background image

  e-mail: info@omega.com 

For latest product manuals: 

www.omegamanual.info

Shop online at 

omega.com

®

User’s Guide

HHM9007R

Digital Multimeter

MADE IN TAIWAN

µ

µ

Digital

Multimeter

HHM9007R

Summary of Contents for HHM9007R

Page 1: ...e mail info omega com For latest product manuals www omegamanual info Shop online at omega com User sGuide HHM9007R Digital Multimeter MADE IN TAIWAN Digital Multimeter HHM9007R...

Page 2: ...prior written consent of OMEGA ENGINEERING INC RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO O...

Page 3: ...a safety situation a rugged case that is shock resistant and fire retardant and electronic overload protection for all functions and ranges In addition a carrying case optional accessory is available...

Page 4: ...al Keep your body isolated from ground by using dry clothing rubber shoes rubber mats or any approved insulating material 5 To avoid electric shock use CAUTION when working with voltages above DC60V o...

Page 5: ...0V CAT IV 600V Class II Pollution degree 2 Indoor use CAT III Is for measurements performed in the building installation CAT IV Is for measurements performed at the source of the low voltage installat...

Page 6: ...13 12 5 4 3 cal 2s ns mV V mV MAX 400mA TRUE RMS AC DC Digital Multimeter HHM9007R 30V MAX AUTO POWER OFF CAT III V Hz SHIFT C F K Type CATIV 600V 0 10 20 50 30 40 60 HOLD MIN MAX RANGE REL COM mA A...

Page 7: ...ent measurement Connection is made to it using the red test lead 5 Temperature Input Jacks Remove leads and slide the temp switch to the right to close lead jacks 6 Function Range selector rotary swit...

Page 8: ...utton for more than 2 seconds to exit 3 Response time more than 1ms 14 REL Button 1 Press REL button to enter the Relative mode The appears to indicate that the relative mode is activated and non zero...

Page 9: ...bnormal conditions exist do not attempt to make any measurements VOLTAGE MEASUREMENTS 1 Turn off power to the device under test and discharge all capacitors 2 Plug the black test lead into the COM inp...

Page 10: ...A mA 20A AC DC TRUE RMS function AC DC TRUE RMS AC RMS component 2 DC component 2 RESISTANCE CONDUCTANCE MEASUREMENTS 1 Set the Function Range switch to the ns position Use the SHIFT button to select...

Page 11: ...to the position 2 Connect the red test lead to the jack and the black test lead to the COM jack 3 Touch the probes to the capacitor Observe polarity when measuring polarized capacitors 4 Read the cap...

Page 12: ...he duty cycle test 2 Connect the red test lead to the V jack and the black test lead to the COM jack 3 Connect the test leads to the point of measurement and read the duty cycle from the display RS232...

Page 13: ...with a continuous beep sound and the meter shuts down in 5 seconds and no further measurement is allowed Measurement Rate 2 0 sec nominal 20 sec Analog bar graph Operating Environment 0 C to 50 C at 7...

Page 14: ...cy 45 60Hz HFR1 lnput lmpedance 600mV 0 01mV 2 0 red 20d 45 60Hz 10M 6V 0 1mV 11M 60V 1mV 10M 600V 10mV 10M 750V 100mV 10M AC DC Volts True RMS Range Reso lution Accuracy 45 2kHz lnput lmpedance 600mV...

Page 15: ...01 A 2 0 red 30d 6000 A 0 1 A 60mA 1 A 400mA 10 A 20A 1mA 3 0 red 30d Voltage burden 500mV on 600 A 60mA ranges 2V on 6000 A 400mA 20A ranges Input protection 0 5A 1000V fast blow ceramic fuse 6 3x32m...

Page 16: ...100ms 3 0Vdc Overload protection 600V DC or 600V AC RMS Diode Test Range Resolu tion Accuracy Test Current Open Circuit 2V 1mV 2 0 red 10d 0 5mA 3 0Vdc typical Audible indication Less than 0 05V Over...

Page 17: ...ol ution Accuracy Sensor type 0 C 400 C 0 1 C 1 0 red 1 C K type Thermocou ple 50 C 0 C 400 C 1300 C 2 0 red 3 C 32 F 750 F 0 1 F 1 0 red 2 F 58 F 32 F 750 F 2372 F 2 0 red 6 F Overload protection 30V...

Page 18: ...Width 100ns Duty cycle limits 30 and 70 Overload protection 600V DC or 600V AC RMS MAINTENANCE Maintenance consists of periodic cleaning and battery replacement The exterior of the instrument can be...

Page 19: ...ch to OFF and remove the test leads from the input terminals 2 The bottom case is secured to the top case by four screws Using a Phillips head screwdriver remove the screw from the bottom case and rem...

Page 20: ...ver OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA eit...

Page 21: ...Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial pH Conductivity Equipment DATA ACQUISITION M U Data Acquisition Engineering Software M U Communications Based Acquisition...

Reviews: