User Guide 

 
 

 

 

 
 
 
 

 

 
 
 

GS 1100B 

Summary of Contents for Gaming Series GS1100B

Page 1: ...I User Guide GS 1100B ...

Page 2: ......

Page 3: ...f your UPS is on the rear panel You should note the serial number in the space provided below Retain this booklet as a permanent record of your purchase to aid in identification in the event of theft or loss Model No Serial No Purchase Date ...

Page 4: ...s not cover 1 Any product on which the serial number has been defaced modified or removed 2 Damage deterioration or malfunction resulting from a Accident misuse neglect fire water or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product b Repair or attempted repair by anyone not authorized by Opti c The fault is the result of accidental ...

Page 5: ... PARTIES OR OTHER COMMERCIAL LOSS EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES 2 ANY OTHER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE 3 ANY CLAIM AGAINST THE CUSTOMER BY ANY OTHER PARTY Effect of state law for US This warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow limitations on implied warranties...

Page 6: ...A BATTERY CAN PRESENT A RISK OF ELECTRICAL SHOCK BURNS FROM HIGH SHORT CIRCUIT CURRENT FIRE OR EXPLOSION FROM VENTED GASES OBSERVE PROPER PRECAUTIONS WHEN REPLACING BATTERIES USE THE SAME NUMBER AND THE FOLLOWING TYPE BATTERIES SEALED LEAD ACID MAINTENANCE FREE PROPER DISPOSAL OF BATTERIES IS REQUIRED REFER TO YOUR LOCAL CODES FOR DISPOSAL REQUIREMENTS ...

Page 7: ... intended for installation in a temperature controlled indoor area free of conductive contaminants The socket outlet shall be installed near the UPS and easily accessible With the installation of the UPS it should be prevented that the sum of the leakage current of the UPS and the connected consumer exceeds 3 5mA The battery supply should be disconnected in the plus and minus pole at the quick con...

Page 8: ...eption which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or a...

Page 9: ...ication Port 12 2 6 AC Input 12 2 7 Output Outlet 12 3 INSTALLATION AND OPERATION 3 1 Unpacking and Inspection 13 3 2 Placement 13 3 3 Determining How Much Equipment You 14 Can Connect to Your UPS 3 4 Powering Up Your UPS 14 3 5 Connecting Your Equipment to the UPS 14 3 6 Operation and Functional Test 15 3 7 Storage Instructions 16 4 SPECIFICATIONS 4 1 Electrical Specifications 16 4 2 Mechanical S...

Page 10: ...hance Series Block Diagram 1 2 Frequency Auto Sensing The GS models can operate in either a 50 or 60 Hz environment When you plug the UPS into an AC outlet and turn it on it will automatically detect the incoming line frequency and configure itself to match that frequency 1 3 Smart Buck and Boost Line Conditioning The voltage from your AC power source can fluctuate above and below the standard rat...

Page 11: ...Communicate with Computer Many UPS provide only a basic power failure warning These models together with OPTI SAFE Sentinel also provide you with important operating information From your computer screen you can know input output voltage and current frequency battery voltage etc and analyze power problems If software is not part of your UPS package you can purchase it from your local dealer 1 6 Sc...

Page 12: ...10 2 UPS CONTROLS 2 1 External Views Front Panel Rear Panel ON OFF TEST SILENCE AC Mode Battery Mode Battery Fault ...

Page 13: ... is operating while the UPS is in back up mode Once normal utility power returns the unit will wake up automatically You can disable the No load shut down function by pressing the power button until you hear two beeps 2 3 Audible Alarm 1 BACKUP mode When the UPS is working under Battery mode the UPS will emit an audible alarm The alarm beeps every 2 seconds The alarm stops when the UPS returns to ...

Page 14: ...tware communication software you will have access to important operating information From your computer screen you can monitor input output voltage AC frequency battery voltage etc and analyze power problems Software will also initiate automatic graceful shutdowns during extended power failures If software and a communication cable are not included in your UPS package you can purchase it from your...

Page 15: ...munication Cable 1 Telephone Line 1 3 2 Placement 1 This unit is intended for indoor use only Although your UPS is very rugged its internal components are not sealed from the environment 2 The UPS must be installed in a protected environment away from heat emitting appliances such as a radiator or heater Do not install this product where excessive moisture is present 3 The location should provide ...

Page 16: ...20V x 2 7A 324VA 120V x 2 0A 240VA Add up the VA requirements for each device for example 324VA 240VA 564VA 4 Make sure that your UPS has at least as much VA capacity as your equipment requires 3 4 Powering Up Your UPS 1 Connect the power cord to a verified grounded 3 wire receptacle 2 Power up the UPS by pressing the On Off button for 3 seconds 3 We recommend that you charge the battery for six 6...

Page 17: ... To test the backup function you may unplug the power cord of the UPS or simply press the Test Button on the front panel During this test observe that your equipment operates properly and without interruption If you leave your UPS on continuously it is a good idea to perform a Test at least once a month If you unplug the power cord all models will beep once every 4 seconds You can press the Test B...

Page 18: ...equency Input AC mode 45Hz 55 Hz 55 Hz 65 Hz Output Inverter mode 50 Hz 60 Hz 0 1 Hz Wave Form AC Mode sine wave Back Up Mode step wave Transfer time Power Failure AC Inverter 4 ms typical Spike Surge protection Version Continuous Single pulse 8 20us Voltage Vrms Imax Joules 110 120V 175V 10 000A 1050 220 230 240V 385V 10 000A 1050 Audible Alarm Battery discharge at power failure Beep every 2 seco...

Page 19: ...x102x165 7 6 7 9 4 3 Environmental Specifications Operating Storage and Shipment Temperature 0 40 C 32 104 F 20 60 C 4 140 F Humidity 0 95 non condensing 0 95 non condensing Altitude 3 000 m 10 000 ft Max 12 000 m 40 000 ft Max 5 TROUBLESHOOTING The TROUBLESHOOTING CHART below covers most of the difficulties that you may encounter under normal working conditions If the UPS fails to operate properl...

Page 20: ...ng Battery is not fully charged or the battery is dead Recharge the battery for 8 hours and retest the backup time UPS is normal but the computer won t turn on Computer input power cord is loose or not connected Reconnect computer input power cord Wrong interface cable Purchase the correct one from your distributor Software communication not working The serial port of the computer has not been con...

Page 21: ...nly by factory trained service personnel CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects 2 Use tools with insulated handles CAUTION Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries They ...

Page 22: ...tion 6 1 before performing the following steps 1 Remove the two screws on the battery cover 2 Pull and open the cover Gently pull out the battery 3 Disconnect the two wires connecting the battery to the UPS 4 Connect the wires to the new battery making sure that the red wire is connected to the red battery terminal and the black wire is connected to the black battery terminal 5 Push the new batter...