Induction Motors and Reversible Motors

 

   

   

   

 
 

 

Thank you for purchasing an Oriental Motor product. 

This Operating Manual describes product handling procedures and safety 

precautions. 

Please read it thoroughly to ensure safe operation. 

Always keep the manual where it is readily available. 

Before using the motor 

 

Introduction 

Only qualified personnel should work with the product. 

Use the product correctly after thoroughly reading the section “Safety 

precautions”. 

Should you require the inspection or repair of internal parts, contact the 

Oriental Motor office where you purchased the product. 

The product described in this manual has been designed and manufactured 

for use in general industrial machinery, and must not be used for any other 

purpose. Oriental Motor Co., Ltd. is not responsible for any damage 

caused through failure to observe this warning. 

 

Standard and CE marking 

Motors (except for 

5IK90GU-SWT

5IK90A-SWT

5IK150A-TWT

) are 

recognized by UL and certified by VDE. 

Recognized name and certified name are motor model name. 

The certificate by VDE is valid only for the motor assembly itself. The 

capacitor is not included in the certificate. 

However, both the motor assembly and capacitor combined have been 

tested against and have passed EN 60950-1 Annex B.8. 

5IK90GU-SWT

 and 

5IK90A-SWT

 are recognized by UL and certified by 

DEMKO. 

Voluntary display of the CE mark conforming to the Low Voltage 

Directives. 

 

Standards 

UL 1004-1, UL 1004-2, UL 1004-3 

CSA C22.2 No.100, CSA C22.2 No.77, EN 60950-1 

Standards File No. 

UL File No. E64199 (6 W type), E64197 (25 to 150 W type),   

VDE, DEMKO 

 

Applications for standard 

EN 60034-1, EN 60034-5, EN 60664-1, EN 60950-1 

 

A Running Heating Test and a Locked-Rotor Test has been conducted 

with a aluminum radiation plate of size indicated below. For the motor 

with a gear head, tests has been conducted with a gear head instead of the 

radiation plate. 

 

First number in 

motor name 

Size [mm (in.)] 

Thickness 

[mm (in.)] 

Material 

115 × 115 (4.53 × 4.53) 

135 × 135 (5.31 × 5.31) 

5 (40 W) 

165 × 165 (6.50 × 6.50) 

5 (60 W, 90W, 

150 W) 

200 × 200 (7.87 × 7.87) 

5 (0.20) 

Aluminium

 

Installation conditions 

Overvoltage category II, Pollution degree 2, Class I equipment (For EN 

standards) 

When the machinery to which the motor is mounted requires overvoltage 

category III and pollution degree 3 specifications, install the motor in a 

cabinet that comply with IP54 and connect to power supply via an 

isolation transformer. 

 

Standards for accessories 

Capacitor :  UL File No. E83671 (CYWT2), VDE License No. 114747 

(for only capacitor rated voltage 450 VAC types) 

Capacitor cap : UL File No. E56078 (YDTU2) 

 

Electrical appliance and material safety law 

The three-phase round shaft motor type bears a 

 mark. 

Safety precautions 

The precautions described below are intended to prevent danger or injury 

to the user and other personnel through safe, correct use of the product. 

Use the product only after carefully reading and fully understanding these 

instructions. 

 

Handling the product without observing the instructions 

that accompany a “Warning” symbol may result in 

serious injury or death. 

Handling the product without observing the instructions 

that accompany a “Caution” symbol may result in injury 

or property damage. 

Note 

The items under this heading contain important handling 

instructions that the user should observe to ensure safe 

use of the product. 

 

 

• 

Do not use the product in explosive or corrosive environments, in 
the presence of flammable gases, locations subjected to 
splashing water, or near combustibles. Doing so may result in fire, 
electric shock or injury. 

• 

Assign qualified personnel the task of installing, wiring, operating/ 
controlling, inspecting and troubleshooting the product. Failure to 
do so may result in fire, electric shock or injury. 

• 

Do not transport, install the product, perform connections or 
inspections when the power is on. Always turn the power off 
before carrying out these operations. Failure to do so may result 
in electric shock. 

• 

Turn off the power in the event the overheat protection device 
(thermal protector) is triggered. Failure to do so may result in 
injury or damage to equipment, since the motor will start abruptly 
when the overheat protection device (thermal protector) is 
automatically reset. 

• 

The motor is Class 

I

 equipment. Install the motor so as to avoid 

contact with hands, or ground it to prevent the risk of electric 
shock. If the motor has a protective ground terminal, be sure to 
connect the terminal to the ground.

 

Dieser Motor ist in Geräten mit Schutzklasse I zu verwenden. Der 

Motor ist so einzusetzen, dass er nicht berührt werden kann, bzw. er ist 

zu erden, um Stromschläge zu verhindern. Wenn der Motor über eine 

Schutzerdungsklemme verfügt, ist die Erdung über diese vorzunehmen. 

• 

Install the motor in an enclosures in order to prevent electric 
shock or injury. 

• 

Keep the input-power voltage within the specification to avoid fire 
and electric shock. 

• 

Connect the cables securely according to the wiring diagram in 
order to prevent fire and electric shock. 

• 

Do not forcibly bend, pull or pinch the lead wires. Doing so may 
result in fire and electric shock. 

• 

Be sure to insulate the connection terminal of the capacitor. 
Failure to do so may result in electric shock. 

• 

Turn off the power in the event of a power failure, or the motor 
will suddenly start when the power is restored and may cause 
injury or damage to equipment. 

Summary of Contents for 2IK6GN-AWTJ

Page 1: ...citor cap UL File No E56078 YDTU2 Electrical appliance and material safety law The three phase round shaft motor type bears a mark Safety precautions The precautions described below are intended to prevent danger or injury to the user and other personnel through safe correct use of the product Use the product only after carefully reading and fully understanding these instructions Handling the prod...

Page 2: ...60GU AWT CH180CFAUL 5IK60GU CWTJ 5IK60GU CWT CH50BFAUL 5IK60GU CWTE 5IK60GU CWT CH40BFAUL 5IK90GU AWTJ 5IK90GU AWT CH280CFAUL 5IK90GU AWTU 5IK90GU AWT CH200CFAUL 5IK90GU CWTJ 5IK90GU CWT CH70BFAUL 5IK90GU CWTE 5IK90GU CWT CH60BFAUL 2IK6GN SWT 2IK6GN SWT 4IK25GN SWT 4IK25GN SWT 5IK40GN SWT 5IK40GN SWT Model Motor model Capacitor model 5IK60GU SWT 5IK60GU SWT 5IK90GU SWT 5IK90GU SWT 5IK150A TWT 5IK1...

Page 3: ...ction Note Insulation class of this motor is B Make sure that the motor case temperature does not exceed 90 C 194 F during operation of the motor Operation exceeding case temperature 90 C 194 F may significantly deteriorate the coils and ball bearings of the motor and shorten the motor s life span Motor case temperature can be measured by fixing a thermometer on the motor surface It can also be me...

Page 4: ...ble to determine the appropriate tightening torque to use when fastening the terminal box cover and cable outlet Tightening torque Terminal Box Cover 0 3 to 0 4 N m 42 to 56 oz in Cable Outlet of Terminal Box Cover 2 5 to 3 8 N m 350 to 530 oz in Cable Clamp 0 2 to 0 3 N m 28 to 42 oz in Motor Connecting Terminals 0 5 to 0 8 N m 71 to 113 oz in Note To make shielding function fully effective use a...

Page 5: ...Power is turned off at 130 5 C 266 9 F Power is turned back on at 82 15 C 180 27 F Impedance protection ZP is stamped on the motor nameplate The motor has higher coil impedance When the motor goes into locked rotor condition due to a malfunction coil impedance rises suppressing input power to the motor and protecting the motor coil from burnout Troubleshooting When the motor cannot be operated cor...

Page 6: ... November 2019 Technical Support Tel 800 468 3982 8 30 A M to 5 00 P M P S T M F 7 30 A M to 5 00 P M C S T M F www orientalmotor com Schiessstraße 44 40549 Düsseldorf Germany Technical Support Tel 00 800 22 55 66 22 www orientalmotor de Tel 01256 347090 www oriental motor co uk Tel 01 47 86 97 50 www orientalmotor fr Tel 02 93906346 www orientalmotor it Tel 55 11 3266 6018 www orientalmotor com b...