OSCG Co., Ltd. Tel : +82 51 305 3910 Fax : +82 51 305 3933 Website: www.oscg.net
Address : #1242, Nakdongdaero, Sasang-Gu, Busan, Korea
1 / 2
Manual for OSER-Z Cable Gland
1. Application
OSER-Z Cable is for Any type of armoured cable gland(touch) for earthing for Zone 1 & Zone 2 in hazardous area.
2. Standard Applicable
3. Certificate No. & Special conditon 'X'
A. IECEx : IECEx PRE 17.0060X
B. ATEX : Presafe 17 ATEX 11324X
C. CU-TR : RU C-KR.AA87.B.01105
D. Special condition 'X' : Ambient temperature(-60
℃
~ +130
℃
) - IEC 60079-0 5.1.1
E. Compliance Standard : EN/IEC 60079-0/7/31, EN/IEC 61241-0/1, EN/IEC 60529
4. Technical data
A. Process control system : ISO 9001 : 2008, ISO 14001 - 2004 , RoHs
B. Certification : IECEx, ATEX, CU-TR
C. Marking
D. Suitable for use in Zone 1, Zone 2, Zone 21 & Zone 22
E. Suitable for use in gas Groups
Ⅱ
A,
Ⅱ
B and
Ⅱ
C, dust Groups
Ⅲ
A,
Ⅲ
B and
Ⅲ
C
F. Service Temperature: -60C
˚
~ +130C
˚
G. Ingress protection: IP66/68-20bar/2H (IEC 60529 / EN 60529)
H. Accessories : Sealing Washer
I. Materials: Brass C3604 BE-F(CuZn38Pb4) / Brass C3604 BE-F with Nickel Plated
5. Cable Specification for OSER-Z
ATEX
IECEx
EN 60079-0:2012+A11:2013
IEC 60079-0:2011 Ed. 6
EN 60079-7:2015
IEC 60079-7:2015 Ed. 5
EN 60079-15:2010
IEC 60079-15:2010 Ed. 4
EN 60079-31:2014
IEC 60079-31:2013 Ed. 2