5 & 7.5 HP

Direct Drive Cyclonic

Dust Collectors

Oneida Air Systems, Inc.   1001 West Fayette St., Syracuse, N.Y.  13204

Phone 1-800-732-4065   315-476-5151   Fax 315-476-5044   www.oneida-air.com

Owner’s Manual

Summary of Contents for 5 & 7.5 HP Direct Drive Cyclonic Dust Collectors

Page 1: ...5 7 5 HP Direct Drive Cyclonic Dust Collectors Oneida Air Systems Inc 1001 West Fayette St Syracuse N Y 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual...

Page 2: ...e ofContents Page Read the entire Owner s Manual before installing or operating system I II III IV V VI VII VIII IX X XI XII XIII XIV 2 3 4 5 6 7 8 8 9 10 11 12 13 14 15 System Start Up Information Di...

Page 3: ...nual 4 Have a licensed electrician check current draw on motor with all gates open Current draw should not exceed maximum motor amperage OAS is not responsible for destroyed motors Caution The Direct...

Page 4: ...gases carbon monoxide can be drawn into the shop from furnaces water heaters or other appliances 2 External Cartridge Filters 3 External Tube Filter O A S 2002 c 5 7 5 HP Direct Drive Owner s Manual...

Page 5: ...filter media BIA ZHI 487 test Rated G Captures 99 of test material over 20 microns Captures 99 5 of test material between 0 2 2 0 microns 11 fpm face velocity Tube Filter Bags 2 Pleated Cartridges 260...

Page 6: ...39 1 4 62 73 1 8 12 12 32 1 8 O D of Mounting Ring 69 875 24 1 4 Bolt Holes 30 3 8 10 031 I D 7 64 I D 1 25 Flange Tube Filters Height for 8 bags Other heights available 131 w 55 gal steel drum 105 No...

Page 7: ...race for Cyclone Angle Ring to sit on 1 Choose the system orientation plenum can be on the right or the left of the cyclone Bolt together the stand using the cross bars and 3 8 x 1 bolts Note the cros...

Page 8: ...iron ring will be on top of the cross bars of the stand Put bead of silicone around inside edge of flange on the cyclone cone Then put bolt through flat washer then bolt through holes in both flanges...

Page 9: ...ocedures could result in serious injury or death Disconnect all power and discharge all capacitors before servicing Install and ground per local and national codes Consult a licensed electrician with...

Page 10: ...n plastic bucket and tube filter to fit properly underneath A well sealed plywood box will make a good plenum for air distribution through the tube filters Use plywood for the plenums Cut 12 dia holes...

Page 11: ...ring the blow off process Let dust settle into dust pan Unclip and dump out dust Filter removal is not required You can also run your fingers around the filter pleats to knock material down WARNING A...

Page 12: ...licensed electrician Ground Connect house ground wire to green chassis screw in motor wire housing box Motor Wire Box Green Chassis Screw 11 Top View Outlet Inlet O A S 2002 c 5 7 5 HP Direct Drive O...

Page 13: ...5 and 7 5hp direct drive dust collectors do not come wired or with an on off switch Because of the voltage and amperage requirements of the system an industrial switch must be used OAS offers Square...

Page 14: ...nd as a sealant Check for air leaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check fo...

Page 15: ...elow 420 microns in size 017 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an e...

Page 16: ...warrants In no event shall O A S s liability under this warranty exceed the purchase price paid for the product and any legal actions brought against Oneida Air Systems shall be tried in the State of...