background image

Number of presets

One

Two (Non-independent)

Display type

6 digit LCD, backlit

6 digit LCD, backlit

Input type

No-voltage

Voltage

No-voltage

Voltage

Contact output

H7CR-B

H7CR-BV

H7CR-BW

H7CR-BWV

Transistor output

H7CR-BS

H7CR-BVS

H7CR-BWS

H7CR-BWVS

Contact output

H7CR-BG

H7CR-BVG

H7CR-BWG

H7CR-BWVG

Transistor output

H7CR-BSG

H7CR-BVSG

H7CR-BWSG

H7CR-BWVSG

Counter supply voltages

100 to  240 VAC, 50/60 Hz or 24 VAC/12 to 24 VDC

Compact 1/16 DIN Counters with Easy-to-Use
Functions, Four- or Six-Digit LCD Displays

Designed for easy operation

High-speed response —
5 K counts per second

Prescale function displays
in units of actual physical
parameters — length, volume, etc.
(except A/SA types)

H7CR-C and -SC provide large/
small discrimination mode ideal
for positioning and production control

Easy-to-read backlit LCD display

On-line change of set value

4-level key protect

H7CR-S short 64 mm (2.52 in) body

Number of presets

One

Display type

6 digit LCD, not backlit

Input type

No-voltage

Voltage

Contact output

H7CR-A

H7CR-AV

Transistor output

H7CR-AS

H7CR-AVS

Sensor power supply

Not available

Not available

Counter supply voltages

100 to 240 VAC, 50/60 Hz or 24  VAC

Ordering Information

When placing your order, specify the supply voltage after the part number. For example, H7CR-B 100 to 240 VAC.

ECONOMY COUNTERS

STANDARD COUNTERS

Number of presets

One

Two (Non-independent)

Display type

4-digit LCD, backlit

4-digit LCD backlit

Input type

No-voltage

No-voltage

Sensor supply voltage

12 VDC

24 VDC

12 VDC

24 VDC

Output type

Contact output

H7CR-B4

H7CR-B4G

H7CR-B4W

H7CR-B4WG

Counter supply voltage

100 to 240 VAC, 50/60 Hz

12 VDC sensor
supply voltage

24 VDC sensor
supply voltage

Digital Counter

   H7CR

®

Summary of Contents for H7CR-11

Page 1: ...for positioning and production control Easy to read backlit LCD display On line change of set value 4 level key protect H7CR S short 64 mm 2 52 in body Number of presets One Display type 6 digit LCD n...

Page 2: ...SORIES 12 VDC sensor supply voltage 24 VDC sensor supply voltage Description Part number Sockets 11 pin Bottom surface or track mounting top screw terminals P2CF 11 Bottom surface or track mounting to...

Page 3: ...r 9 999 0 001 to 99 999 Decimal point None Rightmost 3 digits adjustments Sensor power None 12 or 24 VDC model specific supply Input signals Count reset Count reset key protect Input method No voltage...

Page 4: ...ng to C R and Q operation operation P and Q operation resets resets resets Scaling function None 0 001 to 99 999 for 6 digit 0 001 to 9 999 for 4 digit Decimal point None Rightmost 3 digits adjustment...

Page 5: ...ermissible ripple 20 max permissible ripple 20 max Operating voltage range 85 to 110 of rated voltage Power consumption Approx 1 7 VA at 50 Hz Approx 6 6 VA at 50 Hz 240 VAC 3 2 W at 24 VDC 240 VAC 0...

Page 6: ...et 20 ms 1 or 20 ms 1 or 20 ms power reset 0 5 s Key protect Not applicable Response time 1 second One shot durations 10 50 100 200 10 50 100 200 and 500 ms 10 50 100 200 and 500 ms and 500 ms separat...

Page 7: ...or phase difference inputs accepted Maximum counting speed 5 kcps Reset Present value reset to zero in Up or Up Down modes to preset with 1 stage models in Down mode and to preset 2 for 2 stage models...

Page 8: ...e Down decrement mode Up Down A Command input mode Up Down B individual input mode H L CP2 Count H L CP1 0 1 2 3 2 1 2 3 A A H L CP2 Count H L CP1 0 1 2 3 2 1 1 2 3 2 H L H L 0 1 2 3 1 2 3 BB B B Coun...

Page 9: ...and goes OFF after expiration of the one shot period for Output 2 One shot time periods for Output 1 and 2 are independent Up Down Reversible A B and C One shot output from Output 1 Sustained output...

Page 10: ...stained output Up Down Reversible A B and C Output Mode K Present value runs continuously Output 1 latches ON at preset 1 and goes OFF after expiration of the one shot period for Output 2 One shot tim...

Page 11: ...ed output One shot outputs can be set to 10 50 100 200 or 500 ms One shot output from Output 2 Sustained output Output Mode Q Present value runs continuously through one shot time period and returns t...

Page 12: ...ge Output 1 goes ON for one shot whenever present value is equal to preset 1 Output 2 goes ON for one shot whenever present value is equal to preset 2 Output Mode D Present value increments and decrem...

Page 13: ...output One shot output Sustained output level input One shot outputs can be set to 10 50 100 200 or 500 ms Notes Counting inputs are not acknowledged while the reset input is ON The compensation inpu...

Page 14: ...ax 1 97 Eight M3 5 x 7 5 sems 3 0 12 4 5 0 18 20 3 max 0 80 Two 4 5 dia or two M4 socket mounting holes Surface Mounting Holes 4 0 16 Terminal Arrangement Internal Connections Top View 40 0 2 1 57 70...

Page 15: ...o 4 5 dia holes 4 0 16 3 0 12 4 5 0 18 35 4 1 39 31 2 max 1 23 Two 4 5 dia or two M4 socket mounting holes Surface Mounting Holes 40 0 2 1 57 50 max 1 97 P3GA 11 Back Connecting Socket Terminal arrang...

Page 16: ...dels 50 5 1 99 47 2 1 86 47 2 1 86 50 5 1 99 Y92A 48G Finger Safe Terminal for P3G A Conforming to VDE0106 P100 Twelve 6 4 dia holes 34 47 7 x 4 47 48 x 48 16 5 47 4 27 6 PFP 100N PFP 50N Mounting Tra...

Page 17: ...n the two retaining screws To release the adapter lift the tab at the rear of the adapter Several counters may be mounted close together using Y92F 30 adapter as shown here When mounting two or more c...

Page 18: ...nclude the following H7CR BW H7CR BWG H7CR B4W H7CR BWV H7CR BWVG H7CR B4WG H7CR CW H7CR CWG H7CR CWV H7CR CWVG 12 or 24 VDC sensor power supply 12 or 24 VDC sensor power supply Key protect CP1 input...

Page 19: ...CR CVSG Applicable models include the following H7CR BWS H7CR BWSG H7CR SBWSL H7CR BWVS H7CR BWVSG H7CR SCWSL H7CR CWS H7CR CWSG H7CR CWVS H7CR CWVSG Single Preset H7CR 8 H7CR 84 H7CR 8S Single Preset...

Page 20: ...output sensor powered by built in DC power source Counter Sensor CP1 CP2 reset etc Input use 0 V 12 or 24 VDC V 30 V max 0 V Contact Input Switch contact Counter CP1 CP2 reset etc Input use 0 V Solid...

Page 21: ...value 8 Display key switches to the setting displays For double preset counters it switches between set values 1 and 2 9 Mode key switches from run mode to function setting mode Changes items in the f...

Page 22: ...any settings before operating the counter Settings and display are possible with or without power supplied although power supply is required for inputs and outputs to operate Model H7CR A Economy type...

Page 23: ...nt speed H7CR B H7CR SB inputs Used to prevent counting H7CR C H7CR SC errors caused by input interference H7CR 8 H7CR 11 Press the increment keys to set the desired speed A k on the display indicates...

Page 24: ...re effective only after returning to the Run mode Changing the Set Value When changing the set value while the counter is operating an output will be produced if the set value ever equals the present...

Page 25: ...RESET key or a reset input 2 Press the MODE key to scroll successively through the items that can be set Release the MODE key to select the desired item 3 Changing the counting speed or another selec...

Page 26: ...ficient to start the counter due to the switching regulator contained in the counter s internal circuitry Connect the power supply voltage through a relay or switch in such a way that the voltage reac...

Page 27: ...p value is on hold Mode A can be used for a start signal for sequence control equipment Mode F Go to Mode F to monitor the number of overrun objects The process value is displayed normally It is possi...

Page 28: ...gh Ontario M1B 5V8 1 800 55 OMRON 416 286 6465 Cat No GC TMCN1 3 02 Specifications subject to change without notice Printed in the U S A OMRON ON LINE Global http www omron com USA http www omron com...