INTRODUCTION

Congratulations on your purchase of the Weather forecaster with
cable free sensor and radio-controlled calendar clock (BAR113).

A multifunction device, this unit has a large four-line liquid
crystal display (LCD) for displaying weather forecast information,
in/outdoor temperatures, a radio frequency (RF) controlled calendar
clock, time zone adjusted time, and dual daily alarms. Also, it can
display temperature readings from up to three wireless remote
thermo-sensors.

Other features include a day-of-the-week display in four abbreviated
languages, a four-step crescendo alarm, and interchangeable clock
display modes.

MAIN FEATURES: MAIN UNIT

R E S E T

A L

° C

° F

O N /O F F

4 3 3 M H   C A B L E  F R E E

Z

C H A N N E L

M E M

M O D E   /   S ET

Summary of Contents for BAR113

Page 1: ...liquid crystal display LCD for displaying weather forecast information in outdoor temperatures a radio frequency RF controlled calendar clock time zone adjusted time and dual daily alarms Also it can display temperature readings from up to three wireless remote thermo sensors Otherfeaturesincludeaday of the weekdisplayinfourabbreviated languages a four step crescendo alarm and interchangeable cloc...

Page 2: ...arm times Current time and date in another time Zone Radio Frequency RF status indicator ALARM ON icon indicates when the alarm is active Alarm indicator B CONTROL BUTTONS B1 CHANNEL BUTTON Sets the remote sensor channel B2 MEM BUTTON Displays minimum and maximum temperature readings and erases memory data B3 ALARM BUTTON Displays the alarm time or changes the alarm set time B4 MODE SET BUTTON Cha...

Page 3: ...ote unit on a flat surface BEFORE YOU BEGIN For best operation Insert batteries for the remote unit first Then proceed with inserting the batteries for the main unit Position the remote unit and the main unit within effective transmission range In usual circumstances the effective range is 30 meters Though the remote unit is weather proof it should be placed away from direct sunlight rain or snow ...

Page 4: ...r and secure the screws Note Disposed of improperly batteries can be harmful Protect the environment by taking exhausted batteries to authorized disposal stations BATTERY INSTALLATION MAIN UNIT 1 Gently lift the tab on the battery compartment door 2 Insert four UM 3 or AA size alkaline batteries 3 Replace the battery compartment door Note For both the remote sensor and the main unit replace batter...

Page 5: ...URES The maximum and minimum recorded temperatures will be automatically stored in memory To display them press MEM Press MEM again to alternate between the maximum minimum and current temperatures The respective MAX or MIN indicator will be displayed To clear the memory press MEM button and hold for three seconds The maximum and minimum recorded temperatures will be erased Subsequently if you pre...

Page 6: ...l toggle the display in the above order Note The bottom line of the display will be replaced by the alarm time if the ALARM button is pressed ABOUT RADIO RECEPTION The BAR113 is designed to automatically synchronize its calendar clock once it is brought within range of the UK Rugby MSF 60 radio signal When the BAR113 is within range its radio control mechanism will override all manual settings Whe...

Page 7: ... to set the minutes current date month display language day of week and offset for the alternate time zone Note The time and date are displayed in 12 HOUR clock format For the language display you can choose among English E German D French F and Italian I Day of week is in the usual sequence of Monday through Sunday For the alternate time zone which is indicated by the ZONE icon enter the hour off...

Page 8: ...FF button Pressing or AL ON OFF will stop the alarm which is still armed and will activate at the set time the following day If AL ON OFF button is pressed again the alarm will be stopped and deactivated all together NOTE ON OUTDOOR REMOTE TEMPERATURE Once batteries are in place in the remote unit it will start transmitting samplings at 30 second intervals If no signals are received when the outdo...

Page 9: ...t lint free cloth 2 Do not clean the unit with abrasive or corrosive materials Abrasive cleaning agents may scratch the plastic parts and corrode the electronic circuit 3 Do not subject the unit to excessive force shock dust temperature or humidity Such treatment may result in malfunction a shorter electronic life span damaged batteries or distorted parts 4 Do not tamper with the unit s internal c...

Page 10: ...ange 5 0 C to 50 0 C 23 0 F to 122 0 F Temperature resolution 0 1 C 0 2 F Remoteunit Proposed operating range 20 0 C to 60 0 C 4 0 F to 140 0 F Temperature resolution 0 1 C 0 2 F RF Transmission Frequency 433 MHz RF Transmission Range Maximum 30 meters Temperature sensing cycle around 30 seconds Power Main unit use four 4 UM 3 or AA 1 5V alkaline battery Remote sensing unit use two 2 UM 4 or AAA 1...

Page 11: ...00 220 1 2 3 1997 Electromagnetic compatibility Article3 1 boftheR TTEDirective applied standard s ETS 300 683 1997 Safety of information technology equipment Article 3 1 a of the R TTE directive applied standard s EN 60950 1997 Additional information The product is therefore conform with the Low Voltage Directive 73 23 EC the EMC Directive 89 336 EC and R TTE Directive 1999 5 EC appendix II and c...