GENERAL

o

These  luminaires  are  used  indoors 

(

ta  40 C

)

 

on the wall, where emergency light is needed.
E a c h   l u m i n a i r e   m u s t   b e   p e r m a n e n t l y  
connected  to  mains  power  supply

.

  In  normal 

operation the illumination LEDs are lit as well 
as  the  green  indicating  charge  LEDs,  when 
the battery is charging. 
In  case  of  a  mains  power  supply  failure  the 
luminaire    will  light  the  led  strip  automatically 
in  emergency  mode.  When  the  mains  power 
supply  is  restored  the  device  turns  to  normal 
operation.

Non  Maintained  /  maintained  operation 

there is an option to select the non maintained 
or maintained operation by placing the jumper 
to  the  appropriate  place  according  to  the 
figure 3 (see page 2)

.

INSTALLATION

To  install  the  luminaire  follow  the  installation 
instructions on page 2.

ΑΤΤΕΝΤΙΟΝ

!!!

1. Operations for installation, maintainance or 
testing must be done by authorized personnel 
only

.

2. 

The  device  must  be  connected  to  the 

mains power supply through a fuse dependent 
by the total amount of the line’s  power load

.

3. 

It  is  suggested  to  check  every  month  the 

indication  LED  for  battery  charging,  and  by 
pushing  the  TEST  button  to  check  the 

emergency circuit. The led strip should light as 
long  as  the  TEST  button  is  pressed.

  If  the 

luminaire  doesn’t  work  as  described  above 
contact the installer.

 

4. 

It is suggested to check every 6 months the 

m i n i m u m   a u t o n o n o u s   d u r a t i o n   b y  
disconnecting  the  mains  power  supply

Count 

the time that  the led strip lights and in case of 
less  time  than  the  nominal  autonomy,  the 
battery must be replaced. If the measured time 
i s   c o n s i d e r a b l y   l e s s   t h a n   t h e   n o m i n a l  
autonomy

 

  In  case  of 

contact  the  installer.

battery or led strip replacement, these must be 
replaced  by  parts  of  the  same  type,

  by  the 

manufacturer or 

by a competent person.

5. 

In  case  of  inactive  use  for  a  period  greater 

than  2  months,  disconnect  the  battery  by 
pulling out the battery’s connector.

 

6. 

I s not allowed to discard batteries in to 

t i

common  trash  bins,  they  must  be 
discarded  only 

in  battery  recycling 

points.

 

Do not incinerate.

The  light  source  contained  in  this 
luminaire  shall  only  be  replaced  by  the 

manufacturer,  or  his  agent,  or  a  similar 

qualified person.

NOTE! The light source is non-user 
replaceable.

NON

 

MAINTAINED / MAINTAINED EMERGENCY LUMINAIRES

923378005

_09_008

Page 1 from

 

3

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT
GUARANTEE 

OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES (Ni-Cd)

CHARGING TIME

INDICATIONS 

CONTROLS

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH

ILLUMINATION

 

(230V AC

 

/ emergency) 

ILLUMINATION SOURCE 

1.5 h

3

 h

24 h

Battery charge indication LEDs

TEST button

IP 42

  

12

 white LEDs

EN 60598-1, EN 60598-2-22

, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3

o

5 to 40  C

Up to 95% 

Bayblend FR3010

transparent 

 

polycarbonate

3 years 

(1 

year for the battery

)

240 x 90 x 44 mm

345gr.

220-240VAC/50-60Hz

350gr.

 GR-8/leds

 GR-9/leds

3.6V/0.6Ah

3.6V/1Ah

2.7W/3VA

3W/3.5VA

  40lm / 100lm

  38lm / 100lm

TECHNICAL CHARACTERISTICS

 

 (

for led module spcifications see page 2

)