background image

Page

 

1 from

 6

                         MAINTAINED/NON MAINTAINED ILLUMINATION SIGNS WITH GREEN LEDs

GENERAL

These  new  sign  illumination  luminaires,  use  a  new 
technology,  friendly  to  the  environment  ,  with  high 
illuminated    L.E.D.s.  L.E.D.  technology  has  very  low 
power consumption. The edge illumination sign is used 
as  a  maintained  backup  lighting  with  indications 
symbols. Each package contains arrows stickers which 
are  used  to  quickly  design  the  required  sign  which  is 
suitable for each occasion.
Just  place  the  sign  on  the  figure  which  is  designed  on 
the packages and stick the arrow.
Each  model  combines  modern,  aesthetics,  together   
with functionality. The exit illumination signs are used in 
every  public  area  where  clear  direction  and  good   
appearance  are  important.

NON MAINTAINED OPERATION

By default the illumination sign operates as maintained. 
The  device  has  a  possibility  to  operate  as  non 
maintained.  To  change  the  maintained  to  non 
maintained  operation  follow  the  relative  instructions  on 
page 6. All models must be permanently  connected to 
the  mains  power  supply  as  shown  on  page  2.  The 
legend  is  screened  on  to  a  clear  acrylic  sheet  which 
has the marking on the marking panel with the light that 
comes from the top of the luminaire and diffracts, giving 
light  to  the  marking  panel.  The  luminaire  has  an 
indication  (CHARGE)  for  the  charging  of  the  battery 
and  a  (TEST)  button  to  TEST  the  emergency  circuit 
and  the  LEDs  for  good  operation  only  when  the 
luminaire  is  powered  by  the  mains  power  supply.  The 
unit must be mounted in a clearly visible area and can 
either  be  hung  on  a  ceiling  or  mounted  on  a  wall 

depending  on  the  requirements  of  the  installation. 
The  package  includes  all  the  required  materials  for 
mounting  on  the  wall  or  on  the  ceiling.  The  pages 
2,3 and 4 show us the mounting methods.

WARNING !!

1. Read carefully this instruction manual.
2. Before service interrupt the mains power supply.
3.

 

The  device  must  be  connected  to  the  mains 

power supply through a fuse dependent by the total 
amount of the line’s  power load

.

4. It  is  suggested  to  check  every  month  the 

 

indication  LED  for  battery  charging,  and  by  pushing 
briefly  the  TEST  button  to  check  the  emergency 
circuit.  The  sign  should  light  for  a  few  seconds 
powered by the battery and then, will turn to normal 
operation

.  In  the  opposite  condition  contact  the 

installer.

 

5. 

full 

Every six months, a 

duration check should be 

carried  out 

by  disconnecting  the  mains  power 

supply Count  the  autonomous  duration  of  the 

luminaire  and  in  case  of  no  correspondence  to 
stated  emergency  duration  replace  the  battery The 

replacement of the battery must be done using parts 

 

of  the  same  type,  by  the  manufacturer  or  by  a 
competent person.

6. 

In case of inactive use for a period greater than 2 

months,  disconnect  the  battery  by  pulling  out  the 
battery’s connector.

7

Replaced  batteries  must  not  be  thrown  into 

trash  bins.  They  must  be  returned  to 
special  battery  disposal  points.  Do  not 
incinerate.

9225044

00

_09_027

Thank you for your trust in our product  

Olympia Electronics - European manufacturer

 MLD-34S/g

MLD-44S/g

 MLD-28S/g

220-240V AC/50-60Hz

3h

24h

Overcharging and deep discharging protection

IP 40

class 

II

3.6V/1Ah

22lm / 18lm 

  18lm / 18lm 

ο

5

 

to

 40  C

Up to

 95% 

280x100mm

305x25x155mm

3 years (1 year for the battery)

500gr.

800gr.

1160gr.

340x170mm

350x25x205mm

440x220mm

465x25x275mm

3W / 8VA

3W / 

7

.

5

VA

TECHNICAL CHARACTERISTICS

 

 

(

for LED MODULE Specs. see page

 4

)

Operation  temperature range

Relative humidity
External panel's dimensions
External dimensions (LxWxH)

Typical weight

Guarantee

Mains voltage

Maximum power consumption
Battery (Ni-Cd)

Recharging  time

Battery protection

Minimum emergency duration

Degrees of cover protection
Class of cover protection
Produced in accordance with 

Light source intensity (Mains / Emerg)

Construction materials

ABS/PC,Plexiglass,PVC

EN 60598-1, EN 60598-2-1, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3

Reviews: