background image

 

Solid-state Timer

 H3BA-N

1

Solid-state Timer

H3BA-N

Solid-state Timer with Valuable Multiple-time 
Ranges and Multiple-operating Modes

• Handles a wide range of applications through six operating 

modes.

• With H3BA-N8H models, the output type can be switched 

between time-limit DPDT and time-limit SPDT + instantaneous 
SPDT using a selector.

• Setting rings (order separately) to enable consistent settings 

and to limit the setting range.

• Panel Covers (order separately) to enable various panel 

designs.

• Conforms to LR and approved by UL and CSA.

RC

Broad Line-up of H3B

@

-N Series

H3B

@

-N

Multi-functional Timer

H3BA-N
H3BA-N8H

Twin Timer

Star-delta Timer

H3BG-N8
H3BG-N8H

Power OFF-delay Timer

H3BH-N8

H3BH-N

H3BG-N

H3BF-N

H3BA-N

Note: 

Refer to the 

H3BF-N/BG-N/BH-N Datasheet (Cat. No. L094-E1-1)

 for details.

11-pin model
8-pin with 
instantaneous 
contact output
and time-limit
output

8-pin with 
instantaneous 
contact output

H3BF-N8

8-pin model

8-pin model

8-pin model

Please read and understand this catalog before purchasing the products. 
Please consult your OMRON representative if you have any questions or 
comments. Refer to 

Warranty and Application Considerations

 (page 20), 

and 

Safety Precautions

 (page 16).

Summary of Contents for H3BA-N

Page 1: ...forms to LR and approved by UL and CSA RC Broad Line up of H3B N Series H3B N Multi functional Timer H3BA N H3BA N8H Twin Timer Star delta Timer H3BG N8 H3BG N8H Power OFF delay Timer H3BH N8 H3BH N H3BG N H3BF N H3BA N Note Refer to the H3BF N BG N BH N Datasheet Cat No L094 E1 1 for details 11 pin model 8 pin with instantaneous contact output and time limit output 8 pin with instantaneous contac...

Page 2: ...ontact output Time limit SPDT and switchable SPDT time limit instantaneous 110 VAC 50 60 Hz H3BA N8H 110 VAC 220 VAC 50 60 Hz H3BA N8H 220 VAC 24 VDC H3BA N8H 24 VDC Name specifications Models Flush Mounting Adapters Y92F 30 Y92F 70 Y92F 71 Mounting Tracks 50 cm l 7 3 mm t PFP 50N 1 m l 7 3 mm t PFP 100N 1 m l 16 mm t PFP 100N2 End Plate PFP M Spacer PFP S Protective Cover Y92A 48B Track Mounting ...

Page 3: ...ntaneous Mounting method DIN track mounting surface mounting and flush mounting Approved standards UL508 CSA C22 2 No 14 Conforms to LR currently under application and approval is expected by the end of Feb 2006 Time unit s sec min h hrs 10 h 10 h Setting 1 2 0 05 to 1 2 0 12 to 1 2 1 2 to 12 3 0 3 to 3 3 to 30 12 1 2 to 12 12 to 120 30 3 to 30 30 to 300 Item H3BA N H3BA N8H Rated supply voltage S...

Page 4: ...th 0 75 mm single amplitude each in three directions Malfunction 10 to 55 Hz with 0 5 mm single amplitude each in three directions Shock resistance Destruction 1 000 m s2 approx 100G each in three directions Malfunction 100 m s2 approx 10G each in three directions Ambient temperature Operating 10 C to 55 C with no icing Storage 25 C to 65 C with no icing Ambient humidity Operating 35 to 85 Life ex...

Page 5: ...ut circuit AC DC input Power supply circuit Oscillation circuit Time range unit selectors Counting circuit Output circuit Output type selector Indicator circuit Power ON indicator Output ON indicator H3BA N8H Inputs Start Starts time measurement Reset Interrupts time measurement and resets time measurement value No time measurement is made and control output is OFF while the reset input is ON Gate...

Page 6: ...ht part within the plastic frame of the time setting knob Setting of Time Use the time setting knob to set the desired time Using the Setting Ring Setting a Specific Time Mount the Panel Cover on the Timer set the desired time with the time setting knob and place Time Setting Ring A onto the time setting knob so that the time setting notch of Time Setting Ring A is in the center of the reset lock ...

Page 7: ...relay NO 1 and 3 11 and 9 and output indicator Power indicator t t Basic operation Power Start Output t t t t t t t t t a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay NC 1 and 4 11 and 8 Output relay NO 1 and 3 11 and 9 and output indicator Power indicator Basic operation Power Start Output t t t t t t t t t a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 11 and 8 ...

Page 8: ... t t a t a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 11 and 8 NC Output relay NO Output indicator 1 and 3 11 and 9 Power indicator Power Start Output t Basic operation t t t t t a t a Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 11 and 8 NC Output relay NO Output indicator 1 and 3 11 and 9 Power indicator Power Start Gate Reset Output relay ON OFF ON OFF ...

Page 9: ... and 5 1 and 4 Output relay NO 8 and 6 1 and 3 and output indicator Power indicator t t Rt Rt t a Operating mode Timing chart H ON delay with instantaneous output contact Power Output t Basic operation Power 2 and 7 Output relay 8 and 5 NC Power indicator Instantaneous 1 and 4 output relay NC t t Rt Rt t a Instantaneous 1 and 3 output relay NO Output relay 8 and 6 NO output indicator ...

Page 10: ...Y92F 30 Flush Mounting Adapter 48 48 11 pins 15 6 63 7 0 7 39 dia 44 8 44 8 78 13 6 PW UP 48 48 8 pins 15 6 63 7 0 7 39 dia 44 8 44 8 78 13 6 PW UP Time setting ring Panel cover 50 16 5 50 42 dia Panel Cutout Note The mounting panel thickness should be 1 to 5 mm 0 5 R max 45 0 6 0 N 45 0 6 0 58 52 42 48 Panel P3G Back Connecting Socket sold separately PW UP ...

Page 11: ...nce value Flush Mounting Panel 88 58 45 0 15 45 0 15 Panel Cutout Adapter mounting hole Two 4 5 dia 52 to 53 76 0 2 65 to 66 R0 5 max PW UP Panel 43 0 2 58 50 0 2 0 56 68 R0 5 max 45 0 5 0 55 0 5 0 Note The mounting panel thickness should be 1 to 3 2 mm 45 0 2 PW UP 112 2 109 9 2 3 H3BA N P2CF 11 H3BA N8H P2CF 08 101 3 99 2 3 H3BA N Adapter Y92F 30 P3GA 11 91 4 15 H3BA N8H Y92F 30 P3G 08 15 86 4 ...

Page 12: ...M4 40 0 2 Eight M3 5 7 5 sems Two 4 5 dia holes 70 max 50 max 20 3 max 7 8 3 4 5 35 4 4 Two 4 5 dia holes Eleven M3 5 7 5 sems 70 max 50 max 31 2 max 7 8 3 4 5 35 4 4 P3G 08 P3GA 11 Terminal Arrangement Internal Connections Bottom View 45 27 dia 45 4 9 17 45 45 27 dia 25 6 4 5 16 3 6 2 PFP 100N PFP 50N PFP 100N2 L Length 1 m PFP 100N 50 cm PFP 50N 1 m PFP 100N2 4 5 15 25 25 25 25 10 10 L 7 3 0 15 ...

Page 13: ...n three colors Use the most suitable type of Panel Cover with the design of the scaling plate according to the application When setting a given time for the Timer use of the Y92S 27 or Y92S 28 Time Setting Ring facilitates the time setting operation and minimizes possible setting errors by operators The Time Setting Ring and Panel Cover should be used as a pair Hold down Clip PFP M 50 11 5 M4 8 pa...

Page 14: ...al timers are shown as follows The contact symbol of the H3BA N is ex pressed as follows because of its multiple op erating modes The instantaneous contacts of conventional timers are shown as follows Power supply MODE See note A H Note The output contact can be set to either instantaneous or time limit contact using the output type selector located at the upper right corner of the front panel ...

Page 15: ...hen OFF 200 kΩ min Use contacts which can adequately switch 0 1 mA at 5 V No contact Input Connection to NPN open collector output sensor Contact Input No contact Input Connection to a voltage output sensor 12 to 24 VDC sensor power supply Sensor Timer Start reset gate Input 0 V No 2 pin Operates with transistor ON DC power supply Timer Start reset gate Input 0 V No 2 pin Operates with relay ON 12...

Page 16: ...pplied the internal components may be damaged The internal element varistor will be damaged if a voltage of higher than 100 VAC is applied to the 24 VDC line Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately or the Timer may not be reset or a timer error could result A DC power supply can be connected if its ripple factor is...

Page 17: ... Timer in order to prevent the Timer from malfunction and damage A diode is an example of a surge absorbing element for DC circuits and a surge absorber is an example of a surge absorbing element for AC circuits Do not leave the Timer in time up condition for a month or longer in places with high temperatures otherwise the internal parts such as an electrolytic capacitor of the Timer may be damage...

Page 18: ...ia max multi conductor cable or 3 dia max insulated stranded wire for wiring When the Y92F 40 Y92F 70 or Y92F 71 Flush Mounting Adapter is used just insert the Timer into the square panel hole If the panel coating is too thick and the hooks do not click spread open the hooks appropriately to the left and right after inserting the Timer to the hole Dismounting Surface Mounting with P2CF Panel Mount...

Page 19: ...Solid state Timer H3BA N 19 ...

Page 20: ...LE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to ...

Reviews: