background image

OPERATING MANUAL

SUB 118 SP

Self-powered sub-bass system

Summary of Contents for SUB 118 SP

Page 1: ...OPERATING MANUAL SUB 118 SP Self powered sub bass system ...

Page 2: ...1 1 DISPOSAL OF WASTE MATERIALS 3 1 2 CONFORMITY AND WARRANTY 3 2 DESCRIPTION OF THE SYSTEM 4 3 WIRING 5 3 1 CONNECTORS SPECIFICATIONS 5 3 2 CABLES AND PICTURES 6 4 AMPLIFICATION 7 4 1 DSP AND CONTROL THROUGH PC 8 5 PRESETS AND USES 11 5 1 SUB CARDIO PRESET CONFIGURATION 12 6 PERIODIC CONTROLS 14 6 1 PERIODIC IN DEPTH CHECKS 14 7 RICAMBI 15 8 SPECIFICHE TECNICHE 16 ...

Page 3: ...d any necessary maintenance of the systems cables and the amplifiers before using them In the event of wear or accidental damage of the components Outline will provi de specific support for their replacement frequently check the conditions and correct operation of the tripods wheelboards and other fixing accessories Since the system is equipped with loudspeakers transducers that produce a static m...

Page 4: ...esistance and control even at high vi bration levels has a number of handles that can also be used to lock the subwoofer with the wheelboard for transport The curved front grille guarantees additional pro tection of the woofer without compromising in any way its acoustic performance and without interefe ring with the ergonomics of the handles Lastly the M20 threaded points allow the use of the sub...

Page 5: ...ery simple as shown here under AC into amplifier Analog signal 3 1 CONNECTORS SPECIFICATIONS The cable used for the audio signal wiring from the source to the subwoofer input panel chapter 4 is a classic audio cable with XLR 3 pole EIA standard connector 1 Ground 2 Positive 3 Negative Alternatively the input panel with Combo connec tor also accepts balanced 6 35 mm jack cables TRS The cable used t...

Page 6: ...ND PICTURES PowerCON True 1 Powercord EU Type A Type B USB cable XLR bal jack 6 35 mm TRS 1 8 m professional power cable for the amplifier Connection cable between the DSP of the kit and the dedicated PC Approved connectors for the SUB118 SP input panel to use with external source signals NAME CODE DESCRIPTION Attention Not included in the package ...

Page 7: ...p of the dedicated potentiometer which can be set from to 6 dB respect to the input signal It is possible to monitor the ratio between the input and output levels with the help of the metering LEDs It is strongly recommended not to reach the clip temp status for long periods of time even though the DSP limiter is set to values for the best protection of the loudspea ker components USB input type B...

Page 8: ...t the same time Before doing this connection you need to download and install the ArmoníaPlus software download at ar monia powersoft it It is also necessary to download and install the dedicated Outline plug in available in Armonía Marketplace For some computers it will be necessary to install the VCP communication plug in www silabs com pro ducts development tools software usb to uart bridge vcp...

Page 9: ...types of filters for input signal equalization indepen dent from the selected preset ideal for circumstances and venues with particularly complex acoustics Overall gain level regulation independent from the level regulation on the amplifier can be useful in case you want to set a digital limit of the final output volume Delay and Polarity up to 340ms delay and polarity change of the whole kit inte...

Page 10: ... the enclosure in standby mode where its power consumption is redu ced to 2 Watts by pushing the Preset button for at least 3 seconds When this mode is on if after 15 minutes there is no input signal 45 dBu the DSP enters the energy saving mode and sends a signal to the power amplifier that deactivates the output stages There is a blue LED on the panel indicating the Sleep Mode is on The module re...

Page 11: ...Cardio configuration designed for application with two or three SUB 118 SP which allows to concentrate the sound emission of the woofer that is quasi omnidirectional by its nature in a narrower field towards the venue not to disturb the stage with unnecessary and exces sive low grequencies see the next chapter 5 PRESETS AND USES The great peculiarity of the SUB 118 SP enclosure is that when you ha...

Page 12: ...at the cardioid configuration and therefore the elimination of the low frequencies on the back has the desi red effect Depending on the number of enclosures here are some possible configurations with the in structions SUB CARDIO with two enclosures put the subs side by side as shown in the picture one of them should be facing the stage 1 and the other one should be facing the venue 2 or stack them...

Page 13: ...he stage and the other two 1 3 facing the venue or stack them as in the drawing on the right with the sub in the middle 2 facing the stage and the other two 1 3 facing the venue Choose the pre set 4 Sub Cardio for the sub in the middle 1 and set its gain potentiometer to 6 dB max while for the other two subs facing the venue 1 3 it is necessary to choose the preset 1 LP 80 Hz CLIP TEMP SIGNAL STAT...

Page 14: ... are not me asurable during everyday use These checks include cables connectors conformity pinouts cuts tears cables safety etc amplifiers and their electrical and thermic safety always verify the amplifier does not overheat during prolonged use frequency response check of the electroacou stic components using a measurement mi crophone and software that can measure the frequency response of the lo...

Page 15: ...e anche per il SUB 118 SP sono disponibili dei componenti di ricambio nell estremo caso di un eventuale guasto Per altri tipi di riparazioni sarà necessario rivolgersi direttamente ad Outline I componenti di ricambio sono i seguenti con i relativi codici SUB 118 SP ricambi woofer 18 quattro piedini modulo di amplificazione con pannello annesso O S18166W4WP M V802 L AME3KV1SP110 ...

Page 16: ...Rated power 2400 W EIAJ at 4 Ω Cooling Cooling Tunnel Variable Speed Fan Special feature selectable input gain and preset Baltic birch plywood Black polyurea coating Epoxy powder coated 570 mm 22 1 2 570 mm 22 1 2 750 mm 29 1 2 47 kg 103 6 lb Nominal Dispersion Power Amplifier Suggested Cross over Maximum SPL Output Component Low Loading Low Amplifier Input Amplifier DC Input Cabinet Material Cabi...

Page 17: ... products without prior notice as a routine result of this phi losophy For this reason any current Outline product may differ in some aspect from its description but will always equal or exceed the original design specifications unless otherwise stated Outline 2020 Operating manual product code Z OMSUB118SP_EN Release 20200228 Printed in Italy ...

Reviews: