Water Tank
Pressure Valves
Before Turning On the Equipment:
Page 01 - 5403132 - R06
1A -
2A -
Deliv
er
y Sys
tem
Sprint Quick Operation Guide - Description of Parts and Controls of Equipment
Observe the Scheduled Review system for your equipment.
- Equipments made to last!
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
9 -
Zero Position
Work Position
Backrest Up ( )
Seat Down ( )
Backrest Down ( )
Seat Up ( )
On/Off Operating Light
Spittoon Bowl Flush
Progressive/Activation Pedal
Commands
1º - Check if the equipment is properly installed in accordance
with the instructions in
chapter 6
of the
User
Manual Dental Line
;
2º - Turn On the air compressor that supplies the equipment;
3º - Open the main water supply valve of the equipment;
4º - Turn On the equipment's power circuit breaker.
9
7
8
1
2
3
4
5
6
F03
Before using the equipment, please read the
User Manual Dental Line
carefully.
The purpose of this guide is to identify commands, parts, and instruments that may be available to the equipment, including optional items.
This guide does not define the equipment configuration that may vary according to the customer's request.
In case of loss of the
User Manual
and/or
Operation Guide
, please contact us by e-mail
informing the serial number of your equipment.
export3@olsen.odo.br
Operating Lights
Control Knob
Control Rod
Sensor
1 -
2 -
3 -
Seat Up/Position 1
Backrest Up/Position 2
Seat Down/Position 3
Backrest Down/Spit Position
Work Position
Zero Position
Progressive/Activation Pedal
Cup Filler
On/Off Operating Light
Spittoon Bowl Flush
Metal Handle
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
9 -
10 -
11 -
R
emot
e F
oot P
edal
1A
2A
Chair Base
1B -
2B -
On/Off Switch with LED Indicator
Fuse Holder
Turning On the Equipment:
1º - Turn On the On/Off switch;
2º - Activate the "Seat Up" command on the chair base until the
seat reaches its maximum height limit;
3º - Close the pressure valve;
4º - Remove the water tank and make sure it filled with water. If
necessary, fill it with drinkable water up to the limit indicated in
tank and reattach it again. If you wish, to place prophylactic
products (low concentration);
5 º - Open the pressure valve and check if the water tank is well
attached and free of leaks;
6º - Before starting the use equipment, verify the operation of all
instruments and commands available and perform the cleaning
and sterilization of the instruments.
Concept Plus
3
2
LED Premium
1
3
Evolution Plus
1° - To activate the Operating Light, press the
Operating Light On/Off button at the base of the
chair (section Commands - 7), this action also
enables the sensor (
3
) and the control button/
rod (
2
);
2° - To change the lighting intensity of the
Evolution Plus Operating Light, keep the
command button - Commands section (
7
) -
pressed for more than 2 seconds;
3° - To turn on or off the Concept Plus and LED
Premium Operating Light, pass your hand in
front of the sensor (
3
) at approximately 5 cm
distance or hold the control rod (
2
), in the case of
Concept Plus, or turn the control button (
1
), in the
case of the Premium LED spotlight;
4° - To change the lighting intensity of the
Concep Plus and Premium LED reflectors, keep
your hand in front of the sensor (
3
) or hold the control rod (
2
), in the case of Concept Plus or turn the control
knob (
1
), in the case of the Premium LED Operating Light.
To save a work position:
1º - Press the Zero Position button;
2º - Adjust the backrest to the desired position;
3º - Adjust the seat to the desired position;
4º - Press the Work Position button for 5 seconds. The equipment will emit 2 long beeps;
5º - Press command 1 (Seat Up) while the equipment beeps; The equipment will emit 2 short beeps to
confirm the procedure;
6º - Press the Zero Position button.
2
4
7
6
5
10
11
1
8
9
3
1B
2B