Model 96012
1
Watering stations
2
Indicates when next
watering cycle will start
3
Manual watering is on
4
How often timer will
water in interval mode
5
Cycle start times
6
Timer is in set mode
7
Rain delay is on
8
Timer is watering
1
Battery tray
2
LCD screen—displays setting and watering program for timer
3
Function dial—turns to set watering program
4
CLEAR button—clears individual settings of program
5
+ – buttons—advance or reverse settings
6
< > buttons—move cursor to different settings
7
ENTER/MANUAL button—selects setting or turns on rain
delay when in AUTO
8
RESET—clears all programmed settings
InstallatIon
1. Attach manifold to an outdoor hose faucet.
2. Secure manifold to wall using the mounting hardware and
instructions provided.
3. Attach up to 4 valves to the manifold outlets (the valves are
electronically operated and must be attached to the timer for
proper operation).
4. Connect the wire from each valve to one of the numbered ports on
the back of the timer. The numbers 1 through 4 are the “STATIONS”
used while programming your timer.
5. Install two AA alkaline batteries into the battery tray (battery tray
may be removed by pulling out to the left).
Please ensure that the valves are attached to the timer before installing
batteries. Once the batteries are installed the timer will immediately begin
a start-up sequence. A countdown from 150 down to 0 will begin on the
display and will take a few minutes. Your timer can be programmed during
the countdown, but the valves cannot be actuated until it is completed.
6. Create your timer program.
7. Slide timer onto the manifold mounting bracket.
8. Turn on hose faucet.
9. If valves are placed on the two outer positions on the manifold,
the manifold shut-off’s must be opened.
Mounting the Manifold to the Wall
1. Attach support rod to manifold by inserting it into the two mounting
holes on the back of the manifold.
2. Mark where support rod touches the wall.
3. Drill a pilot hole using a 6.35 mm drill bit.
4. Attach the support rod using the screw provided.
Installing The Batteries
1. Remove the tray on the side of the timer by sliding it out.
2. Insert two AA (1.5V) alkaline batteries (not included) and replace the tray
Low battery icon will appear when batteries need replacing. Replace
batteries within 30 seconds or timer programming will be lost.
Tip: Remove batteries when timer is not in use for extended periods.
ProgrammIng
Rotate the dial to positions indicated for setup.
1. Turn Dial to Set Clock
1. Press the + button to advance clock time (hold button for quick
advance). Press the – button to reverse clock time (hold button for quick
advance). *Keep in mind am/pm.
2. Press ENTER or turn the knob to accept clock time.
2. Turn Dial to Set Day
1. Use the < and > buttons to move cursor (blinking line) over current day.
2. Press ENTER or turn dial to accept the day.
3. Turn Dial to Start Time
Each start time cycles through all watering stations (1, 2, 3, and 4). Cycle A
is for if you want to water once a day. Add Cycle B if you want to water two
times a day (2 different start times). Add Cycle C if you want to water three
times a day (3 different start times).
1. Use < and > buttons to select start time A, B, or C.
2. Press ENTER to edit start time.
3. Use the + and – buttons to set desired start time.
* Keep in mind am/pm.
4. Press ENTER to accept the setting.
5. Repeat steps 1 through 4 for B and C if you want to water more than
once a day.
To clear a start time:
1. Use the < and > buttons to move the cursor over cycle letter (A, B, C).
2. Press ENTER to select.
3. Press CLEAR.
EXAMPLE: If cycle A is set for 6:00 am, then at 6:00 am your first valve will
turn on and run for its duration, then it will turn off and the second station
will automatically turn on and run for its duration.
4. Turn Dial to Run Time
Set watering duration from 1 to 240 minutes for up to 4 stations.
1. Use the < and > buttons to select the run time for valves stations
1, 2, 3, or 4.
2. Press ENTER after each selected Station. [ ] will appear around the
Stations selected to water.
3. Press CLEAR to deselect a Station.
Or
1. Use the + and – buttons to increase or decrease the number of
minutes to water.
2. Press ENTER to accept the setting.
3. Repeat steps 1 and 2 for each station you would like to water.
5. Turn Dial to How Often
Select which days to water or every 1 to 14 days. All stations and cycles
will water on selected days.
1. Use the < and > buttons to select which days to water Sunday
through Saturday.
2. Press ENTER after each selected day. [_] will appear around days
selected to water.
3. Press CLEAR to deselect a day.
Or select INTERVAL. 1 is every day, 2 is every other day etc. up to 14 days.
1. Use the + and – buttons to increase and decrease the number of days.
2. Press ENTER to accept the setting.
6. Turn Dial to Auto
Timer waters according to programmed start time(s), run time(s), on the
programmed days or interval; this is where you want the dial to have your
program run.
Manual Watering
Allows you to water immediately without interrupting the set cycle(s).
1. Press the MANUAL button when dial is turned to AUTO
2. Press ENTER to run all stations once as previously
programmed in RUN TIME section. Or, use the < and >
buttons to select which station(s) to manually water.
3. Press ENTER when cursor is over desired watering station.
4. Use + and – buttons to set from 1 to 240 minutes
* There will be a 6 second delay till your cycle will begin
Screen will flash between clock and minutes remaining
on cycle. To remove manual watering and resume
programmed cycle press CLEAR.
Rain Delay
Delay watering cycle during precipitation to conserve water.
1. When in AUTO, press + button for 24 hrs, 48 hrs, or 72 hrs.
Screen will flash between clock and hours remaining before
programmed cycle resumes. To remove rain delay, press CLEAR,
or turn dial to OFF and then back to AUTO.
Off
Off stops the timer from watering and clears Rain Delay.
troubleshootIng
Water does not come on at desired time. Check if:
■
Clock is set to correct time including AM and PM.
■
Start time is set to desired time including AM and PM.
■
Start times begin after previous watering cycle has run
through all stations and set durations.
■
Rain Delay is on (DELAY appears on left side of screen if on).
Timer does not water. Check if:
■
Timer is set to AUTO.
■
Batteries are low.
■
Clock is set to correct time including AM and PM.
■
Rain Delay is on (DELAY appears on left side of screen if on).
■
Valve plugs are inserted in the correct corresponding timer outlet.
Water won’t turn off. Check if:
■
Watering duration is set to desired time.
■
Start times begin after previous watering cycle has run
through all stations and set duration.
Working Water Pressure
Minimum: 172KPa Maximum: 690KPa
Working Temperature
Maximum: Do not exceed 48.9 °C
Minimum: Keep from freezing
Warnings:
For outdoor use with cold water only.
automatIc Yard
WaterIng sYstem
InstructIons
■
Controls up to 4 stations (comes with 2 valves
that control stations, purchase additional
valves separately).
■
Up to 3 start times per day (cycles A,B,C).
■
Waters from 1-240 minutes per start time
(per valve).
■
For outdoor use with cold water only.
4
3
2
1
1
2
3
4
6
5
7
8
PN 96012-24 rD
Orbit
®
Irrigation Products, Inc.
North Salt Lake, UT 84054 USA
© 2011 Orbit Irrigation Products, Inc.
All rights reserved. All trade names are registered
trademarks of respective manufacturers listed.
p 801 295 9820
f 801 951 5815
www.fluid-studio.net
1065 South 500 West
Bountiful, Utah 84010
proof no:
3
date: 02.15.11
des: SH spck: SH
job no: NA
client: Orbit
sku: 96012
upc: NA
file name: 96012-24 rA.indd
software: InDesign CS5
colors
additional instructions:
·
Font sizes cannot be smaller than 7 pt.
· Proofing Code:
·
color
non printing
PMS
????
PMS
????
color
non printing
PMS
????
Registration
K
Printers are responsible for
meeting print production
requirements. Any changes
must be approved by the
client and Fluid Studio.
printed piece must meet
designated specifications
on this form.
dimensions:
flat: w: 12" h: 9"
finished: w 3.0" d: " h 3.0"
© 2011 Fluid Studio. This
work is the property of Fluid
Studio, and cannot be used,
reproduced or distributed
in any way without their
express permission.
PN 96012-24 rA
9
Clock, start time, and
watering duration
10
AM or PM for clock
and start time
11
Low battery
12
Indicates numbers in clock
section as hours, minutes,
or days
13
Days of the week
14
Interval watering mode
Customer Service
1-801-299-5555
orbitonline.com
1
2
4
9
8
6
7
5
3
14
13
11
12
10
Product Includes:
A
(2) End Plugs
B
(1) #14 Round Head Screw
C
(1) 18.41 cm. Support Rod
C
A
B