background image

33.

Specifications

Features

DS10KB-RM

Front Panel

DS10KB-RM

Rear Panel

* DS10KB-RM

* Online double conversion design
* Pure sine wave output with less than 3% THD
* Fully digitized microprocessor control
* Power factor correction
* Selectable UPS output voltage
* High efficiency mode
* Cold start function (DC power on)
* Emergency power off function (EPO)

DS10KB-RM

* Short circuit and overload protection
* Fax/Modem/LAN data line surge protection
* Advanced battery management (ABM)
* Automatic battery charging in UPS OFF mode
* Automatic diagnostics and battery check-up
* Extended battery pack available
* Multilanguage LCD display
* RS232 and USB Communication ports, 
  UPS monitoring software

 

Line Interactive 

UPS Series

On Line UPS

Series

A

VR Series

Inverter Series

Surge Series 

Standby UPS

Series

Networking

Series

Green Power

 Series 

windows

2000 / XP

2003 / Vista

Sine Wave

DS10KB-RM 

Topology
On-battery Output Waveform
Number of Phase
INPUT
Maximum Capacity
Nominal Input Voltage
Input Voltage Regulation
Nominal Input Frequency
Input PFC
Input Short Protection
OUTPUT
Nominal Output Voltage
Output Voltage Regulation
Output T.H.D
High Efficiency Mode (AC to AC)
Crest Factor
Start on Battery
Auto Restart
PROTECTION
Data Line Surge Protection
BATTERY
User Replaceable Batteries
Typical Backup Time (Full / Half load)
Recharge Time to 90%
Connected Battery Pack
ADVANCED WARNINGS / DIAGNOSTICS
Front Panel LEDs
Audible Alarms
COMMUNICATION INTERFACE
Communication Port
SNMP Manageable 
ENVIRONMENTAL
Operation Temperature
Storage Temperature
Relative Humidity
Audible Noise
PHYSICAL
Dimensions (Physical / Packing)              (in)
(LxWxH)                                                (mm)
Weight (Net / Gross)                               (lbs)
                                                                (kg)
Battery Pack (Net / Gross)                      (kg)
Battery Pack Dimensions                         (in)
                                                              (mm)  
CONFORMANCE
EMI / RFI Compatibility
Safety Certifications

Model Name

True On-Line, Double Conversion

Pure Sine Wave 

Single Phase (2W+G)

10000VA/7000W

208/220/230/240Vac

176-276Vac

50Hz / 60Hz Auto Sensing 

 0.97@Full load

Circuit Breaker

208/220/230/240Vac (selectable)

Rated V/-2%

 3% T.H.D at Linear Load 

 92%

3 : 1

Yes
Yes

RJ11 / RJ45

240V / 12V34W × 20 (in Battery pack)

12/24 min

4 Hours

BP10000-RM

AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters

Battery mode / UPS faults / Overload

RS232 and USB Port

Yes

0~40°C / 32~104°F

-20~60°C / -4~140°F

0~95% humidity, non-condensing

<40dBA (at 1 meter from surface of unit)

23.5×16.9×5.1 / 29.1×22×10.7

                                                                                             597×428×130 / 740×560×273                                                                                             

44.1 / 52.9

                                                                                                                           20 / 24                                                                                                                             

66 / 75.5

23.5×16.9×5.1 / 29.1×22×10.7

                                                                             597×428×130 / 740×560×273                                                                             

CE; GOST-R

C-Tick, A-Tick; GOST-R

RS232 

EPO

Input

External

Battery

Connector

Communication

Port

Reviews: