Instruction Manual
Digital Fiber Amplifier
D2RF/D2GF Series
D2RF-TAN
Analog Output Model
D2RF-TAP
Thank you for purchasing the D2RF Series. We hope you are fully satisfied with this product and
enjoy it's performance.
Carefully read this instruction manual and keep it for future reference.
Safety Precautions
Carefully read and understand the safety precautions before operation.
The important information is provided to protect your health and property.
Do not apply any other installing or operating procedure other than that described in
this manual.
CAUTION
It is dangerous to wire or attach/remove the connector with the
power on. Make sure to turn off the power before operation.
Make sure to use the product with the protective cover attached
and closed.
Installing in the following places may result in malfunction:
1. A dusty or steamy place
2. A place generating corrosive gas
3. A place directly receiving water or oil mist.
4. A place that is subjected to heavy vibration or impacts.
The product is not designed for outdoor use.
Do not use the sensor in transient state after power on
(approx. 100 ms).
Do not wire with the high voltage cable or the power line.
Failure to do this will cause malfunction by induction or damage.
The sensor performance or digital display values may depend on
the individual units or the condition of detected product.
This product is not an explosion-proof construction. Do not use the
product in a flammable, explosive gas or liquid environment.
Do not use the product in water.
Do not disassemble, repair, or convert the product.
Failure to do this may cause failure, fire, or electric shock.
Operate within the rated range.
This product cannot be used as a safety device to
protect human body.
Model
Analog Output
Cable type
D2RF-TA (N/P)
Power source, voltage
12-24V DC ±10% including ripple
Consumption current
45mA or less / 24V (When not using analog output)
Response time
60
s / 250
s / 2 ms (Fast/Standard/Long)
Control output
NPN / PNP Open collector 100mA /
30V or less
Load current: 100mA or less
Residual voltage: 1.8V or less
Output method
Selectable Light on / Dark on
Short-circuit protection
Incorporated
Light source
Red LED
Indicator light / Display
Output Indicator: Orange / 7 segment / 8 digit display
Sensitivity setting
Teaching / Manual adjustment
Timer function
OFF, On delay timer, Off delay timer,
One-shot timer
Timer time
1ms - 9 sec.
Analog Output
4 to 20 mA
Operating
temperature/humidity
-25 ~ +55 C / 35 ~ 85% RH
o
No freezing and No condensation
Store temperature/
humidity
No freezing and No condensation
Shock resistance
10 ~ 55Hz Amplitude 1.5mm 2 hours for each
direction of X,Y and Z
Protective category
IP50
Material
Case: PPE, Cover: PC
Weight
70g (Including cable)
Part Description
Mounting Amplifier
Attaching to and Removing from DIN rail
Attaching the amplifier.
Attach the front of the amplifier onto the DIN rail
or mounting bracket. Press the back of the amplifier
down until it snaps into place.
Amplifier removal.
Push the amplifier in the direction of , lift the
front of the sensor and remove.
-40 ~ +70 C / 35 ~ 85% RH
o
How to connect the fiber cables
Open fiber lock lever.
Insert fiber into holes to stop.
Approximately 15mm guided by fiber sign
Return fiber lock lever until it stops.
When using diffuse reflection co-axial fiber cables the cable with the single core
or white line is the emitter, the multi-core fiber is the receiver.
How to use Fiber Adapter
Turn adapter cap completely counter-clockwise,
then insert the fiber.
Lock the cable by turning adapter cap clockwise.
Cut the excess fiber with fiber cutter.
CAUTION
Adapter cap
Cut position
Fine fiber
Optex-FA U.S. sales
Ramco Innovations
(800) 280-6933 www.optex-ramco.com