background image

INTRODUCTION

Thank you for purchasing the RCC Clock . Please read carefully through the following

 information and keep these instructions, in case you need to refer to them in the future.  If you 

pass the product on to someone else, please also include these instructions.

The Radio-Controlled  Clock (RCC Clock) displays:

- indoor temperature

- date / time / weekday 

- alarm

The RCC Clock is unsuitable for commercial use in weather forecasting or in temperature data 

measurement.

PACKAGE CONTENTS

Main unit

   AAA batteries

 for main unit x 2

OVERVIEW

1

          Press to activate the snooze functon,backlight .  

2

:     

In Date mode, press to turn on/off zone. In Alarm time 

     mode, press to turn on/off alarm. Press and hold to enter time 

     and date setting.

3

:  

 Press to show alarm time of Alarm 1-5 and Alarm 6-7. 

     Press and hold to enter alarm setting.

4

:  

   Press to switch between Temperature and Week Day

     display. Press and hold to start RCC signal receiving. In 

     setting mode, press to increase one unit, press and hold 

     to increase rapidly.

5:     Press to switch between Date and the nearest coming 

    Alarm time.In setting mode, press to decrease one unit, 

   press and hold to decrease rapidly.

6

Battery compartment. Slide down to open.

LCD DISPLAY

1: Time Display

2: Date display or Alarm time display

3: Temperature display or Week Day display

RCC signal received
Alarm ON
DST ON
Snooze Activated
Low battery indicator
Temperature mode

GETTING STARTED

INSERT BATTERIES

1: Remove the battery door from the back

2: Insert 2 R03 (AAA)/ 1.5V batteries. Please ensure the polarities (+/-) of the batteries 

    match upon installation.

3: Reattach the battery door.

NOTE

: Replace batteries when     displays, or when the display is dim.

CLOCK

CLOCK RECEPTION  

1: Replace batteries or press         button will initiate RCC receiving.

2: RCC receiving can be worked in both Date Mode and Alarm Mode.

3: The receiving process duration is 7 minutes.

4: During receiving process, the RCC signal logo       flashes.

5: During receiving process, press          button to quit receiving, press other buttons 

   can work normally.

6: If process is successful, completed RCC logo       will be shown in display. If it fails within 

    7 minutes, RCC setting will be quit automatically.

7: RCC receiving will automatically start at 2:03, 3:03, 4:03 , 5:03 every night. Auto 

    receiving function will cease if it is successful.

Front

back

ALARM

SETTING/ADJUSTING ALARM TIME

1. Press and hold       button, enter alarm setting

2. Sequence of setting: weekday hour 

    

 weekday minute 

    

 weekend hour 

    

 weekend  

    minute 

    

 exit

3. During setting, the setting parameter will flash.

4. Press      button to confirm setting and enter to next parameter

5. Press         button once, the figure will increase 1 unit. Press and hold the         button, the figures  

    will increase rapidly.

6. Press         button once, the figure will decrease 1 unit. Press and hold the         button, the  

    figures will decrease rapidly.

7. Press         button to turn on/off alarm

8. Alarm will automatic turn on when alarm setting finish.

9. If there is no action in 20 seconds, the setting will be saved and will exit the setting mode.

TURN ON/OFF ALARM

1. When it is displaying the nearest coming Alarm time, press          button once to turn on/off that 

    alarm. (1-5) or (6-7) will flash to indicate which alarm displaying.

2. Press      button once to switch to alarm mode. Monday to Friday alarm time will be shown and  

    (1-5) will flash.

3. Press         button once to turn on/off Monday to Friday alarm

4. Press      button again to show Saturday to Sunday alarm time. (6-7) will flash.

5. Press         button once to turn on/off Saturday to Sunday alarm. 

OPERATION

1. At the set time, alarm signal rings. 

2. During alarm rings, press any keys to end the alarm. Or press          button to delay the alarm for  

    8 minutes.

3. If do not press any button to end the alarm, it will turn off automatically after 5 minutes.

4. Alarm will be start again at next alarm time, unless switch off the alarm function in alarm mode.

PRECAUTIONS

Hazards for children

    

Batteries can be life-endangering if swallowed. Please keep the RCC Clock and batteries 

       out of reach of children. If a battery has been swallowed, please seek medical assistance 

       immediately.

    

Keep children away from packaging material and the small parts in the scope of delivery. 

       Suffocation hazard if swallowed. 

I

njury hazard

   

 Caution: Explosion hazard with improper handling of batteries. Batteries must not be charged, 

       reactivated with other means, dismantled, thrown into fire or short-circuited.

    

Avoid contact with skin, eyes and mucous membranes. When coming into contact with battery 

       acid, immediately rinse the affected areas with plenty of clear water and immediately contact a 

       physician.

Caution – property damage

    

Protect the RCC Clock from dust, impact, extreme temperatures and direct sunshine. Also 

       protect the RCC Clock from moisture. Exclusively position Projection Clock in a dry, 

       enclosed space.

    

Remove the batteries from the RCC Clock, if they become depleted or if you are not using 

       the RCC Clock for a longer period of time.

Different model receives different RCC signal:
     

          Region                       Signal

      

          EU 

                      DCF

      

          UK 

                      MSF

SET THE CLOCK MANUALLY

1. Press and hold           button, enter time and date setting

2. Sequence of setting: Week Day Language 

    

12/24 Hr 

   

 Year (2000 – 2099) 

   

 Date format

 

      

Month 

    

Date 

    

Hour        Minute 

   

 Zone 

    

 

/

       exit

3. During setting, the setting parameter will flash.

4. Press         button to confirm setting and enter to next parameter

5. Press         button once, the figure will increase 1 unit (when setting minute, second will reset to  

    0). Press and hold the         button, the figures will increase rapidly.

6. Press     button once, the figure will decrease 1 unit (when setting minute, second will reset to 

    0). Press and hold the      button, the figures will decrease rapidly. 

7.If there is no action in 20 seconds, the setting will be saved and will exit the setting mode.

Five languages Week Day display: GER, ENG, FRE, ITA, DUT.

 

                Symbol     Monday    Tuesday    Wednesday    Thursday    Friday    Saturday    Sunday

German         GER         MON          DIE              MIT             DON         FRE 

SAM          SON

English 

 ENG        MON          TUE            WED             THU         FRI 

 SAT          SUN

France 

 FRE         LUN           MAR           MER             JEU        VEN 

 SAM         DIM

Italian 

 ITA           LUN           MAR           MER             GIO        VEN 

 SAB         DOM

Dutch 

DUT         MAA            DIN            WOE             DON         VRI 

  ZAI          ZON

 

 

   

Do not expose the batteries to any extreme conditions by e.g. placing them on a radiator or 

       under direct sunlight.

    

Clean the battery and appliance contacts prior to insertion, if required.

    

Using same type of batteries. Do not use different types or used and new batteries together.

    

Do not carry out any changes to the device. Only allow repairs to be carried out by a 

       professional workshop. 

    

Never use hard, scratching or abrasive detergents or similar, for cleaning the RCC Clock. 

       This could scratch the surfaces.

SPECIFICATIONS

L x W x H                                           72 x 25 x 75 mm
Weight (Main unit) 

                   73g (Exclude batteries)

Temperature display range                  -10

 to +50

 (14

 to 122

)

Accuracy                                           0

 to +40

: +/- 1.5

 (+/-3

)

                                                            <0

 and >+40

: +/- 2

 (+/-4

)

   Resolution                                          0.1

 (0.2

)

   Power 

                                        2 x R03 (AAA) 1.5V batteries

                                                             

NOTE:

 

    

When the temperature is lower than -10

(14

), the temperature displays LL.L. When the 

temperature is higher than 50

(122

), the temperature displays HH.H.

    

During alarm rings or RCC receiving process, temperature detection will be stopped.

NOTE:

 The technical specifications for this product and the contents of the user manual are subject 

to change without notice.

EU-DECLARATION OF CONFORMITY

Disposal:

             Guideline 2012/19/EC concerning the handling, collection, recycling and disposal of     

             electrical and electronic equipment and their components (‘waste electrical and electronic  

             equipment’, known as WEEE). 

The crossed symbol on a rubbish container indicates that the machine or device is not allowed to be 

disposed of but it must be handed over to a suitably equipped collection centre for proper recycling 

or disposal.

Directives:

             We declare that this device has been manufactured in accordance with the applicable rules  

             and regulations.

Summary of Contents for RM511

Page 1: ...e RCC receiving 2 RCC receiving can be worked in both Date Mode and Alarm Mode 3 The receiving process duration is 7 minutes 4 During receiving process the RCC signal logo flashes 5 During receiving process press button to quit receiving press other buttons can work normally 6 If process is successful completed RCC logo will be shown in display If it fails within 7 minutes RCC setting will be quit...

Page 2: ... circuited Avoid contact with skin eyes and mucous membranes When coming into contact with battery acid immediately rinse the affected areas with plenty of clear water and immediately contact a physician Caution property damage Protect the RCC Clock from dust impact extreme temperatures and direct sunshine Also protect the RCC Clock from moisture Exclusively position Projection Clock in a dry encl...

Page 3: ...gang dauert 7 Minuten 4 Während des Empfangs blinkt das Funksignal Symbol 5 Der laufende Empfangsvorgang kann durch Drücken der Taste abgebrochen werden Alle anderen Tasten funktionieren auch während des Empfangsvorgangs wie gewohnt 6 Nach dem erfolgreichen Abschluss des Funksignalempfangs wird das Symbol auf dem Display angezeigt Wenn der Empfangsvorgang nicht innerhalb von 7 Minuten abgeschlosse...

Page 4: ...efahr Batterien dürfen nicht aufgeladen anderweitig reaktiviert zerlegt ins Feuer geworfen oder kurzgeschlossen werden Vermeiden Sie Kontakt mit der Haut den Augen und Schleimhäuten Bei Berührung von Batteriesäure die betroffenen Bereiche sofort gründlich mit frischem Wasser abspülen und sofort einen Arzt konsultieren Vorsicht Sachschäden Schützen Sie die Funkuhr vor Staub Aufprall extremen Temper...

Page 5: ... s affiche ou lorsque l écran est sombre HORLOGE RÉCEPTION DE L HORLOGE 1 Remplacez les piles ou appuyez sur la touche pour lancer la réception du signal de pilotage radio 2 La réception du signal peut se faire en mode de date et d alarme 3 La durée du processus de réception est de 7 minutes 4 Au cours du processus de réception le logo du signal clignote 5 Au cours du processus de réception appuye...

Page 6: ...des piles Les piles ne doivent pas être chargées réactivées par d autres moyens démantelées jetées au feu ou court circuitées Éviter tout contact avec la peau les yeux et les muqueuses En cas de contact avec l acide des piles rincer immédiatement les zones touchées avec beaucoup d eau claire et consulter immédiatement un médecin Attention dommages matériels Protéger l horloge pilotée de la poussiè...

Page 7: ...cepción RCC 2 Puede usarse tanto en modo de fecha como en modo de alarma 3 La duración máxima del proceso de recepción es de 7 minutos 4 Durante el proceso el icono de la señal RCC parpadeará 5 Durante el proceso pulse el botón para salir del modo de recepción el resto de los botones funcionará de la manera habitual 6 Si el proceso tiene éxito aparecerá el icono de RCC completado en la pantalla Si...

Page 8: ...otro modo desmantele coloque sobre una llama ni cortocircuite las pilas Evite el contacto con la piel los ojos y las membranas mucosas Si alguna parte del cuerpo entra en contacto con el ácido que contienen las pilas aclare de inmediato las zonas afectadas con agua y póngase en contacto con un médico Precaución daños al dispositivo Proteja el reloj RCC del polvo los golpes las temperaturas extrema...

Page 9: ...erie o premere il pulsante per iniziare la ricezione RCC 2 La ricezione RCC si attiva 3 La durata del processo di ricezione è di 7 minuti 4 Durante il processo di ricezione il simbolo del segnale RCC lampeggia 5 Per disattivare o riattivare la ricezione RCC premere il pulsante 6 Se il processo viene eseguito correttamente il simbolo di RCC completato viene visualizzato sul display Se non viene com...

Page 10: ... Pericolo di soffocamento in caso di ingestione Pericolo di lesioni Attenzione pericolo di esplosione in caso di gestione errata delle batterie Le batterie non devono essere caricate o riattivate con altri mezzi smontate o gettate nel fuoco o messe in cortocircuito Evitare il contatto con la pelle con gli occhi e con le mucose Quando si entra in contatto con l acido della batteria risciacquare imm...

Page 11: ... The receiving process duration is 7 minutes 4 During receiving process the RCC signal logo flashes 5 During receiving process press button to quit receiving press other buttons can work normally 6 If process is successful completed RCC logo will be shown in display If it fails within 7 minutes RCC setting will quit automatically 7 RCC receiving will automatically start at 2 03 3 03 4 03 5 03 ever...

Page 12: ...d Caution Explosion hazard with improper handling of batteries Batteries must not be charged reactivated with other means dismantled thrown into fire or short circuited Avoid contact with skin eyes and mucous membranes When coming into contact with battery acid immediately rinse the affected areas with plenty of clear water and immediately contact a physician Caution property damage Protect the RC...

Reviews: