Operating manual

 

 

 
 

image of the product

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Omegon® BinoView Microscope 1000x 

English Version 03.2023 Rev. A Item No. 33128 

 

 

Summary of Contents for BinoView 1000x

Page 1: ...rivate use is expressly prohibited in any form Subject to changes and errors All texts images and marks are the property of NIMAX GmbH 33128_DE_Bedienungsanleitung_REV_A 1 5 Operating manual image of the product Omegon BinoView Microscope 1000x English Version 03 2023 Rev A Item No 33128 ...

Page 2: ...transmitted light microscope Dimmable lighting LED Achromatic lenses 4x 10x 40x 100x Specimen protection for the 40x and 100x lens Work distances of the lenses o 4x 37 50 mm NA 0 10 o 10x 7 63 mm NA 0 25 o 40x 0 63 mm NA 0 65 o 100x 0 20 mm NA 1 25 Eyepieces WF 10x Magnifications 40x 100x 400x 1000x Oil Abbe condenser NA 1 25 with iris diaphragm Coaxial cross table Fine adjustment in X Y axis Coar...

Page 3: ...must not be damaged in any way to ensure safe use In the event of a defect contact the support department at NIMAX GmbH 2 Initial operation 2 1 Switch on the device and adjust the brightness on the dimmer wheel 16 to a pleasant but required luminous intensity 2 2 Adjust the pinhole on the condenser to change the light irradiation Adjust the design related aperture pinhole of the lenses to achieve ...

Page 4: ... only have to turn the fine adjustment to finally achieve image sharpness again 2 7 By turning the coaxial stage mechanism 12 the specimen can be manually moved precisely and carefully along the Y and Z axes through the eyepiece field of view 2 8 The lateral fine adjustment which moves the condenser from below towards or away from the specimen can be used to control the degree of illumination and ...

Page 5: ...ittle isopropanol alcohol pharmacy Please do not clean the lens surface too often with isopropanol Frequent use may cause scratches and damage to the coating resulting in poor light transmission and poor image quality 3 3 Care The microscope should be stored in a shady dry and clean place It must not come into contact with acids bases or vapours Do not expose the device to direct sunlight The work...