Placement

 

 

CS500B is intended for indoor use 
only;

 

its internal components are not 

sealed

 

from the environment. 

Please install CS500B in a protected 
environment away from excessive heat 
or excessive moisture. 
 

 

 

 

Charging the UPS first   

 

The battery is fully charged at the 
factory. However, user is recommended 
to charge the battery at least 4 (FOUR) 
hours before using UPS, since energy 
loss may have occurred during 
shipping or long duration storage. To 
recharge the battery, simply let UPS be 
plugged into an AC outlet. 

Connect Equipment to CS500B   

 
Battery Backup & Surge Protection Outlets 

These two outlets not only provide surge protection but also backup power for your 
equipment. In case of AC failure, battery power is automatically provided to two three 
outlets. Please connect your main devices to these outlets. 

Surge Protection Outlets 

These two outlets provide surge protection but do not provide power during AC failure. 
 

               

 

 

Turn on the UPS 

 

The UPS can be turned on after connecting to the utility power. After the UPS is turned 
on, it conducts a self-test and enters normal mode. Pressing the power button for 1 second 
under normal mode will also enable the self-test function. The silence function can be 
enabled/disabled by pressing the power button for 1 second in backup mode. In addition, 
the power button can be used as the master on/off switch for your equipment by leaving 
your equipment connected to UPS and switched on. To turn off the UPS, please press 
power button until buzzer stops (about 2 seconds). 

 

LED Indicators & Alarms 

 

 

 

 
 
 
 
 

AC mode

Green LED ON

None

Battery fault

Red  LED flashes once

every 0.5 sec

None

Overload

Red LED ON

ON

Backup

mode

Yellow  LED flashes

once every 4 sec

Buzzes once every 4 sec

Battery low

Yellow  LED flashes

once every 1 sec

Buzzes once every 1 sec

Charger

abnormal

Green LED ON

Buzzes once every 0.5 sec

 

Battery Replacement Procedure 

 

Note: Follow this procedure for safe replacement of the battery. However, small sparks may occur 
during the process. This is normal. 

 

         

 

 
                         
 
 

 

 

 

4. 

Connect the wires to the new battery making sure that the red wire is connected to the red battery 

terminal and the black wire is connected to the black battery terminal. 

5. Reverse the procedure from 3 to 

1. 

 

www.opti-ups.com 

CS500B 

User Manual

 

Data Line Surge Protection 

 

CS500B’s exclusive communication protection ports will protect 
any standard modem, PBX System or 10/100 BaseT connection 
ports. This communication port can accommodate either the 
phone (RJ-11) or network (RJ-45) jack. 

 

 

 

USB Communication Port 

 

Please link CS500B USB port with computer USB 
port using the USB cable which is attached inside the 
box. Now, you can use the software (OPTI-SAFE 
SENTINEL) to control your computer and CS500B. 

 

Install Software   

 

Make sure your communication cable is connected to 
your UPS as shown in the left picture.

 

To install the software, follow the steps below. 
Simply insert software CD into your computer, and 
the install process will begin. If not, run Setup.exe 
from the CD manually. 

Wall Jack 

TEL / FAX / 

Modem / LAN 

USB Port of 

Computer 

Circuit Breaker 

 

The circuit breaker button is located at the side 
of CS500B. It will stick out to disconnect itself 
from the utility power when an overload 
condition occurs. If the button sticks out, 
disconnect nonessential equipment. Reset the 
circuit breaker by pushing the button inward. 

 

 

AC mode 

Battery 

Backup 

Battery 

Fault/ 

Over 

Load 

Circuit Breaker 

ON/OFF 
Test 
Silence 

1. 

Remove the two screws on the 
bottom of UPS

2. 

Pull and open the battery cover. 

3. 

Pull out the battery and disconnect the 
two wires connecting the battery to 
the UPS.

 