User’s Guide

DATALOGGER 4 INPUT 

THERMOMETER

HH1384

INSTRUCTION MANUAL 

M A X   M IN  

ALAR M

-

IN TV

m :s

d-h

FU LL

N O .

T 4

T 3

T 2

T 1

 

 

 

 

Office: Jl. Radin Inten II No. 62 Duren Sawit, Jakarta 13440 - Indonesia
Workshop: Jl. Pahlawan Revolusi No. 22B, Jakarta 13430 - Indonesia
Phone: 021-8690 6777 (Hunting)

Fax: 021-8690 6777

Mobile: +62 816 1740 8925

Fax: 021-8690 6771

Summary of Contents for HH1384

Page 1: ...ON MANUAL MAX MIN ALARM INTV m s d h FULL NO T 4 T 3 T 2 T 1 Office Jl RadinIntenIINo 62DurenSawit Jakarta13440 Indonesia Workshop Jl PahlawanRevolusiNo 22B Jakarta13430 Indonesia Phone 021 86906777 Hunting Fax 021 86906777 Mobile 6281617408925 Fax 021 86906771 ...

Page 2: ...ion provided by the meter may be impaired Environment conditions Altitude up to 2000 meters Relatively humidity 80 max Operation Ambient 0 50 C 32 F 122 F Features Isolated Input Protection of 350Vp p between any two inputs Highly accurate thermometer with thermocouple K J E T R S N L U B C types 4 input function T1 T2 T3 T4 temperature display Programmable Hi Lo alarm for 4 inputs Display of MAX ...

Page 3: ...05 1 8 F 0 2 1 F T 200 150 150 100 100 400 3 0 C 0 15 2 5 C 0 1 1 0 C 328 238 238 148 148 752 5 4 F 0 15 4 5 F 0 1 1 8 F R S 0 100 100 300 300 999 9 1000 1600 5 0 C 3 0 C 0 05 2 0 C 0 25 2 0 C 32 212 212 572 572 999 9 1000 2912 9 0 F 5 4 F 0 05 3 6 F 0 25 3 6 F N 0 999 9 1000 1300 0 1 1 0 C 0 2 1 0 C 32 999 9 1000 2372 0 1 1 8 F 0 2 1 8 F L 200 900 0 1 1 0 C 328 999 9 1000 1652 0 1 1 8 F 0 2 1 F U...

Page 4: ...ifications Power Supply 6 pcs size AA battery or DC 9V AC adaptor Battery Life approx 55 hours Alkaline battery Auto Power Off 5 15 or 30 minutes If no key is pressed Low Battery Indicator The is displayed when the battery voltage drops below the operating voltage Measurement Rate One time per 2 seconds Weight 405g 14 3oz batteries included Dimension 18 7 L 7 3 W 5 3 T cm 7 3 L 2 9 W 2 1 T Operati...

Page 5: ...ONTROLS 3 1 Description of Parts Control keys 8 MAX MIN ALARM INTV m s d h FULL NO T 4 T 3 T 2 T 1 5 13 10 11 7 4 3 6 15 14 12 9 2 1 1 LCD Display 2 Key Power on off control key 3 Keys Setting keys 4 HOLD Key 4 ...

Page 6: ...F key to switch the units between Celsius C and Fahrenheit F 7 TYPE Key Press TYPE key to enter the thermocouple type select mode press this key again to exit this mode 8 TIME Key Press TIME key to circulate display data and time 9 ALARM Key Press ALARM key to enable or disable Alarm function 10 MEM Key Manual data memory control key 11 SET Key Press SET key to start or exit setup 12 READ Key Manu...

Page 7: ...Input temperature exceeds the high limit value indication ALARM Input temperature is below the low limit value indication T1 T2 T3 T4 Thermocouple T1 T2 T3 T4 input temperature measurement display Battery capacity indication Replace batteries indication NO Last manual data memory address number indication 01 99 M Manual data memory indication M displays one time store one sets data into the memory...

Page 8: ...onnect thermocouples from the meter before opening the case Replace the batteries as soon as the battery indicator appears The possibility of false reading can lead to personal injury Do not use the meter if it operates abnormally Protection may be impaired Do not operate the meter around explosive gas vapor or dust Do not use the meter with any part of the case or cover removed 4 1 Setting the me...

Page 9: ...often the meter stores logged readings in memory a Press key to turn on the meter b Press SET key to enter the setting mode then press or key until the display shows Set Intr c Press key to enter the interval time setting mode and the three flicking numbers of second d Press or key to set the desired second of interval time 1 to 255 seconds e Press key to store the auto datalogging interval time f...

Page 10: ... shows SEt SLEEP c Press key to enter the auto power off time setting mode the SLEEP symbol is displayed d Press or key to choose the desired auto power off time The choices are 5 15 and 30 minutes e Press key to store the choice f Press SET key to exit this mode 5 Alarm High Low Limit setting a Press key to turn on the meter b Press SET key to enter the setting mode then press or key until the di...

Page 11: ...ow temperature value the symbol will flicking display the beep will sound one time per 4 seconds l Press ALARM key again to exit the alarm function 4 2 Setting the Thermocouple Type 1 Press key to turn on the meter 2 Press TYPE key to enter the thermocouple type choices The currently selected thermocouple type blinks 3 Press or key to select the desired T1 T2 T3 or T4 4 Press or key until the ther...

Page 12: ... 3 Press HOLD key to paused recording the H symbol is displayed press HOLD key again will resume recording 4 Press MAX MIN key for 2 seconds to exit this mode 4 5 Manual Data Memory and Read Function Operation 1 Clear the manual memorized data a Press key to turn off the meter b Press and hold down MEM key then press key again to turn on the meter the CLr YES no M symbol is displayed c Press or ke...

Page 13: ...displayed c Press key to enter the clear auto datalogged data mode the CLr YES no AM symbol is displayed d Press or key to select YES symbol is displayed flickering e Press key to clear the auto datalogged data and exit this mode 2 Store Auto datalogging data to memory a Press MEM key for 3 seconds to start auto datalogging the A M symbol is displayed the A M symbol according to the interval time ...

Page 14: ...y user setting to save power consumption 1 Disable auto power off procedure a Press key to turn off the meter b Press and hold down HOLD key then press key to turn on the meter the auto power off function will be disabled and the auto power off symbol will disappear 2 Auto power off mode is enabled each time you turn on the meter and is automatically disabled bt the follow modes a MAX MIN record m...

Page 15: ... Take care not to reverse the and polarity when inserting the batteries Always replace all six batteries together Do not mix old and new batteries or batteries of different type Remove the batteries from the meter if the meter is not to be used for a month or longer 6 USB INTERFACE SOFTWARE INSTALLATION AND OPERATION For the detailed instruction please refer to the content of attached CD ROM which...