background image

Specifications

Item

Applicable Controllers
Lighting color (peak wavelength)
Light source
LED Safety
Electricity

Insulation Resistance
Ambient Temperature
Ambient Humidity
Degree of Protection
Vibration Resistance(destructive)
Shock Resistance (destructive)
Materials
Weight
Accessories

Model

White
Red
Blue

FLV-DB3729W
FLV-DB3729R
FLV-DB3729B
FLV-TCC4□/-TCC1□/-TCC3HB□、FLV-ATC□1024-□  
W:White、R:Red(Typ.625nm)、B:Blue(Typ.460nm)
LED
Risk Group1 (IEC62471)
0.9W
0.9W
0.9W
20 MΩ (250VDC)
Operating: 0 to +50℃, Storage: −15 to +60℃ (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
IP20(IEC60529)
10 to 150 Hz, (0.7mm double amplitude) 80 min. each in X, Y, and Z directions
150 m/s

2

 3 times each in 6 directions(up/down, left/right, forward/backward)

Case:Aluminum, PMMA 
Approx.50g
Instruction sheet (this sheet)

FLV-DB10181W
FLV-DB10181R
FLV-DB10181B

8.1W
4.7W
8.1W

Approx.160g

FLV-DB130130W
FLV-DB130130R
FLV-DB130130B

13.0W
11.5W
13.0W

Approx.270g

FLV-DB212152W
FLV-DB212152R
FLV-DB212152B

29.4W
20.2W
29.4W

Approx.510g

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet 

primarily describes precautions required in installing and 

operating the product.

Before operating the product, read the sheet thoroughly 

to acquire sufficient knowledge of the product. For your 

convenience, keep the sheet at your disposal.

Model

 

FLV-DB

Please observe the following precautions for safe use of the products.

1. Installation Environment

• Do not use the product in environments where it can be exposed to 

inflammable/explosive gas.

• To secure the safety of operation and maintenance, do not install the product 

close to high-voltage devices and  power devices.

• Tighten the screws with the specified torque in this document.

2. Power Supply and Wiring

• For details on power supply and wiring, refer to PRECAUTIONS FOR SAFE 

USE on the INSTRUCTION SHEET of the dedicated controller (FLV-TCC4

   

/-TCC1

/-TCC3HB

, FLV-ATC

1024-

).

• When connecting or disconnecting the lighting connector, be sure to turn off 

the power of the unit.  Not doing so may result in malfunction.

• The temperature may reach 70°C while power is being supplied under 

thermally neutral environment. Do not touch the product directly. Be sure to 

wear heat-resistant gloves.

• High-Voltage lines and power lines must be wired separately from this product. 

Wiring them together or placing them in the same duct may cause induction, 

resulting in malfunction or damage.

• Take sufficient safety measures such as fail-safe circuit to use the product.

3. Others

• Do not use in safety circuits for atomic energy or that are critical for  human life.

• Do not attempt to disassemble, deform by pressure, incinerate, repair, or 

modify this product.

• When disposing of the product, treat as industrial waste.

• Be sure to connect a dedicated lighting controller (FLV-TCC4

/-TCC1

/-TCC3HB

□,

FLV-ATC

1024-

).Use of other devices may result in fire, 

explosion, malfunction or failure.

• If you notice an abnormal condition such as a strange odor, extreme heating of 

the unit, or smoke, immediately stop using the product, turn off the power, and 

consult your dealer.

• Do not drop or impose excessive vibration or shock on the product. 

  It may cause breakdown of the product.

• Ensure that all components which have locking mechanisms are locked before 

using the product.

• Make sure not to drop the product when unpacking or moving it.

4. Regulations and standards

  This lighting complied with the EN standard (EN61326) with a EMC directive 

(No.2004/108/EC).

© OMRON Corporation  2013  All Rights Reserved.

PRECAUTIONS ON SAFETY

PRECAUTIONS FOR SAFE USE

Observe the following to prevent failure, malfunctioning, and adverse effects 

on performance and the device.

1. Installation site

Do not install in the following locations:

• Locations where the ambient temperature exceeds the rated temperature range.

• Locations subject to sudden temperature changes (where condensation will form).

• Locations where the relative humidity is below or above 35 to 85% RH.

• Locations where there are corrosive or flammable gases.

• Locations where there is dust, salt, or iron powder.

• Locations where the device will be subject to direct vibration or shock.

• Locations where there is strong scattered light (laser light, arc welding light, 

ultraviolet light, etc.)

• Locations exposed to direct sunlight or next to a heater.

• Locations where there is splashing or spraying of water, oil, or chemicals.

• Locations where there is a strong electrical or magnetic field.

2. Maintenance

• Do not install the product close to high-voltage devices and/or power devices 

in order to secure the safety of operations and maintenance.

• When this product and a cable are attached or removed, be sure to turn OFF 

the power of the Controller first before operation.

• Never use paint thinner, benzen, acetone, or kerosene to clean the product.Wipe 

the contamination with a soft cloth included a small amount of alcohol.

3. Power and cable connections

• When using a commercially available switching regulator, make sure that the 

Frame ground terminal is grounded.

• If there are surges on your power line, connect a surge absorber as 

appropriate for your conditions of use.

• Before turning on the power after the wiring is completed, verify that the 

power is correct, that there are no incorrect connections such as a shorted 

load circuit, and that the load current is suitable. Incorrect wiring may cause 

damage and failures.

• Use the product with the specified voltage. Applying a voltage or AC voltage 

that exceed the rating may result in burning or explosion of circuit components.

• For cable extension between the lighting and lighting controller, use an 

optional extension cable (FLV-XC

/-XC

R) or branch cable (FLV-XC

S2). Only one extension cable and branch cable can be used.

 • The bending radius at cable wiring must be at least 20 mm.

4.Warming Up

  After turning on the power supply, allow the controller to stand for at least 30 

minutes before use. As the circuits are unstable immediately after power on, 

brightness may gradually change.

5. Lighting electricity

  Lighting electricity for lighting equipment to be connected to the Lighting 

Controller is limited. Be sure to check the lighting electricity written on the 

plate of the product, label of the packaging box or this manual to connect a 

lighting within the specified value.

6. Static Electricity

  LEDs are easily damaged by static electricity. A grounded wrist strap should 

thus be used when installing or conducting maintenance on the Diffusion Board. 

PRECAUTIONS FOR CORRECT USE

● 

Meanings of Signal Words

● 

Alert Statements in This Sheet

This product is not designed or rated for ensuring safety 

of persons either directly or indirectly. Do not use it for 

such purposes.
Do not disassemble the product. Doing so may cause 

electric shock due to the high voltage portion. Burn also 

may result due to high temperature. Do not attempt to 

disassemble, deform by pressure, incinerate, repair, or 

modify this product.

Indicates a potentially hazardous situation which, if 

not avoided, will result in minor or moderate injury, 

or may result in serious injury or death. Additionally, 

there may be significant property damage.

WARNING

Indicates a potentially hazardous situation which, if 

not avoided, may result in minor or moderate injury 

or in property damage.

CAUTION

WARNING

Do not use it exceeding the rated voltage. 

There is a possibility of failure and fire.
Do not connect amplifier units to AC power supply. 

Risk of explosion.

Looking into the LED light continuously may cause visual 

impairment. Do not look directly into the LED light.

CAUTION

Direct BackLighting

The following notice applies only to products that carry the CE mark:

Notice:

This is a class A product. In residential areas it may cause radio 

interference, in which case the user may be required to take adequate 

measures to reduce interference.

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  Kyoto 600-8530 JAPAN

  Ayabe Factory

  3-2 Narutani, Nakayama-cho,

  Ayabe-shi, Kyoto 623-0105 JAPAN

TRACEABILITY INFORMATION:

Representative in EU:

  Omron Europe B.V.

  Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

2279583-4D

Beware of danger of burns.

Do not touch the case while the Lighting is ON or immediately 

after the power is turned OFF, since it is extremely hot.

Connection with lighting controller 

Mounting

Align the positions of "the tab of the connector at the lighting 

cable" and "protrusion of the lighting connector at the lighting 

controller", and then insert it until it clicks.

Removing

Hold "the tab of the connector at the lighting cable" in the arrow 

(

) direction and pull it straight.

Note

Do not pull out with excessive force without pressing the tab.

Before mounting

Lighting controller side

Lighting controller side

Lighting side

Lighting side

After mounting

Before removing

After removing

Reviews: