MOTORIZED 248 nm UV

MICROSCOPE UNIT

INSTRUCTIONS

U-UVF248A

A X 7 6 8 0

This instruction manual is for the Olympus Motorized 248 nm UV Microscope Unit Model U-UVF248A.
To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use of
this unit, we recommended that you study this manual thoroughly before operating the microscope
system. To understand the comprehensive operating procedures, it is also recommended to read
the instruction manual for the manual type U-UVF248 unit (packaged together with the U-UVF248IM).
Retain this instruction manual in an easily accessible place near the work desk for future reference.

Summary of Contents for U-UVF248A

Page 1: ...amiliarize yourself fully with the use of this unit we recommended that you study this manual thoroughly before operating the microscope system To understand the comprehensive operating procedures it is also recommended to read the instruction manual for the manual type U UVF248 unit packaged together with the U UVF248IM Retain this instruction manual in an easily accessible place near the work de...

Page 2: ...uired to correct the interference at his own expense FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment For Korea only A급 기기 업무용 방송통신기자재 이 기기는 업무용 A급 전자파적합기기로서 판 매자 또는 사용자는 이 점을 주의하시기 바라 며 가정외의 지역에서 사용하는 것을 목적으로 합니다 This device complies with the requirements of directive 2004 108 EC concerning...

Page 3: ...OLS 3 PREPARATION 4 SUMMARY OF VISIBLE UV LIGHT OBSERVATION PROCEDURE 5 SPECIFICATIONS 6 TROUBLESHOOTING GUIDE FOR UV OBSERVATION 7 ASSEMBLY 4 5 6 7 8 9 10 11 12 U UVF248A 1 Centering the Mercury Xenon Burner 6 2 Adjusting the Illumination Center 7 8 PREVENTIVE INSPECTION SHEET FOR ILLUMINATION DEVICES 13 ...

Page 4: ...tter monitors the drive status of the MX61A to prevent accidental irradiation of UV light However care is still required against UV leak from the revolving nosepiece and specimen surface 2 To prevent unexpected irradiation of UV rays be sure to close the idle objective positions of the revolving nosepiece by attaching the caps provided with the revolving nosepiece 3 Leakage of UV light can be prev...

Page 5: ... the main switch of the power supply is set to OFF 8 Be sure to ground the power supply to ensure safety If it is not grounded earthed Olympus can no longer warrant the electrical safety performance of the equipment 9 Before opening the lamp housing for replacing the burner etc be sure to set the main switch of the power supply to OFF disconnect the lamp housing output connector on the power suppl...

Page 6: ...on xenon burner U LH80HGXE Power supply High voltage caution Caution indications Caution indications are affixed at parts where special precaution is required when handling and using the microscope Always heed the cautions Caution indication positions ...

Page 7: ...or for UV observation Recommended TV camera Sony XCD SX910UV Image measuring software analySIS FIVE Active AF unit UV Objective MApo100X for 248 nm UV Rays Objectives for visible light UIS2 UIS series Microscope frame MX61A UV248 Observation Tube U UVF248IM UV Light Guide U UVF2FB U UVF5FB Lamp Housing for Mercury Xenon Burner U LH80HGXE Mercury Xenon Burner UXM80E UV248 Light Source Box U UVF248L...

Page 8: ...LBM Centering scope Page 6 UV light guide mount Camera cable connector Caution label Page 1 Lamp housing mount Page 12 BNC connector Motorized shutter light intensity adjustment cable connector Motorized shutter light intensity adjustment cable ...

Page 9: ...ation mode and perform the final adjustment to make the image observed on the UV observation monitor brightest 5 Attach the cap in the original position After long hours of use the electrodes will be consumed and the centering position be deviated The centering should therefore be adjusted periodically Be sure to re adjust centering after replacing the burner Fig 2 The motorized control of the MX6...

Page 10: ... image is not displayed or abnormally dark the illumination center is deviated In this case the light guide mount should be adjusted 7 Using a Phillips screwdriver loosen slightly the three clamping screws of the UV light guide mount 8 Insert the provided Allen screwdriver alternatively into the two adjustment screws and turn the screws until the brightest observation image is obtained 9 After com...

Page 11: ... a visible light objective with low magnification in the light path 3 Place the specimen and adjust the focus and brightness 4 Engage a visible light objective with high magnification in the light path and adjust the focus and brightness Use autofocusing when the AF unit is used 1 Select the DUV observation mode using the menu of the MX2 BSW The MApo100X objective for UV light is automatically eng...

Page 12: ...amp housing U LH80HGXE Mercury xenon burner UXM80E Life Approx 1000 hours Power supply U HX T Optical wavelength 248 4 nm Brightness adjustment 0 to 100 Adjustment with pulse motor drive Shutter Shutter opening closing with pulse motor drive Dimensions weight 170 W x 170 H x 240 D mm approx 3 6 kg ...

Page 13: ...e stabilizes The shutter of the light source box is closed Set the shutter to Open using the menu of the MX2 BSW The observation mode other than DUV is set Select DUV in the menu of the MX2 BSW No UV light objective is mounted on the revolving nosepiece Mount the MApo100X objective for 248 nm UV light The mercury xenon burner is not cen tered correctly Adjust the centering correctly The illuminati...

Page 14: ...t the positive pole of the burner into the positive side socket hole and tighten the other screw Be sure to use the UXM80E burner mfd by USHIO that is available through Olympus Be careful not to soil the burner with fingerprints or dust If it becomes dirty wipe clean the burner surface with a piece of gauze moistened with absolute alcohol If contaminants are left on the burner surface dark spots m...

Page 15: ...on the end surfaces 2 Insert the input connector into the UV light guide mount on the UV248 light source box by aligning the positioning marks and tighten the clamping ring 3 Loosen the clamping knob and insert the output connector ƒ all the way Clamp the connection so that the clamping knob is aligned with the positioning reference plane Fig 6 1 Loosen the two lamp housing clamping screws of the ...

Page 16: ...hed on the right or left side Except discharge burners 1 9 Illumination device housing has become deformed cracked or tarnished in any way 10 Lamp cables or wiring parts have become deformed cracked or tarnished in any way We recommend performing Preventive Inspections periodically every time you replace lamps and at least once every 6 months The table below identifies the check items to be observ...

Page 17: ...MEMO ...

Page 18: ...MEMO ...

Page 19: ......

Page 20: ...Manufactured by Distributed by AX7680 03 Printed in Japan on December 25 2012 M 000 03 ...