background image

GR-409/12L

220-240V AC/50-60Hz

IP 42

3

.

6

V/1Ah

  85lm 

EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3

51

0gr.

272 

x 121 x 50 mm

923409007_09_0

0

4

3

.

6

V/600mAh 

3W /3.5VA

2.5W /3VA

500gr.

 

GR-408/12L

Thank  you  for  purchasing  this  product  of 
Olympia Electronics. A European manufacturer.

GENERAL

o

These  luminaires  are  used  indoors 

(

ta  40 C

)

 

where emergency light is needed.
Each luminaire must be permanently connected 
to mains power supply

.

In normal operation the battery is charging and 
the 2 yellow LED’s light in the screen.
In  case  of  a  mains  power  supply failure  the  
luminaire  will  light the led strip  automatically in 
emergency  mode.    When  the    mains    power   
supply    is    restored  the  device  turns  to  normal 
operation.

MAINTAINED / NON-MAINTAINED 
OPERATION

There  is  an  option  to  select  the  maintained  or 
non-maintained operation by placing the jumper 
to  the  appropriate  place  according  to  step  8 
(page 4)

.

INSTALLATION

To  install  the  luminaire  follow  the  installation 
instructions 

ο

n page 4.

ΑΤΤΕΝΤΙΟΝ

!!!

1.  Operations  for  installation,  maintainance  or 
testing  must  be  done  by  authorized  personel 
only

.

2. 

The  device  must  be  connected  to  the  mains 

power supply thru a fuse dependent by the total 
amount of the line’s  power load

.

3. 

It  is  sugested  to  check  every  month  the 

indication LED for battery charging, and by 
p u s h i n g   t h e   T E S T   b u t t o n   t o   c h e c k   t h e  
emergency  circuit.  The  led  strip  should:  a)  light 
with bigger intensity as long as the TEST button 
is pressed (maintained operation),
b)  light  as  long  as  the  TEST  button  is  pressed 
(non-maintained  operation).

4. 

It  is  sugested  to  check  every  6  months  the 

minimum autononous duration by disconnecting
the mains power supply

Count the time that  the 

led  strip  lights  and  in  case  of  less  time  than  the 
minimum  autonomous  duration  the  battery  must 
b e   r e p l a c e d .   I f   t h e   m e a s u r e d   t i m e   i s  
considerably less than the minimum autonomous 
duration 

  In  case  of  battery 

or led strip replacement, these must be replaced 
by  parts  of  the  same  type,  by  the  manufacturer 
or by a competent person.

t  i

in  battery  recycling 

points.

 

Do not incinerate.

  If  the  luminaire 

doesn’t  work  as  described  above  contact  the 
installer.

 

contact  the  installer.

5. 

In  case  of  inactive  use  for  a  period  greater 

than 2 months, disconnect the battery by pulling 
out the battery’s connector.

 

6. 

I

s  not  allowed  to  discard  batteries  in  to 

common  trash  bins,  they  must  be 
discarded  only 

TECHNICAL CHARACTERISTICS

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT
GUARANTEE 

OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES

 (

Ni-Cd

)

CHARGING TIME

INDICATIONS 

CONTROLS

BATTERY PROTECTION

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

EMERGENCY ILLUMINATION

ILLUMINATION SOURCE 

24h

From overcharge and full discharge

  12 white LED’s 

Bayblend FR3010

transparent 

 

polycarbonate

180min

0 to 40  C

o

Up to 95% 

3 years 

(1 

year for the battery

)

90min

Page

 1

 from

 4

Battery charging LED

TEST button

‘’

COMFORT LIGHT‘’ SERIES FOR NON-MAINTAINED

/ΜΑΙΝΤΑΙΝΕ

EMERGENCY LUMINAIRES

High Quality European based Manufacturers

Reviews: