background image

 

 

 

 

 

Operating Manual 

 

 

ORTNER ST11 42/59

 

Manual and automatic operation 

 

Before the commissioning of the firing installation, the operating manual must be 

read; 

disregard of the instructions will lead to the voiding of the manufacturer’s 

warranty. 

 

The respective national or local regulations and general provisions and codes of 

practice must be complied with! 

 

Do NOT use this firing installation as a waste incinerator. 

 

 

Version: 10_2016 

Summary of Contents for ST11 42/59

Page 1: ...lation the operating manual must be read disregard of the instructions will lead to the voiding of the manufacturer s warranty The respective national or local regulations and general provisions and codes of practice must be complied with Do NOT use this firing installation as a waste incinerator Version 10_2016 ...

Page 2: ...1 ORTNER GmbH Hürmer Straße 36 in A 3382 Loosdorf Tel 43 2754 2707 Fax 43 2754 2708 office ortner cc at www ortner cc at ...

Page 3: ...ng substances 6 Special instructions 7 Commissioning 7 Caution 7 Note 7 Cleaning and maintenance 8 Caution 8 Troubleshooting 9 The draught of the stove is insufficient the fire almost goes out Caution Risk of deflagration 9 Flue gas leakage from the stove 9 The stove does not become sufficiently warm 9 Condensate escapes from the stove pipe and the chimney becomes wet and sooty 9 The wood does not...

Page 4: ... the stove can only be ensured under adherence of all requirements specified in the operating manual The ST11 42 59 has been verified in accordance with EN13229 and additionally complies with the following national emissions requirements CO mg MY NOx mg MY OGC mg MY Dust mg MY Austria 15a Environmental label UZ 37 1100 700 150 120 50 50 35 30 80 80 Germany BIMSchV 2nd stage 2015 830 27 70 80 Switz...

Page 5: ...purposes Racks for the drying of clothing must be positioned at a sufficient distance from the heating unit The handling of highly combustible or explosive substances is prohibited during the operation of the stove Remove the ash in the combustion chamber in a timely manner in order to prevent the blocking of the inlet air openings Before each lighting ensure both an unimpeded sufficient inlet air...

Page 6: ... the wood can be ignited In order to prevent the release of heating gas the firebox door must always be closed except during lighting when refilling with fuel and during ash removal In order to refill fuel the door may only be opened after the wood has been burnt shortly before the embers phase Control elements and their function in automatic operation The dual pane glass door is opened or closed ...

Page 7: ...posits pitch like deposit on the inside of the pane on the ceramic components as well as the chimney risk of a chimney fire Wood will only achieve an optimal heating value when it has been stored dry and ventilated under a roof for at least two years The logs should have an equal length and have a weight of 1 2 kg In regard to the length pay attention that the wood fits correctly in the combustion...

Page 8: ... overloading This will create sharp parts CAUTION RISK OF INJURY Commissioning Remove all documents and accessory parts present in the firebox Press the operating lever fully into the open position Stack up 11 kg hardwood logs with a length of approx 33 cm corresponds to about 3 4 of the combustion chamber height Add finely chopped softwood on top and ignite this using firelighters lighting wool b...

Page 9: ...ed in cold condition Have the cleaning of the chimney the connection piece between the chimney and the firing installation and the ceramic components of the masonry heater performed regularly by a licensed specialist in accordance with the country specific regulations A blockage of the chimney may occur as a result of a prolonged interruption of the operation Therefore before each start up verify ...

Page 10: ...ey or an insufficient draught is present due to a higher outside temperature during the transition period If necessary install wind protection on the chimney The stove does not become sufficiently warm Check the wood s moisture content Condensate escapes from the stove pipe and the chimney becomes wet and sooty Possible causes are exhaust gas temperatures or chimney temperatures that are too low I...

Page 11: ...10 ORTNER GmbH Hürmer Straße 36 in A 3382 Loosdorf Tel 43 2754 2707 Fax 43 2754 2708 office ortner cc at www ortner cc at ...

Reviews: