Page 1: ...WS 7013U Wireless 433 MHz Temperature Station Instruction Manual Register your product on the web at WWW ORECK COM ...

Page 2: ...up Guide Battery Installation 5 7 Setting the Time 7 8 Selecting Units of Measurement 8 Features Minimum and Maximum Temperatures 9 Resetting Minimum and Maximum Temperatures 9 Mounting 9 10 Troubleshooting 10 12 Maintenance and Care 12 Specifications 13 14 Warranty Information 14 1 ...

Page 3: ...temperature sensor TX6U and mounting bracket Figure 2 3 3 1 2 Philips screws 4 One strip of double sided adhesive tape 5 Instruction Manual and Warranty Card 6 2 AAA 1 5V batteries 7 2 AAA 1 5V batteries ADDITIONAL EQUIPMENT 1 Philips screwdriver not included Figure 1 Figure 2 2 ...

Page 4: ...rature station 4 DO NOT PRESS ANY BUTTONS FOR 10 MINUTES In this time the indoor temperature station and remote temperature sensor will start to talk to each other and the display will show both the indoor and outdoor temperature If the indoor temperature station does not display both temperatures after the 10 minutes please retry the set up as stated above After both the indoor and outdoor temper...

Page 5: ...indoor temperature station after the 10 minutes have passed please follow the steps below 1 To set the time press and hold the SET button for 5 seconds Note A 12h or 24h will appear on the top line 12h for AM PM 24h for military time a To change between 12h and 24h press and release the MIN MAX button b When you have your choice shown on the display press and release the SET button once 2 Degrees ...

Page 6: ...ease the SET button once 4 The minutes will now be flashing a Press and release the MIN MAX button until the correct minutes are displayed Press and release the SET button once more to complete the setup DETAILED SETUP GUIDE I BATTERY INSTALLATION A REMOTE TEMPERATURE SENSOR 1 Remove the mounting bracket 2 Remove the battery cover 3 Observing the correct polarity install 2 AA batteries make sure t...

Page 7: ...emperatures to register incorrectly 1 Remove the battery cover on the backside To do this push the cover upward and pull it out 2 Observing the correct polarity install 2 AAA batteries 3 Replace the battery cover 4 Wait 10 minutes or until both the indoor and outdoor temperatures are shown on the indoor temperature station Battery Cover 6 ...

Page 8: ... and OUTDOOR LCD s II TIME A SETTING THE TIME 1 Press and hold the SET button for 5 seconds 12h will appear in the TIME LCD 2 Press and release the MIN MAX button to select either 12h time am pm or 24h time 3 Press and release the SET button 2 times the hour will flash in the upper left corner 7 ...

Page 9: ...a PM display which appears under TIME If there is no display then it is in AM mode Make sure you set the time accordingly III UNITS OF TEMPERATURE MEASURE A SELECTING UNITS OF MEASUREMENT 1 Press and hold the SET button for 5 seconds until 12h or 24h appears in the TIME LCD 2 Press and release the SET button again F will appear in the TIME LCD 3 Press and release the MIN MAX button to shift betwee...

Page 10: ...ill also flash B RESETTING THE MINIMUM AND MAXIMUM TEMPERATURES 1 To reset both the minimum and maximum temperatures press and hold the RESET button for 4 seconds V MOUNTING Note To achieve a true temperature reading avoid mounting in direct sunlight We recommend that you mount the remote temperature sensor on an outside North facing wall The sending range is 80 feet obstacles such as walls concre...

Page 11: ... to use the table stand all that is required is to place the indoor temperature station in an appropriate location 2 To wall mount remove the table stand To do this pull down on the stand from the rear and rotate forward a Fix a screw not included into the desired wall and place the indoor temperature station onto the screw using the hanging hole on the backside Gently pull the indoor temperature ...

Page 12: ...e sensor and indoor temperature station in position so the straight line signal is not passing through more than two or three walls Problem Temperatures do not match if units are placed next to each other Solution Each temperature sensor is manufactured to be accurate under normal conditions to within 1 degree plus or minus and so two temperature sensors could be as much as 2 degrees different How...

Page 13: ... harder to compare different ranges with different curves Under non laboratory conditions it is difficult to compensate for the above factors and obtain an accurate comparison MAINTENANCEAND CARE INSTRUCTIONS Extreme temperatures vibration and shock should be avoided to prevent damage to the units Clean displays and units with a soft damp cloth Do not use solvents or scouring agents they may scrat...

Page 14: ...or 0 2 F resolution 29 9 C to 69 0 C with 0 1 C resolution Temp accuracy 1 F 5 C Transmitting range Maximum 80 feet 25m open space Temperature check Indoor Every 10 seconds Outdoor Three times in 10 minutes Batteries Alkaline recommended Remote Temperature 2 x AA 1 5V Sensor Indoor Temperature 2 x AAA 1 5V Station Dimensions L x W x H Indoor Temperature 2 75 x 92 x 4 3 in Station excluding table s...

Page 15: ...ll remedy any such defects if they appear within one 1 year from date of purchase This warranty gives you specific legal rights and you may have other rights which vary from state to state FCC ID OMO 01RX Receiver OMO 01TX transmitter THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE 2 THIS DEVIC...

Page 16: ... 2002 Oreck Holdings LLC All rights reserved ...