GR-312/15L
220-240V AC/50-60Hz
IP 40
3
,
6
V/1,5Ah
105lm
EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3
73
5
gr.
3
,
6
V/600mAh
3W /3VA
655gr.
GR-310/15L
Thank you for purchasing this product of
Olympia Electronics. A European manufacturer.
GENERAL
o
These luminaires are used indoors
(
ta 40 C
)
where emergency light is needed.
Each luminaire must be permanently connected
to mains power supply
.
In normal operation the battery is charging and
the 2 yellow LED’s light in the screen.
In case of a mains power supply failure the
luminaire will light the led strip automatically in
emergency mode. When the mains power
supply is restored the device turns to normal
operation.
MAINTAINED / NON-MAINTAINED
OPERATION
There is an option to select the maintained or
non-maintained operation by placing the jumper
to the appropriate place according to step 8
(page 4)
.
INSTALLATION
To install the luminaire follow the installation
instructions
ο
n page 4.
ΑΤΤΕΝΤΙΟΝ
!!!
1. Operations for installation, maintainance or
testing must be done by authorized personel
only
.
2.
The device must be connected to the mains
power supply thru a fuse dependent by the total
amount of the line’s power load
.
3.
It is sugested to check every month the
indication LED for battery charging, and by
p u s h i n g t h e T E S T b u t t o n t o c h e c k t h e
emergency circuit. The led strip should: a) light
with bigger intensity as long as the TEST button
is pressed (maintained operation),
b) light as long as the TEST button is pressed
(non-maintained operation).
4.
It is sugested to check every 6 months the
minimum autononous duration by disconnecting
the mains power supply
.
Count the time that the
led strip lights and in case of less time than the
minimum autonomous duration the battery must
b e r e p l a c e d . I f t h e m e a s u r e d t i m e i s
considerably less than the minimum autonomous
duration
In case of battery
or led strip replacement, these must be replaced
by parts of the same type, by the manufacturer
or by a competent person.
t i
in battery recycling
points.
Do not incinerate.
If the luminaire
doesn’t work as described above contact the
installer.
contact the installer.
5.
In case of inactive use for a period greater
than 2 months, disconnect the battery by pulling
out the battery’s connector.
6.
I
s not allowed to discard batteries in to
common trash bins, they must be
discarded only
TECHNICAL CHARACTERISTICS
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
CONSTRUCTION MATERIALS
TYPICAL WEIGHT
GUARANTEE
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES
(
Ni-Cd
)
CHARGING TIME
INDICATIONS
-
CONTROLS
BATTERY PROTECTION
MINIMUM AUTONOMOUS DURATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
EMERGENCY ILLUMINATION
ILLUMINATION SOURCE
24h
From overcharge and full discharge
15 white LED’s
Bayblend FR3010
,
transparent
polycarbonate
180min
0 to 40 C
o
Up to 95%
3 years
(1
year for the battery
)
90min
Page
1
from
4
Battery charging LED
,
TEST button
‘’
EASY LIGHT‘’ SERIES FOR NON-MAINTAINED
/ΜΑΙΝΤΑΙΝΕ
D
EMERGENCY LUMINAIRES
350
x 134 x 45 mm
(CRV 362 x 134 x 58 mm)
923312017_09_003