User Warranty Registration
Please complete both sides and mail or fax this form to the address indicated on
the other side.
FlexPoint T
ype:
S
TR Fiber
T
ype _______ Connector _________
Model:
________________________________________________
Serial Number: ______________
Purchase
Date:
______________
Purchased From: _________________________________________
Address:
______________________________________________
City: ___________________ S
tate:
_______
Zip Code:
________
Country:
_______________________________________________
Comments and
Suggestions:
_______________________________
______________________________________________________
______________________________________________________
Please complete both sides of this form
FlexPoint
TM
TR User Instructions
Description:
The FlexPoint
TM
TR converts between 4/16 Mbps Token
Ring twisted pair (RJ45 UTP) and fiber cabling. The
following models are described here:
Model UTP
Fiber
4360
Category 3 / 5
Multi-mode, ST, 850 nm
4361
Category 3 / 5
Singlemode, ST, 1310 nm
Power Adapter Notice:
1.When using in a stand-alone configuration, this product
is intended to be used and must be used only with a
Listed Direct Plug-In Power Unit marked “Class 2” and
rated at 9Vdc, 1 Amp.
2.This product should always be used only with Omnitron
supplied Power Unit model number 9113-PS.
WARNING!
Before inserting the Power Adapter, verify that
the power on the unit is appropriate for your AC
line voltage source.
Mounting:
The FlexPoint TR can be wall mounted individually or
rack-mounted using a 5-position shelf, FlexRack 5, or a
power-redundant FlexPoint Powered Chassis.
Installation:
For all connections, attach the fiber between the two
FlexPoint TR units first, the “Fiber Ready” LED on both
units should turn ON.
Select the appropriate “Straight/Crossed” selection for
the type of device connecting to on the UTP side.
1. Workstation (WS) to a hub: Attach the FlexPoint’s
UTP to the hub, “UTP Rdy” should go ON. Attach the
FlexPoint’s UTP to the WS. Reboot the WS, the UTP
and Insert LEDs should turn ON.
2. Ring-Out (RO) to Ring-In (RI): Attach the RI and RO
cables to the hubs. Make sure that at least one WS is
operational on the ring. The “UTP Rdy” on the RO side
FlexPoint TR should turn ON. If using active MAUs,
they might have to be set to 8228 mode.
3. Hub (MAU) to a Switch: Attach to the hub’s lobe, the
“UTP Rdy” LED should turn ON. Attach to the switch’s
port, the “UTP Rdy” and Insert LEDs should turn ON. It
might be required to set the switch to “Cross-Over.”
Technical Support:
For help with this product, contact our Tech. Support:
Phone:
(949) 250-6510
Fax:
(949) 250-6514
Address:
Omnitron Systems Technology, Inc.
140 Technology Drive, #500
Irvine, CA 92618 USA
Email:
support@omnitron-systems.com
URL:
http://www.omnitron-systems.com
Switch Settings:
“RJ45 Cross-Over” Switch:
When connecting the
UTP to a Ring-Out or a Lobe set switch to “Straight-
Through” (factory setting). When connecting to a Ring-
In or a workstation, set it to “Cross-Over.”
“Auto Select/Cable Test” Switch:
When in “Auto
Select” (factory setting), the FlexPoint TR adapts its
operation to the type of equipment it is connected to.
When in “Cable Test,” the FlexPoint supports a fiber or
copper media test.
LED Indicators:
LED
Color Description
Power
Yellow Power applied
Red
Error detected
Inst
Green
Inserted successfully into a
lobe or Ring-In
Yellow Media (Cable) test is enabled
Fiber Ready
Green
Fiber OK
UTP Ready
Green
UTP OK
Cable / Media Test:
When in “Cable Test,” the FlexPoint TR provides a
cabling media test. For fiber test, provide a connection
between the Tx and Rx fiber ports, a good fiber turns
the “Fiber Ready” LED ON. For UTP test, connect a
RJ45 cable to a port in a hub; a good cable turns the
“UTP Ready” LED ON.
User Warranty Registration
Please complete both sides and mail or fax this registration form to:
Omnitron Systems T
e
chnology
, Inc.
140 T
echnology Drive, #500
Irvine, CA 92618, USA
Fax: (949) 250-6514
Name:___________________________________________________
Company:
______________________________________________
Address:
______________________________________________
______________________________________________
City: ___________________ S
tate:
_______ Zip
Code:
___
_____
Country:
_______________________________________________
Phone: ____________________
Fax:
_______________________
Email:
_________________________________________________
Please complete both sides of this form
WARNING!
Before inserting the Power Adapter, verify
that the power on the unit is appropriate
for your AC line voltage source.
Warning
The operating description in this Instruction Manual is
for use by qualified personnel only. To avoid electrical
shock, do not perform any servicing of this unit other
than that contained in the operating instructions, unless
you are qualified and certified to do so by Omnitron
Systems Technology, Inc.
Caution
All user-required operations can be performed without
opening the unit. Never attempt to open or remove the
cover or tamper with the unit.
Warranty
This product is warranted to the original purchaser
against defects in material and workmanship for a period
of TWO YEARS from the date of shipment. A LIFETIME
warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90
days from the date of shipment. TO REGISTER,
COMPLETE AND MAIL OR FAX THE REGISTRATION
PORTION OF THIS INSTRUCTION MANUAL TO THE
INDICATED ADDRESS. During the warranty period,
Omnitron will, at its option, repair or replace a product
which is proven to be defective.
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense.
Omnitron will pay the shipping charge to return the
product to Buyer’s designated US address using
Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects
resulting from improper or inadequate use and/or
maintenance of the equipment by Buyer, Buyer-supplied
equipment, Buyer-supplied interfacing, unauthorized
modifications or tampering with equipment (including
removal of equipment cover by personnel not specifically
authorized and certified by Omnitron), or misuse, or
operating outside the environmental specification of the
product (including but not limited to voltage, ambient
temperature, radiation, unusual dust, etc.), or improper
site preparation or maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
Form: 040-04360-001B 11/07
Notes:
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
_____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________