Page 1: ...OPL 9712 Barcode Data Collector Specifications Manual ...

Page 2: ...that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental damag...

Page 3: ... 9 8 1 Print Contrast Signal PCS 9 8 2 Scan Area and Resolution 9 8 3 Pitch Skew and Tilt 11 8 3 1 Pitch Angle 11 8 3 2 Skew Angle and Dead Zone 12 8 3 3 Tilt Angle 13 8 4 Curvature 14 9 Interface Specifications 15 9 1 Bluetooth Specifications 15 9 2 Frequency 16 9 3 Infrared Transmission IrDA 16 9 3 1 Specifications 16 9 3 2 Transmission speed 16 10 Default Settings 17 10 1 Default Settings 1 Rea...

Page 4: ...t Practices 25 17 Safety 26 17 1 Shock 26 17 2 Temperature Conditions 26 17 3 Foreign Materials 26 17 4 Other 26 18 Mechanical Drawing 27 Table of Figures Figure 1 Reading a barcode 6 Figure 2 Ambient Light Immunity 7 Figure 3 The depth of field 9 Figure 4 Pitch 11 Figure 5 Skew and dead zone 12 Figure 6 Tilt angle 13 Figure 7 Curvature 14 Figure 8 Serial number diagram 19 Figure 9 FCC label 20 Fi...

Page 5: ...417 Chinese Post PDF417 Codabar NW 7 Code 11 Code 39 Code 93 Code 128 EAN 128 Composite Codes UCC EAN 128 incl CC A B C IATA Industrial 2of5 Interleaved 2of5 ISBN ISSN Korean Postal Authority Code Matrix 2of5 MSI Plessey UK Plessey RSS all incl CC A B RSS 14 RSS Limited RSS Expanded S Code Telepen Tri Optic Require use of an external library Using the built in clock function you can add a time sta...

Page 6: ...g the Software Development Kit SDK Software can be developed in the C programming language These development tools are available as accessories Figure 1 Reading a barcode 3 Physical Features 3 1 Dimensions W 129 mm x D 44 mm x H 22 3 mm 3 2 Weight 105 grams with lithium ion batteries installed ...

Page 7: ...ormance is guaranteed when the range of illumination on a barcode surface is between zero and the following values Incandescent light 3 000 lx Fluorescent light 3 000 lx Sunlight 50 000 lx Figure 2 Ambient Light Immunity Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 25 mm Symbology 8 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Direct light or specular reflection lig...

Page 8: ...arks MPU 16 bit CISC CPU Manufactured by Toshiba Control section Clock frequency 14 74 MHz Flash ROM 512 KB For BIOS AP External memory SRAM 512 KB For WORK DATA LCD Semi transparent dot matrix LCD DPI 112 x 64 dpi Backlight Installed Display section Functions Clock time battery power failure notification function settings Clock section Real time clock Counts year month date hour minute of the cur...

Page 9: ...of reflectivity of space and quiet zone PCS is determined by Reflectance of white bar Reflectance of black bar Reflectance of white bar 8 2 Scan Area and Resolution The depth of field is measured from the edge of the data collector The scanning range is within the circular arc centered on the scan origin 1 2 3 5 8 AB C DEF JKL T UV 6 M N O 9 WXYZ 7 4 G H I P Q RS C LR BS Sh i f t 0 E NT M in i mu ...

Page 10: ... Digit 1 0 mm Code 39 0 9 1 0 5 mm Code 39 0 9 3 0 25 mm Code 39 0 9 8 0 15 mm Code 39 0 9 10 Conditions Scan angle 54 reading range is 44 Detect angle 40 Barcode sample Resolution 0 25 mm OPTOELECTRONICS test sample Code 39 9 digits Distance Within 90 mm from the minimum scannable distance Note dirt or scratches on the mask will degrade scanning performance Always handle the data collector carefu...

Page 11: ...Opticon OPL 9712 Specifications Manual 11 8 3 Pitch Skew and Tilt 8 3 1 Pitch Angle Scanning performance is guaranteed at α 25 Figure 4 Pitch ...

Page 12: ...8 3 2 Skew Angle and Dead Zone Skew angle β 50 Excluding dead zone Dead zone β 8 There are some areas in which decoding fails due to specular reflection Depth of field Within 90 mm from the minimum scannable distance Figure 5 Skew and dead zone ...

Page 13: ...Sample OPTOELECTRONICS Test Sample Distance 90 mm from the edge of the data collector Label Pitch Skew Angle PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Dead Zone Tilt Angle PCS 0 9 Resolution 0 26 mm Symbology 13 digit JAN Quiet Zone 10 mm Angle Curvature R Skew Angle β 15 for measuring Pitch Angle and Tilt Angle ...

Page 14: ...mm With 13 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 20 mm Figure 7 Curvature Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 26 mm Quiet Zone 10 mm Distance 90 mm from the edge of the data collector Angle Skew Angle β 15 The scanning range will vary according to the depth of field ...

Page 15: ...can be configured using menu barcodes Encryption Encryption is linked to the authentication setting and cannot be enabled or disabled separately Communication range 3 Approximately 10 meters Frequency 2400 MHz to 2483 5 MHz Transmission power 2 5mW 4dBm or less Comm range 10 m Baud rate 115 2 kbps Antenna 1 4λ surface mounted Notes 1 The OPL 9712 complies with Bluetooth standards The device that c...

Page 16: ...example manufacturing lines at factories specific power saving radio stations requiring no license and amateur radio stations Interference from other devices may affect the communication speed or communication range of this scanner or vice versa 9 3 Infrared Transmission IrDA 9 3 1 Specifications Thee CRD 9723 cradle enable the OPL 9712 to perform infrared transmission of data with IrDA Ver1 2 low...

Page 17: ... UPC E Add on X X CR EAN 13 X CR EAN 13 Add on X X CR EAN 8 X CR EAN 8 Add on X X CR Chinese Post X X X CR Codabar NW 7 X X CR Not transmit ST SP Code 11 X X X CR Code 39 X X CR Not transmit ST SP Code 93 X X CR Code 128 X X CR EAN 128 X X X CR IATA X X CR Industrial2of5 X X CR Interleaved2of5 X X CR Korean Postal Code Code 3of5 X X X CR Matrix2of5 X X X CR MicroPDF417 X X CR PDF417 X X CR MSI Ple...

Page 18: ...SP Notes In the Reading column means Enable reading and X means Disable reading In the Transmit code length column means Transmit code length and X means Do not transmit code length In the Transmit CD column means Transmit check digit and X means Do not transmit check digit In the Calculate CD column means Calculate check digit and X means Do not calculate check digit means not supported In the Pr...

Page 19: ...con OPL 9712 Specifications Manual 19 11 Serial Number The serial number shown on the right is written on silver matte with black paper affixed to the backside of the OPL 9712 Figure 8 Serial number diagram ...

Page 20: ...mplies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Figure 9 FCC label ...

Page 21: ...ion Place the OPL 9712 in a protection bag E and pack it in the provided box Then place the accessories into the box Accessories 1 lithium ion battery 1 hand strap Close the box and affix a label to the side of the box Size of the package after assembly 245 W x 112 D x 39 H mm Figure 10 Individual packaging ...

Page 22: ...y 490 mm D by 195 mm H Note The RO mark labeled on the package tray or package box guarantees that the applicable product has passed our test of RoHS restrictions compliance the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC However this document does not have any legal weight in the European Union ...

Page 23: ...d velocity 19 6m s2 2G for 6 minutes in non operating state Repeat this routine 10 times in each of X Y Z direction for a total of 180 minutes 14 3 Dust and Drip Proof IP 54 15 Reliability MTBF Mean Time Between Failures of this product except for the laser diode and the mirror motor scan unit is 8 years MTBF of the laser scan engine includes the life cycle of the laser diode and mirror motor is 1...

Page 24: ...s B This is a Class B product to be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment VCCI If this is used near a radio or television receiver in a domestic environment it may cause radio interference Please install and use the equipment according to the instruction manual FCC Part 15 Subpart B ...

Page 25: ...ate label 16 4 1 Export Regulations This product is subject to the strategically controlled exports regulated under Foreign Exchange and Foreign Trade Laws Export of this product may require export permission from the Japanese government 16 5 RoHS RoHS The restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC 16 6 State of California Perchlorate B...

Page 26: ...ow the data collector into the fire Do not forcibly bend the cables at low temperatures 17 3 Foreign Materials Do not immerse the data collector in liquids Do not subject the data collector to chemicals 17 4 Other Do not plug unplug the connectors before disconnecting the power Do not disassemble this product Do not use the data collector near a radio or a TV receiver It may cause reception proble...