background image

 

 

Ortal Installation Manual: Heat Control System (V1) 

Installation and Operation Manual 

Heat Control System

® 

 

 

 

 

Summary of Contents for Heat Control System

Page 1: ...Ortal Installation Manual Heat Control System V1 Installation and Operation Manual Heat Control System ...

Page 2: ...the responsibility of Ortal WARNING HEAT BARRIER A barrier designed to reduce the risk of burns from hot viewing glass is provided with this fireplace and shall be installed The fireplace MUST not be used without the heat barrier in place If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this fireplace Any safety screen guard or barrier removed for se...

Page 3: ...________________ 8 Prior to Installation 8 Installation Procedure 9 System Setup 13 Air Ducting _________________________________________________________________________ 16 Duct Requirements 16 Duct Termination 16 Electrical___________________________________________________________________________ 16 Electrical Requirements 16 Wiring Diagrams 16 Operation _________________________________________...

Page 4: ...xtracts heat from the chase via two heat collector boxes and ducts it to the chosen location see figure 2 below Figure 2 Heat Control System is On When the system is off the heat is directed into the room via the heat release see figure 3 below Figure 3 Heat Control System is Off This feature is optional and is not required for the use and operation of any Ortal manufactured fireplace It is approv...

Page 5: ...and Curve Island 130 75x65 Curve 75x65 Curve TN Units that are framed into a wall only without a hood NOTE The Heat Control System cannot be used with Ortal 40H70 models 60x80 models stand alone Curves and Island or wall mounted Stand Alone fireplaces This system designed for use with Ortal manufactured fireplaces only It is not permitted for use with fireplaces made by other manufacturers or for ...

Page 6: ...ndard Fan Max Flow Rate 196 CFM Noise Level 56 dba at 1 meter from fan Dimensions Clearances NOTE 2 inch clearance is to any building material No additional air space is required beyond the 2 inch clearance ...

Page 7: ...OTE When determining installation location take note that the duct connections on the fan are set on a 90 angle See Premium Fan Airflow Direction section for details Clearances NOTE 2 inch clearance is to any building material No additional air space is required beyond the 2 inch clearance ...

Page 8: ...lace Optimal duct length is 90 feet or less Total duct length must not exceed 120 feet The Heat Control System must be installed in an interior space and can terminate either to an interior or exterior space NOTES The system is designed to remove heat from the chase and has no impact on radiant heat released from the fireplace glass Depending on local code make up air may need to be supplied to th...

Page 9: ...4 Position and connect T Connector to Insulated Air Ducting using a minimum of 3 self tapping screws per connection 5 Connect Insulated Air Ducting to the Heat Control Fan using one Hose Clamp per connection 6 Position and secure Heat Collector Boxes to the front wall inside the fireplace chase using a minimum of 4 screws per box 7 Connect Insulated Air Ducting to each Heat Collector Box using a m...

Page 10: ... or narrow side of the fan a Place the fan on a flat concrete wood surface or wood studs Position it according to air flow direction Air Flow Direction NOTE Fan can be installed oriented horizontally or vertically Step 2 Attach the fan to a mounting area via the mounting brackets Securely fasten fan to the surface with 6 screws in provided holes 3 on each side as shown in figure below ...

Page 11: ...n s inlet and outlet pipe connections when determining installation location The duct connections are set 90 to each other The air inlet connection is on the wide side of the fan and the air outlet is on the narrow side Step 1 Connect the mounting brackets to the fan The brackets can be attached on either the wide option 1 or narrow option 2 side of the fan Wide Orientation Attach brackets to the ...

Page 12: ...e fan to attach brackets as shown in figure below Step 2 Affix the fan to a mounting area via the mounting brackets Mounting area must be constructed to support the weight of the fan 52 lbs 23 5 kg Installation requires ten screws with 10mm diameter not included Wide Orientation Narrow Orientation ...

Page 13: ... note that the distances in these diagrams are exact measurements and are not maximums or minimums For example the top of the heat collectors should be located exactly 4 inches below the bottom of the heat release Frame the fireplace chase to the minimum framing values as stated in the applicable Ortal fireplace installation manual NOTE The bullet pointed statements above are recommendations and a...

Page 14: ...14 Series 110 130 Wilderness 44H Wilderness TR42 Traditional 90 110 ...

Page 15: ...15 Series 150 170 Series 200 250 ...

Page 16: ...ter must allow for minimum 28 square inches of net free air space Clearances No clearance requirements Check with local code for approved components and clearances if any Electrical WARNINGS Electrical connections should be completed by a certified electrician and in accordance with local building codes Disconnect the power supply before servicing any electrical components Electrical Requirements ...

Page 17: ...17 Wiring Diagram Screen Fireplace Wiring Diagram Screen Fireplace with Interior Lighting and Ortal Power Vent ...

Page 18: ...18 Wiring Diagram Double Glass Fireplace ...

Page 19: ...System is designed to operate in sync with the Ortal fireplace To operate the fireplace and Heat Control System together ensure the Heat Control System wall switch is in the on position Turn the fireplace on The system will turn on and off with the fireplace The wall switch should remain in the on position to keep the system s connection to the fireplace open To operate the fireplace without the H...

Page 20: ... Ortal 2020 Version 1 December 2020 SKU KPMANUALHSUS Ortal USA 8421 Canoga Ave Canoga Park CA 91304 T 818 238 7000 F 818 678 0541 info ortalheat com www ortalheat com ...

Reviews: