 2 2 Code 10 00 DPRAM Self diagnostic failed Yes 1179648 Yes 269615104 See Table 2 2 Code 12 00 PP PKG PP fault H...

Page 33: ...the ITU T Rec T 30 for fax communication The chances that this will occur vary based upon type of G3 fax machines in use and the general configuration of the network If the automatic paper cut functio...

Page 34: ...ure described in the BV1250 Installation Guide Section 4 9 To replace a fuse 1 Unplug the unit s power cord from the power outlet 2 Pull the fuse holder assembly out from the rear panel of the unit 3...

Page 35: ...off to prevent excessive heat build up The unit should not be power up again until the fan has been replaced NOTE Before replacing the fuse turn the power to the unit OFF taking care to use the Power...

Page 36: ...the fan guard fan and fan fixing plate 8 Reverse the process described in step 7 above to install the new fan subassembly 9 Reconnect the fan connecting cable to the Main Board 10 Reconnect the power...

Page 37: ...he OUP command Action Follow the installation procedure to fully reconfigure the unit s OFDD VHO file correcting the unit s addressing scheme See BV1250 Installation Guide Section 5 7 for details Date...

Page 38: ...seconds Cause It is likely that the unit and PBX trunk parameters are in conflict For example the unit is configured for Immediate start but the PBX trunk is configured for Delayed start Action Refer...

Page 39: ...Since only one is present the call cannot be processed Action Check the DNSSEANUM value for calling BV1250 unit and change it to match the smallest number of digits used for a network Office Code See...

Page 40: ...tion Ensure that all unconnected ports are configured as disabled in the unit s OFDD VHO file See BV1250 Installation Guide Section 5 9 1 for details When calling a unit fast busy tone is returned and...

Page 41: ...ink start from an FXS FXO or E M unit the called unit s BUSY lamp illuminates and a fast busy tone is returned When calling an E M unit connected to a PBX using Immediate or Delayed start no activity...

Page 42: ...Symptom Units connected to the network through an Ethernet switch using an ARP cache outgoing calls can be placed but cannot receive incoming calls Cause If an Ethernet switch using an ARP cache is co...

Page 43: ...ation TCP UDP ports used by BV1250 must be opened in Firewall rules Ports must be opened for both input and output detection Source ports for TCP UDP packets must be configured as Random port numbers...

Page 44: ...e telephone set the vice volume is too low or the voice sounds distorted and has echo Cause The gain setting parameter PAD VALUE in the unit s OFDD VHO file is incorrectly configured Action If the voi...

Page 45: ...On line Command Reference The on line commands described in this reference allow remote control of the BV1250 through a simple text line interface For experienced users this interface can be used to q...

Page 46: ...On line Commands BV1250 Technical Reference Page 2 Revision 1 0...

Page 47: ...r programming personnel to integrate BV1250 IVG control and management functions into legacy Network Management Systems This reference is divided into the following sections 1 Command Overview 2 List...

Page 48: ...In most cases the SET GET and RST Reset argument is used to enter one or more configuration parameters into a BV1250 unit When these commands are used two values are returned through the on line inter...

Page 49: ...mber indicating the order in which the parameter is entered in the command line e g P1 P2 and P3 In some cases when describing a command in which an alpha numeric input is required the input requireme...

Page 50: ...n 00 If too few parameters were entered the parameter number returned is the number of input parameters plus 1 If too many parameters were entered the parameter number returned is the maximum number o...

Page 51: ...Date and time set display command 10 echo Command to output augments to standard output 11 setenv Command to set environment variables 12 getid Command to get user ID and group ID from Network File S...

Page 52: ...setid Command to set user ID and group ID to NFS Network File System 35 setpri Set task priority command 36 sleep Command to sleep execution of process of a specified time 37 suspend Command to do a t...

Page 53: ...rameter expression format error Improper characters used Values out of range Equipment name error 0016 Parameter digits number error Too few or too many characters or digits in the parameter 0018 Exec...

Page 54: ...On line Commands Command List BV1250 Technical Reference Page 10 Revision 1 0...

Page 55: ...ch start digits Get GET DNS SERNUM None 1 5 DNS TIME DNS access time Set SET DNS TIME P1 Start time time of day P2 Access period hours Get GET DNS TIME None 1 6 DNS VER DNS version Set SET DNS VER P1...

Page 56: ...Set SET TONE P1 Tone Type 1 to 8 P2 Tone Type 1 to 17 and 100 P3 Customized tone parameter Get GET TONE None 1 17 TRP COMMU Community name when trap is sent Set SET TRP COMMU P1 Community name Get GE...

Page 57: ...number P2 No password code Get GET DID ID NO P1 Port number Reset RST DID ID NO P1 Port number 3 5 DIL FXO Only DIL phone numbers Set SET DIL P1 Port number P2 Daytime number P3 Nightime number Get G...

Page 58: ...GET TRKROU P1 Hunt group number Reset RST TRKROU P1 Priority P2 Priority 3 14 VOICESP Voice access code Set SET VOICESP P1 Access code number Get GET VOICESP None Reset RST VOICESP None Line Informati...

Page 59: ...mber 4 9 TERM FXS Only Individual line data Set SET TERM P1 Port number P2 Extension no P3 Terminal category P4 Extension class fixed Get GET TERM P1 Port number Reset RST TERM P1 Port number 4 10 TRK...

Page 60: ...tup timeout Get GET NOCTIME None 8 5 RTCPINFO RTCP information Get RTCPINFO P1 Port number 8 6 RTP HEAD Voice RTP protocol Set SET RTP HEAD P1 Port number P2 RTP type H 323 or Oki Get GET RTP HEAD P1...

Page 61: ...e Information Command DLD Download value of individual trunk line EM Set Get Rst 4 5 Line Information Command DNS IP DNS IP address Set Get Rst 1 3 Equipment Command DNS SERNUM DNS search start digit...

Page 62: ...TP addresses Set Get Rst 1 14 Equipment Command SNMP TRPDST Community name when sending a trap Set Get Rst 1 15 Equipment Command SPD Speed dial numbers FXO Set Get Rst 3 11 Numbering Plan Command TER...

Page 63: ...escriptions The command groups described in this section are 5 1 Equipment Commands 5 2 Maintenance Console Commands 5 3 Numbering Plan Commands 5 4 Line Information Commands 5 5 Management Commands 5...

Page 64: ...On line Commands Command Descriptions BV1250 Technical Reference Page 20 Revision 1 0...

Page 65: ...g commands are described 1 1 AREA SET and GET 1 2 AUDIO CAP SET GET and RST 1 3 DNS IP SET GET and RST 1 4 DNS SERNUM SET and GET 1 5 DNS TIME SET and GET 1 6 DNS VER SET and GET 1 7 EMAIL ADR SET GET...

Page 66: ...On line Commands Equipment BV1250 Technical Reference Page 22 Revision 1 0...

Page 67: ...epresenting one of three possible settings US United States EU European and JP Japan Output Parameter s Displays current ACT and new SBY parameters for Tone class setting and individual parameters for...

Page 68: ...6 SBY_TONE_ROT 100 CROT TONE 8 ACT_TONE_HWT 7 SBY_TONE_HWT 7 SET AREA Command End Thu Feb 12 17 00 23 1998 GET AREA GET AREA ACT Zone JP SBY Zone US 1 ACT_TONE_DT 1 SBY_TONE_DT 8 2 ACT_TONE_RBT 2 SBY...

Page 69: ...3 P2 Input for low priority audio capability entered as a value of 1 to 3 Value Audio capability Bandwidth kbps 1 G 729A 8 0 2 G 723 1 6 3 3 G 723 1 5 3 Output Parameter s Displays current ACT and ne...

Page 70: ...T Audio Capability 1 2 SBY Audio Capability 3 1 GET AUDIO CAP Command End Thu Jan 30 17 54 23 1999 RST AUDIO CAP RST AUDIO CAP ACT Audio Capability 3 1 SBY Audio Capability 1 2 RST AUDIO CAP Command E...

Page 71: ...IP format which consists of numeric values separated by period in the range of 0 255 in decimal notation where the range is nnn when the IP address is nnn nnn nnn nnn Output Parameter s Displays curr...

Page 72: ...3 1996 GET DNS IP GET DNS IP ACT External DNS_IP_1 133 149 216 203 SBY External DNS_IP_1 133 149 216 103 ACT External DNS_IP_2 133 149 216 204 SBY External DNS_IP_2 133 149 216 104 ACT External DNS_IP...

Page 73: ...er s Displays current ACT and new SBY parameters as start digits 1 to 32 GET DNS SERNUM Returns the current setting for the DNS start digits Input Parameter s None Output Parameter s Displays current...

Page 74: ...o 24 hours Output Parameter s Displays current ACT and new SBY parameters for DNS start and access times GET DNS TIME Returns current DNS access and cycle time settings in the BV1250 Input Parameter s...

Page 75: ...ACT and new SBY parameters returned as version numbers 1 or 2 GET DNS VER Returns current DNS server version number Input Parameter s None Output Parameter s Displays current ACT and new SBY paramete...

Page 76: ...andard mail address ex BV1250 okint com max 64 characters P2 Input for E mail address 2 entered in standard mail address ex BV1250 okint com max 64 characters Output Parameter s Displays current ACT a...

Page 77: ...nd Thu May 28 17 00 23 1999 GW GET EMAIL ADR GET EMAIL ADR ACT EMAIL Address1 Tokyo okisiba co jp SBY EMAIL Address1 Tokyo oki co jp ACT EMAIL Address2 OOSAKA okisiba co jp SBY EMAIL Address2 OOSAKA o...

Page 78: ...ed 1 calls will be processed Output Parameter s Displays current ACT and new SBY parameters GET FAN FLT Input Parameter s None Output Parameter s Displays current ACT and new SBY parameters ACCESS SET...

Page 79: ...address is nnn nnn nnn nnn In the case of the BV1250 the Gateway address is usually the address of the Router to which the unit is connected Output Parameter s Displays current ACT and new SBY parame...

Page 80: ...nd TUE May 25 12 41 09 1999 GW RST GK IP RST GW IP ACT_GK_IP 133 149 216 101 SBY_GK_IP RST GK IP Command End Thu May 28 17 00 23 1996 GET GK IP GET GK IP Gatekeeper 1 ACT IP Address SBY IP Address Gat...

Page 81: ...ddress is nnn nnn nnn nnn In the case of the BV1250 the Gateway address is usually the address of the Router to which the unit is connected Output Parameter s Displays current ACT and new SBY paramete...

Page 82: ...1 ACT IP Address 133 149 216 101 SBY IP Address RST GW IP Command End Thu May 28 17 00 23 1996 GET GW IP GET GW IP Gateway 1 ACT IP Address 133 149 216 101 SBY IP Address 133 149 216 103 GET GW IP Co...

Page 83: ...eriod in the range of 0 255 in decimal notation Range of nnn when the IP address is nnn nnn nnn nnn GET IP Returns current IP address of a BV1250 Input Parameter s None Output Parameter s Returned val...

Page 84: ...AC address of BV1250 CHARACTERISTICS GET MAC ADR Returns MAC address of a BV1250 Input Parameter s None Output Parameter s Displays current MAC address in standard notation e g 8 0 20 lf d4 le ACCESS...

Page 85: ...BUFFER Input Parameter s None Output Parameter s Displays current ACT and new SBY parameters ACCESS SET RX BUFFER RS 232C and LAN GET RX BUFFER RS 232C and LAN EXAMPLE S SET RX BUFFER nnnn nnn nnn SET...

Page 86: ...or SMTP server IP addresses Addresses displayed in standard IP format which consists of numeric values separated by period in the range of 0 255 in decimal notation Range is nnn when the IP address is...

Page 87: ...TP ADR GET SMTP ADR SMTP Address 1 ACT IP Address 192 168 10 23 SBY IP Address 192 168 10 11 SMTP Address 2 ACT IP Address 192 168 10 24 SBY IP Address 192 168 10 15 GET SMTP ADR Command End Thu May 2...

Page 88: ...n the range of 0 255 in decimal notation Range is nnn when the IP address is nnn nnn nnn nnn Output Parameter s Displays current ACT and new SBY parameters for SNMP trap IP addresses Addresses display...

Page 89: ...mmand End Thu May 28 17 00 23 1996 RST SNMP TRPDST GET SNMP TRPDST ACT SNMP TRAP 1 133 149 216 203 SBY SNMP TRAP 1 133 149 216 103 ACT SNMP TRAP 2 133 149 216 204 SBY SNMP TRAP 2 133 149 216 104 ACT S...

Page 90: ...all end 5 Service tone Special dial tone SDT Receive number 6 Connection tone Connect tone CON Sending digits Connecting 7 Control tone Restricted Outward Tone ROT Connection control Wrong dial 8 Cont...

Page 91: ...C 3 SBY_TONE_DSC 3 5 ACT_TONE_SDT 4 SBY_TONE_SDT 4 6 ACT_TONE_CON 5 SBY_TONE_CON 5 7 ACT_TONE_ROT 6 SBY_TONE_ROT 100 CROT TONE 8 ACT_TONE_HWT 7 SBY_TONE_HWT 7 GET TONE Command End Thu Feb 12 17 00 23...

Page 92: ...ROT 400 Single 16 200 ON 200 OFF 200 ON 400 OFF 7 JP HWT US HWT EU HWT 2000 Single 0 100 ON 100 OFF 8 US DT US DSC 350 440 Composite 13 13 Continuous tone 9 US RBT 440 480 Composite 19 19 2000 ON 400...

Page 93: ...an Tone Class Frequency Interval value mSec Level Parameter 1 Parameter 2 DT 400 250 ON 250 OFF 16 1 1 RBT 400 20 1000 ON 2000 OFF 13 2 2 BT 400 500 ON 500 OFF 16 3 3 DSC 400 500 ON 500 OFF 16 4 3 SDT...

Page 94: ...OMMU Returns current community name for trap transmission Input Parameter s None Output Parameter s Displays current ACT and new SBY parameters for community name ACCESS SET TRP COMMU RS 232C and LAN...

Page 95: ...se letters and lower case letters are not differentiated A name must start with an alpha character and may not end with a hyphen Output Parameter s Output values for current ACT and new SBY parameters...

Page 96: ...28 17 00 23 1996 GET VBM DOMAIN GET VBM DOMAIN ACT Domain Name Tokyo oki_siba co jp SBY Domain Name Tokyo oki co jp GET VBM DOMAIN Command End Thu May 28 17 00 23 1996 RST VBM DOMAIN RST VBM DOMAIN AC...

Page 97: ...s nnn nnn nnn nnn The IP address of the BV1250 is also returned GET VBM SUBNET Returns current subnet address of a BV1250 Input Parameter s None Output Parameter s Returned values for current ACT and...

Page 98: ...5 2 Maintenance Console Commands Maintenance Console commands are used to configure user access manage on line sessions and obtain on line help for commands The following commands are described 2 1 DI...

Page 99: ...nd new SBY configuration parameters Input Parameter s None Output Parameter s Displays difference data between current ACT and new SBY parameters for BV1250 unit ACCESS HELP or RS 232C and LAN EXAMPLE...

Page 100: ...ist of command names displayed when no parameter is specified Input Parameter s P1 Command name Output Parameter s Returns parameter description summary for the command specified as an input parameter...

Page 101: ...FUNCTION Commands to log out from Maintenance Console Software CHARACTERISTICS Logout Ends session and terminates serial or Telnet connection Input Parameter s None Output Parameter s None ACCESS LOG...

Page 102: ...splays current display mode e g List Mode 0 Overrun or List Mode Page By Page GET LST MOD Returns current terminal output Input Parameter s None Output Parameter s Displays current display mode e g Li...

Page 103: ...P3 Query New Password requires confirmation verification of new password P2 Output Parameter s None see errors ACCESS SET PASS M RS 232C and LAN EXAMPLE S SET PASS M10 SET PASS M Old Password New Pass...

Page 104: ...Password requires confirmation verification of new password P2 Output Parameter s None see errors ACCESS SET PASS U RS 232C and LAN EXAMPLE S SET PASS U11 SET PASS U Old Password New Password New Pas...

Page 105: ...BV1250 Technical Reference Command Reference Maint Console Commands Revision 1 0 Page 61...

Page 106: ...ered are displayed as SBY until they are backed up in the unit using the OUP command and the unit is rebooted The following commands are described 3 1 ACPOSI SET and GET 3 2 DAYNIGHT SET GET and RST 3...

Page 107: ...SBY parameters for access code position GET ACPOSI Displays code for location position at which voice and fax access codes will be entered when dialing a number Input Parameter s None Output Paramete...

Page 108: ...2 GET DAYNIGHT Returns current Pattern Time s Input Parameter s P1 Optional ID Number 1 or 2 Omitting P1 returns current configuration If P1 1 then Pattern number range 1 8 If P2 2 then Date mmdd P2 O...

Page 109: ...ET DAYNIGHT 1 Pattern 1 ACT Daytime 0000 2400 SBY Daytime 0800 1700 Pattern 2 ACT Daytime 0000 2400 SBY Daytime 0000 2400 Pattern 3 ACT Daytime 0000 2400 SBY Daytime 0000 2400 Pattern 4 ACT Daytime 00...

Page 110: ...101 Cause Type value out of range Remedy Correct value and retry No 0102 Cause Pattern number value out of range Remedy Correct value and retry No 0103 Cause Time parameter value out of range Remedy C...

Page 111: ...t DISA setting for BV1250 FXO unit Input Parameter s P1 Optional port number 1 2 3 or 4 Omitting P1 returns all Output Parameter s Displays current ACT and new SBY DISA parameters for all ports on the...

Page 112: ...plays current ACT and new SBY parameters for configured port 1 2 3 or 4 GET DID ID NO Returns current DISA password for specified BV1250 FXO unit port Input Parameter s None Output Parameter s Display...

Page 113: ...SBY DID Id Number 1234 1234 Port 2 ACT DID Id Number SBY DID Id Number 1234 1234 Port 3 ACT DID Id Number SBY DID Id Number Port 4 ACT DID Id Number SBY DID Id Number GET DID ID NO Command End TUE Ma...

Page 114: ...d in P1 Output Parameter s Displays current ACT and new SBY forwarding number s for configured port 1 2 3 or 4 GET DID ID NO P1 Returns current DIL Day and Night forwarding numbers for specified BV125...

Page 115: ...No SBY Port 2 Day No Night No ACT Port 3 Day No 45317 Night No SBY Port 3 Day No 45317 Night No ACT Port 4 Day No 45317 Night No SBY Port 4 Day No 45317 Night No GET DIL Command End TUE May 25 14 21...

Page 116: ...symbols 12 Output Parameter s Displays current ACT and new SBY parameters for Fax Access Code GET FAXSP Returns current Fax Access Code Input Parameter s None Output Parameter s Displays current ACT a...

Page 117: ...CT Fax Access Code 5 SBY Fax Access Code 9 SET FAXSP Command End Thu Jan 30 18 19 23 1997 GET FAXSP GET FAXSP ACT Fax Access Code 5 SBY Fax Access Code 9 SET FAXSP Command End Thu Jan 30 18 19 23 1997...

Page 118: ...order when a call is received by port 1 1 4 3 2 Terminal hunt priority order when a call is received by port 4 4 3 2 1 The terminal hunt order is the same even if the port numbers 1 4 3 2 2 1 4 3 4 3...

Page 119: ...Command End TUE Mar 31 20 26 47 1998 RST HNT n RST HNT 1 Act Group 1 Port Sequence 3 2 1 4 SBY Group 1 Port Sequence GET HNT Command End TUE Mar 31 20 26 47 1998 ERRORS No 0101 Cause Terminal hunt gro...

Page 120: ...splays current ACT and new SBY parameters for Hunt pattern index pattern destination numbers and response time GET HNTPTN Displays current ACT and standby SBY Hunt pattern index pattern and destinatio...

Page 121: ...1 Hunt Ptn 1 Destination Number 99 Response Time 20 ACT Index 2 Hunt Ptn Destination Number Response Time SBY Index 2 Hunt Ptn 3 Destination Number 4085551212 Response Time 30 GET HNTPTN Command End...

Page 122: ...er s Displays current ACT and new SBY parameters for intra office office code GET PRE Displays intra office number office code for a BV1250 unit Input Parameter s None Output Parameter s Displays curr...

Page 123: ...nnnnn SET PRE 24 ACT_Prefix_Num 21 SBY_Prefix_Num 24 SET PRE Command End Fri Jan 31 10 48 23 1997 GET PRE GET PRE ACT_Prefix_Num 21 SBY_Prefix_Num 24 SET PRE Command End Fri Jan 31 11 04 23 1997 RST P...

Page 124: ...ximum per item for up to 32 items Output Parameter s Displays current ACT and new SBY restricted digits list GET RES NO Returns list of current defined restricted digits for BV1250 FXO unit Input Para...

Page 125: ...ACT Restriction Number SBY Restriction Number 1234 GET RES NO Command End TUE May 25 14 56 37 1999 GW RST RES NO nnnn RST RES NO 1234 ACT Restriction Number SBY Restriction Number RST RES NO Command...

Page 126: ...utput Parameter s Displays current ACT and new SBY Speed dial code and calling number GET SPD Returns list of currently defined Speed Dial codes and associated calling numbers Input Parameter s P1 Opt...

Page 127: ...TUE May 25 14 59 58 1999 GW GET SPD nn GET SPD ACT Spd Dial No 01 Dialed No SBY Spd Dial No 01 Dialed No 4085551212 GET SPD Command End TUE May 25 15 00 10 1999 GW RST SPD nn RST SPD 01 RST SPD Comman...

Page 128: ...as a number from 1 to 4 P2 Number of digits deleted entered as a number from 0 to 32 Output Parameter s Displays current ACT and new SBY parameters for Trunk number and number of digits to be deleted...

Page 129: ...Digits 3 SET TGN Command End Fri Jan 31 10 48 23 1997 GET TGN GET TGN ACT Trunk Group 1 Delete Digits 4 SBY Trunk Group 1 Delete Digits 3 GET TGN Command End Fri Jan 31 11 04 23 1997 ERRORS No 0101 Ca...

Page 130: ...d Trunk group numbers GET TRKROU Displays hunt pattern number priority number and trunk group number to BV1250 unit Input Parameter s P1 Hunt pattern number entered as a number from 1 to 4 All are dis...

Page 131: ...k Group Number Hntptn_Num 2 Priority 1 ACT Trunk Group Number 1 SBY Trunk Group Number 1 Priority 2 ACT Trunk Group Number 2 SBY Trunk Group Number 2 Priority 3 ACT Trunk Group Number SBY Trunk Group...

Page 132: ...mbols 15 Output Parameter s Displays current ACT and new SBY parameters for Voice Access Code GET VOICESP Returns current Voice Access Code Input Parameter s None Output Parameter s Displays current A...

Page 133: ...cess Code 5 SBY Voice Access Code 4 SET VOICESP Command End Thu Jan 30 17 54 23 1997 GET VOICESP GET VOICESP ACT Voice Access Code 5 SBY Voice Access Code 4 GET VOICESP Command End Thu Jan 30 17 54 23...

Page 134: ...OFDD VHO and is also used in DNS DAT file configuration All parameters entered are displayed as SBY until they are backed up in the unit using the OUP command and the unit is rebooted The following co...

Page 135: ...s GET AGC Input Parameter s P1 Port number 1 2 3 or 4 If omitted returns All Output Parameter s Displays current ACT and new SBY parameters ACCESS SET AGC RS 232C and LAN GET AGC RS 232C and LAN EXAMP...

Page 136: ...Page 92 Revision 1 0 ERRORS No 0101 Cause Port number out of range Remedy Correct value and try again No 0102 Cause Used AGC function value out of range Remedy Correct value and try again No 0103 Cau...

Page 137: ...ns no disconnect signal If P4 0 12 to 21 12 576ms 13 624ms 14 672ms 21 1008ms in multiples of 48ms If P4 1 8 to 17 8 384ms 9 432ms 10 480ms 17 816ms in multiples of 48ms P4 Type of disconnect signal e...

Page 138: ...l 0 SBY_Pulse_Signal 10 SBY_Signal_Id 0 GET AP SYSDLD Command End Thu Jan 30 17 54 23 1997 RST AP SYSDLD RST AP SYSDLD ACT_Ring_Freq 1 SBY_Ring_Freq 0 ACT_Ring_Inter 1 SBY_Ring_Inte 0 ACT_Pulse_Signal...

Page 139: ...iming restricts the use of the trunk for the specified number of seconds following the completion of a call in order to permit the PBX to reset the line Output Parameter s Displays current ACT and new...

Page 140: ...0 SBY Make Rate 0 ACT Reverse Timing 125 SBY Reverce Timing 125 ACT PrePause Timing 7 SBY Pre Pause Timing 7 ACT Guard Timing 5 SBY Guard Timing 5 Port 3 ACT Dial Speed 6 SBY Dial Speed 6 ACT Make Ra...

Page 141: ...ause DP DTMF value out of range Remedy Correct value and retry No 0103 Cause DP rate value out of range Remedy Correct value and retry No 0104 Cause Reverse timing value out of range Remedy Correct va...

Page 142: ...ACT and new SBY Disconnect value to BV1250 E M or FXO unit GET DISC Returns currently defined Disconnect value to BV1250 E M or FXO unit Input Parameter s None Output Parameter s Displays current ACT...

Page 143: ...lue see Delay Dial and Wink Start table below P4 Speed Record value see Speed Record table below P5 Guard timing Range 0 15 0 Not used 1 512ms 2 1024ms Guard timing restricts the use of the trunk for...

Page 144: ...t to send a called number When this method is used P3 must be fixed to 0 13 Use of the Wink Start method parameter P3 s determined by the requirements of the office equipment PBX used It is necessary...

Page 145: ...to 4 Output Parameter s Displays current ACT and new SBY parameters ACCESS SET DLD RS 232C and LAN GET DLD RS 232C and LAN RST DLD RS 232C and LAN EXAMPLE S SET DLD n n n n SET DLD 1 1 2 1 6 ACT Port...

Page 146: ...y Change value and retry No 0102 Cause Delay dial value out of range Remedy Correct value and retry No 0103 Cause Wink start pulse width out of range Remedy Correct value and retry No 0104 Cause Speed...

Page 147: ...50 unit Input Parameter s P1 Port number 1 2 3 or 4 P2 DTMF function where 0 Disabled 1 DTMF on call originating only 2 DTMF on call destination only 3 DTMF on both send and receive Output Parameter s...

Page 148: ...F GET DTMF ACT Port 1 DTMF function 1 SBY Port 1 DTMF function 1 ACT Port 2 DTMF function 1 SBY Port 2 DTMF function 1 ACT Port 3 DTMF function 1 SBY Port 3 DTMF function 3 ACT Port 4 DTMF function 1...

Page 149: ...ys current ACT and new SBY parameters GET LAW FLG Input Parameter s None Output Parameter s Displays current ACT and new SBY parameters ACCESS SET LAW FLG RS 232C and LAN GET LAW FLG RS 232C and LAN E...

Page 150: ...2 0 2 4 6 8 10 12 14 16 18 20 36 38 4017 P3 Down Outgoing Pad level entered as a gain loss number in dB i e 14 12 10 8 6 4 2 0 2 4 6 8 10 12 14 16 18 20 36 38 4018 Output Parameter s Displays current...

Page 151: ...B Down PAD Value 0dB ACT Port 2 Up PAD Value 0dB Down PAD Value 0dB SBY Port 2 Up PAD Value 0dB Down PAD Value 0dB ACT Port 3 Up PAD Value 0dB Down PAD Value 0dB SBY Port 3 Up PAD Value 10dB Down PAD...

Page 152: ...and reset line information even if a terminal hunt group has been previously registered using the SET HNT command Unused ports should not be defined Output Parameter s Displays current ACT and new SB...

Page 153: ...k_Num 1 SBY_Trunk_Num 1 Priority 2 ACT_Trunk_Num 2 SBY_Trunk_Num 2 Priority 3 ACT_Trunk_Num SBY_Trunk_Num Priority 4 ACT_Trunk_Num SBY_Trunk_Num continued GET TERM Command End Mon Jan 13 09 48 23 1997...

Page 154: ...A 1 DIL and 2 PBXIN Output Parameter s Displays current ACT and new SBY trunk line parameters for specified port GET TRK Displays current ACT and new SBY trunk line parameters for specified port Input...

Page 155: ..._Trunk_Group_Num 3 SBY_Trunk_Group_Num 2 Port_Num 4 ACT_Trunk_Group_Num 4 SBY_Trunk_Group_Num 3 Because the parameters are omitted continues for the port numbers GET TRK Command End Fri Jan 31 14 31 2...

Page 156: ...Commands Management BV1250 Technical Reference Page 112 Revision 1 0 5 5 Management Commands Management are used to obtain information about a BV1250 unit The following commands are described 5 1 USA...

Page 157: ...When P1 is entered as 1 displays unit fault information in hexadecimal notation See table below P1 Information Returned Omitted Fault Fault Unit no short 20 Voice etc Detail no short 00 DSP Fault etc...

Page 158: ...version level and type When P1 is entered as 1 returns version information for installed firmware and tone settings See table below P1 Information Returned Notes Omitted Unit type expressed as BV1250...

Page 159: ...PLE S VER n VER BV12500 System Vx xx AP VER Command End Thu May 28 17 00 23 1996 VER 1 BV1250 System Vx xx AP IPL Vx xx OS Vx xx OPL Vx xx COR Vx xx NET Vx xx MAS Vx xx CCL Vx xx VCL Vx xx DNS Vx xx H...

Page 160: ...echnical Reference Page 116 Revision 1 0 5 6 Report Commands Report commands are used to retrieve and manage a BV1250 unit s internal log files The following commands are described 6 1 ELOG 6 2 ELOG C...

Page 161: ...cludes ASCII code display NOTE The terminal display mode can be set by the SET LST MOD command to select between continuous and paged displays See the SET LST MOD command ACCESS ELOG RS 232C and LAN E...

Page 162: ...nd FUNCTION Command to clear fault log CHARACTERISTICS ELOG CLR Clears the fault log on the BV1250 unit Input Parameter s None Output Parameter s Displays confirmation of execution as ELOG CLR ACCESS...

Page 163: ...me Speech end time Speech time CODEC Fax identification C0 Codec no 0 C1 Codec no 1 C2 Codec no 2 C3 Codec no 3 F0 F3 Fax EX Extension E0 Fax extension Distinction between call origination sender and...

Page 164: ...interfaces don t match 23 T303 T301 time out Check network 24 Unexpected error recall after a while Try call later 25 Call end by Gatekeeper recall after a while Try call later 26 Remote terminal not...

Page 165: ...5 Received message content insufficient data Protocol error 11116 Requested unsupported function Called terminal does not support feature 11117 Received unsupported Q 931 message Called terminal does...

Page 166: ...office data 11406 Failed up link Check network 11407 Password error FXO Check office data enter correct password Table Disconnect from own Terminal Voice control Value Meaning Detail masure 12001 Dis...

Page 167: ...all after a while EXAMPLE S HIST 5 HIST 5 1997 05 17 Wed RECORD_COUNT 5 No Calling_Num Called_Num Dst_IP SDate STime EData ETime Ph_Time Kind S R Cause 1 2551 84004 10 77 168 33 05 22 18 52 2005 22 18...

Page 168: ...0 to 6 where 0 Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday and 6 Saturday When P1 is omitted call history file is deleted but data in memory remains intact until reboot unit restart or O...

Page 169: ...calls in the same unit ECp Number of completed calls in the same unit Fax EIp Number of incomplete calls in the same unit Fax LAN TEL Number of calls via LAN SCp Number of completed calls of calling...

Page 170: ...n nnn nnn nnn nnn nnn nnn 00 15 00 30 nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn nnn Continues TRF Command End Thu May 28 20 10 42 1996 TRF 3 1997 05 17 Wed Record Entries 96 SYSTEM E...

Page 171: ...1 0 Page 127 5 7 Maintenance Commands Maintenance commands are used to operate a BV1250 unit s file storage system and to shutdown and reboot the unit The following commands are described 7 1 DTY 7 2...

Page 172: ...e mmdd Use the digit 0 when a day or month value is single digit e g 0101 January 1 P3 Time entered in as a four digit number in 24 hour format in which the first two digits represent the hour and th...

Page 173: ...D VHS file is detected on the BV1250 unit unit requests confirmation to Overwrite Sure Y N Type Y for Yes or N for NO Y overwrites existing file ACCESS GERERATE SYSD RS 232C and LAN EXAMPLE S GENERATE...

Page 174: ...ered to the BV1250 unit to be written to the unit s office data file Input Parameter s None Output Parameter s Displays confirmation of the command as OUP ACCESS OUP RS 232C and LAN EXAMPLE S OUP OUP...

Page 175: ...d as 1 Force reboot Output Parameter s Displays a confirmation request Sure Y N When Y or y is entered if P1 1 displays confirmation of shutdown as Now BV1250 System Reboot if P1 omitted displays conf...

Page 176: ...wn the BV1250 CHARACTERISTICS SHUTDOWN Shuts down the BV1250 unit Input Parameter s None Output Parameter s Displays a confirmation request Sure Y N When Y or y is entered displays confirmation of shu...

Page 177: ...Log for Sunday Traffic information TRAFF LOG Call log CALL LOG Volume 3 3 Traffic and call Log for Monday Traffic information TRAFF LOG Call log CALL LOG Volume 3 4 Traffic and call Log for Tuesday Tr...

Page 178: ...ation messages and directory creation confirmation messages See practical Examples on following page ACCESS VOLINIT RS 232C and LAN EXAMPLE S VOLINIT 3 0 VOLINIT 3 0 Warning All Data on volume 3 0 wil...

Page 179: ...nce Rev 1 0 Page 135 Remedy Try again If error occurs frequently replace unit No 0104 Cause Directory creation failed Remedy Try again If error occurs frequently replace unit No 0105 Cause Initializat...

Page 180: ...On line Commands Maintenance BV1250 Technical Reference Page 136 Rev 1 0...

Page 181: ...s data file OFDD VHO All parameters entered are displayed as SBY until they are backed up in the unit using the OUP command and the unit is rebooted The following commands are described 8 1 CALL PORT...

Page 182: ...r GET CALL PORT Returns current call signaling port number Input Parameter s None Output Parameter s Displays current ACT and new SBY call signaling port number ACCESS SET CALL PORT RS 232C and LAN GE...

Page 183: ...turns TCP and UDP port address confirmation messages for all signaling channels ACCESS FIREWALL CHECK RS 232C and LAN EXAMPLE S FIREWALL CHECK FIREWALL CHECK 198 206 124 38 Sending TCP 53 Done Sending...

Page 184: ...245 PORT Returns current H 245 start TCP port number Input Parameter s None Output Parameter s Displays current ACT and new SBY H 245 start TCP port number ACCESS SET H245 PORT RS 232C and LAN GET H24...

Page 185: ...t ACT and new SBY call setup time out displayed in seconds GET NOCTIME Returns current call setup time out value for BV1250 unit Input Parameter s None Output Parameter s Returns values for current AC...

Page 186: ...arameter s P1 Optional port number 1 2 3 or 4 Omitting P1 returns summary data Output Parameter s For each port on the BV1250 unit returns Call Type Codec Number Start Time and Start Date ACCESS RTCPI...

Page 187: ...y defined RTP header type for the BV1250 unit Input Parameter s P1 Optional port number 1 2 3 or 4 Omitting P1 returns all Output Parameter s Displays current ACT and new SBY RTP header type for the B...

Page 188: ...TP PORT Returns current RTP start port number Input Parameter s None Output Parameter s Displays current ACT and new SBY RTP start port number ACCESS SET H245 PORT RS 232C and LAN GET H245 PORT RS 232...

Page 189: ...ignment information from BV1250 unit Input Parameter s None Output Parameter s Returns port assignments for BV1250 unit including DNS Q 931 H 245 RAS and RTP RTCP ACCESS GET TEST PORT RS 232C and LAN...

Page 190: ...ular Timing P3 Number of times that an error can be detected before the link is failed disconnected P4 Reconnect on Errors is number of times that a recovered link is to be detected before the link wi...

Page 191: ...value out of range Remedy Correct value and retry No 0102 Cause Error detect time period value out of range Remedy Correct value and retry No 0103 Cause Disconnect after errors value out of range Rem...

Page 192: ...bytes Output Parameter s Displays current ACT and new SBY Voice Condition parameter P1 GET VOICECOND Returns current Voice Condition parameter Input Parameter s None Output Parameter s Displays curren...

Page 193: ...onfigure a BV1250 FXO unit s interface with a PSTN and or PBX in the unit s data file OFDD VHO All parameters entered are displayed as SBY until they are backed up in the unit using the OUP command an...

Page 194: ...0 FXO unit Input Parameter s P1 Drop time in seconds set as value between 1 and 8 seconds Output Parameter s Displays current ACT and new SBY Speed dial code and calling number GET CO ATDRP Returns cu...

Page 195: ...ommand End TUE May 25 09 54 44 1999 GW GET CO ATDRP GET CO ATDRP ACT Auto Dropout Time 5 SBY Auto Dropout Time 5 GET CO ATDRP Command End TUE May 25 09 55 15 1999 GW RST CO ATDRP RST CO ATDRP ACT Auto...

Page 196: ...O unit Input Parameter s P1 Response time as a value between 0 and 10 seconds 0 disables the function Output Parameter s Displays current ACT and new SBY DISA response time for the FXO unit GET DID TI...

Page 197: ...eter s None Output Parameter s Displays current ACT and new SBY values ACCESS SET TONE DET RS 232C and LAN GET TONE DET RS 232C and LAN EXAMPLE S SET TONE DET n nnnn SET TONE DET 1 1500 ACT DT Detect...

Page 198: ...On line Commands FXO Interface BV1250 Technical Reference Page 154 Rev 1 0...

Reviews: