ATTENTION!!!
CAUTION : Do not view directly with bare eyes.
OLY-1024/WL
IP42
923102405_09_001
923102405_09_001
4
5
LABELING EXPLANATION:
NOTE:
LED= Light Emitting Diode
X:
Self contained
60:
1 hour duration
F:
Automatic test gear complying with IEC 61347-2-7 denoted EL-T
C:
Including inhibiting mode
B:
Including remote test mode
A:
Including test device
1:
Maintained operation
(*)
180:
3 hours duration
480:
8 hours duration
(*) Maintained operation: The luminaire lights its illumination source, when it is powered by the
mains power supply or not.
Non Maintained operation: The luminaire lights its illumination source, only in mains power supply’s
failure.
OLY-1024/WL
Olympia Electronics S.A.
10-12V DC
1h: 2W
3h: 1.6W
8h: 0.5W
2801205
50 °C max. across the board
Non reversible connection between main pcb and led module
Warranty
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty
is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which
accompanies each product. This warranty ceases to exist if the buyer does not follow the technical
instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods
provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed
to them in writing. Products that have been damaged can be returned to the premises of our company for
repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the
buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the
buyer the transportation cost.
European
manufacturers
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.gr
info@olympia-electronics.gr
Non
maintained
NM
Olympia Electronics - European manufacturer
Thank you for your trust in our products
Maintained
Μ
Warranty
LED Characteristics
MANUFACTURER
MODEL NUMBER
VOLTAGE RANGE
CONNECTIONS
NOMINAL POWER
TEMPERATURE (tc)
OLY-1024/WL
220-240V AC / 50-60Hz
4.6W / 4.8VA
Technical Characteristics
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
3.6V/3 Ah
0.9
BATTERY (Ni-Cd)
INSULATION BETWEEN SUPPLY & CONTROL TERMINALS
MINIMUM POWER FACTOR
WIRE CROSS SECTION
MAX OPEN CIRCUIT VOLTAGE
Irated
Prated
U-OUT
SUPPLY CURRENT
Basic insulation
1h: 2W
3h: 1.6W
8h: 0.5W
1h: 176mA
3h: 146mA
8h: 45mA
22V
22V
19mA
2
2
0.5mm - 2.5mm
BATTERY PROTECTION
4 Power LEDs
1 h, 3 h, 8 h
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
24 hours
LED Charge, Lamp Fault LED, Battery Fault LED
EN 60598-1, EN 60598-2-22, ΕΝ 55015,
ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
IP42
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
o
5 to 40 C
ABS/PC, PC
770gr.
270 x 147 x 48 mm
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION (L x W x H)
WEIGHT
GUARANTEE
Up to 95%
3 years (1 year for the battery)
INDICATIONS
Deep discharge and overcharge protection / the control gear will recharge the battery normally after the test of 22.3
1h: 500-900mA
3h: 410-695mA
8h: 130-215mA
190-210mA
100mA
MIN MAX. DISCHARGE VOLTAGE
MIN MAX. DISCHARGE CURRENT
MIN MAX. CHARGE CURRENT
TRICKLE CHARGE VOLTAGE/CURRENT
MAX CHARGE VOLTAGE
3-4.5V
6V
LIGHT SOURCE LUMINOUS FLUX (MAINS / EMERGENCY)
300lm / 380lm (1 h), 320lm (3 h), 100lm (8 h)
CONTROL GEAR MAX. TEMPERATURE:tc
o
50 C at R18/R19
CONTROL GEAR WITH AUTOMATIC
TEST FUNCTION
Manual Test
380/320/100lm
Light output
1h/3h/8h
Duration
NOTE!
! The light source is non-user replaceable.
The light source contained in this luminaire shall only be replaced by the manufacturer, or
his agent, or a similar qualified person.
2. Follow step 2 of the installation instructions and remove the reflector.
3. Remove the old battery and place a new one of the same type and characteristics.
It can be done only by a competent person and after the mains interruption
.
1. Follow step 1 of the installation instructions and remove the diffusor.
4. Replace the removed parts (previous steps 1 and 2).
Battery Replacement
Lens Removal
2
2
1
1
SELFTESTING
MAINTAINED/NON MAINTAINED EMERGENCY LUMINAIRE
WITH WIRELESS COMMUNICATION
Wireless
X 1
6 0
A
F
B C
Tx POWER
Tx/Rx FREQUENCY RANGE
11dBm
868-870MHz