background image

   

   

   

Operating   Manual   

-­‐-­‐CN90B   Industrial   Coil   Nailer-­‐-­‐   

   

   

   

   

   

   

   

   

   

   
   

  

 

NOTE: Please read and fully understand the instructions in this 
manual

   

before operating the pneumatic power tool. Carefully read 

through

   

this OPERATOR'S MANUAL to ensure efficient, safe 

operation. It is

   

recommended that the Manual be kept readily available 

as an important

   

reference when using this tool. 

      

 
 

 

Summary of Contents for CN90B

Page 1: ...y understand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manual be kept readily available as an important reference when using this tool ...

Page 2: ...ailers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing appropriate safety procedures Basic safety precautions are outlined in the SAFETY section of this manual and in the sections which contain the operation and maintenance instructions Hazards that must be avo...

Page 3: ...essional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident prevention regulations directives and generally recognized technical regulations e g CEN and CENELEC standards to be able to assess the safe working condition of fastener driving tools g Stands for mounting ...

Page 4: ...evels which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER SOURCE EXCEPT AN AIR COMPRESSOR The tool is designed to operate on compressed air Do not operate the tool on any other high pressure gas combustible gases e g Oxygen acetylene etc since there is the ...

Page 5: ...Whenever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and this and similar actions should be avoided 10 NEVER POINT THE DISCHARGE OUTLET TOWARD YOURSELF AND PERSONNEL If the discharge outlet is pointed toward people serious accidents may be caused when mis...

Page 6: ...r may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at the lower part and gradually work your way up Fastening backward is dangerous as you may lose your foot place Secure the hose at a point close to the area you are going to driver fasteners Accidents...

Page 7: ...ion mode Contact actuation Magazine capacity 200 300 nails Maximum allowable pressure 120psi 8 3bar Recommended pressure range 70psi to 100psi 5bar to 7bar Fasteners Only the nail sizes shown in the table below can be driven with this nailer 15 Wire welded coil nails Applications Floor and wall framing Roof and wall sheathing Fencing Making pallets drums and wooden boxes ...

Page 8: ...ply compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The female coupler will connect to the quick release that fits the tool 2 Filter Regulator Lubricator NEVER connect nailer to pressure which potentially exceeds 120psi Filter regulator lubricator units supply...

Page 9: ... wood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air filter will help to get the best performance and minimum wear from the tool Frequent but not excessive lubrication is required for the best performance Oil added through the air line connection will l...

Page 10: ...itting the hands or body by mistake Nail loading 1 Disconnect the air hose 2 Press LATCH 210470 to open DOOR 211560 then open MAGAZINE COVER 422090 3 Adjust the height of NAIL SUPPORT 422100 according to nails length 4 Fix the first nail in the groove on FEED PAWL 211570 5 Close MAGAZINE COVER 422090 close DOOR 211560 6 Connect the air hose Test operation 1 Adjust the air pressure at 70psi 5 bar a...

Page 11: ...the nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In case of frequent jams contact an authorized service center A qualified person should perform repair and maintenance Periodic maintenance to be performed Check that the piston bumper is operating norma...

Page 12: ...LASTIC WASHER 85 211570 FEED PAWL 29 320610 HEAD VALVE WASHER 86 621580 FEED PAWL SPRING A 30 420580 TRIGGER 87 621590 FEED PAWL SPRING B 31 110190 TRIGGER ADJUSTER BUTTOM 88 510320 O RING 10X2 65 32 323220 DOWEL PIN 89 320210 FEED PAWL PIN 33 420590 TRIGGER BRACKET 90 324800 FEED PISTON 34 620370 ADJUSTER SPRING 91 510430 O RING 20X2 65 35 320880 CONTACT PLATE 92 621600 FEED PISTON SPRING B 36 62...

Page 13: ... TOOL SCHEMATIC CN90B ...

Page 14: ... CN90B Industrial Coil Nailer 1511 ...

Reviews: