FutureNow FNIP-4xSH Installation Manual rev 15.01.2014 

FutureNow FNIP-4xSH-12 and FNIP-4xSH-24 

Installation Manual 

rev 15.01.2014

 

 

TCP/IP and Web Controllable 

Four Channel DIN Rail Window Shading Controller with Local Inputs 

 

 

OVERVIEW 

 

The  FNIP-4xSH  can  be  used  for  controlling  four  motorized  window  coverings,  such  as 
shades,  shutters,  blind,  curtains,  awnings  or  projection  screens  and  any  other  devices 
equipped with four-wire bidirectional AC motors with built-in limit switches either via its local 
inputs, custom TCP protocol or via its built-in web interface. 
 
The  FNIP-4xSH  can  be  controlled  and  monitored  from  standard  network  capable  devices 
such as computers, smartphones, web-tablets, etc. either locally or via the Internet. 

 

Figure 1. The FNIP-4xSH Window Shading Controller 

 
The module can be used independently or as part of a complex control system in residential, 
or commercial installations. 
 

Summary of Contents for FutureNow FNIP-4xSH-12

Page 1: ...torized window coverings such as shades shutters blind curtains awnings or projection screens and any other devices equipped with four wire bidirectional AC motors with built in limit switches either...

Page 2: ...TURES Robust Operation Ideal for motorized window coverings projection screens awnings etc 4 outputs for controlling 4 four wire up down neutral bidirectional AC motors 4x2 up down galvanically isolat...

Page 3: ...trollers from most major vendors Control4 AMX etc Interoperable with any momentary contact switches available on the market INSTALLATION WARNING Since the module is connected to line voltage the insta...

Page 4: ...9 Motor 1 Down Input 4 Motor 2 Up Out 30 Motor 2 Up Input 5 Neutral 31 Inputs common 6 Motor 2 Down Out 32 Motor 2 Down Input 7 Motor 3 Up Out 33 Motor 3 Up Input 8 Neutral 34 Inputs Common 9 Motor 3...

Page 5: ...cross terminals 13 and 14 motors with different power requirements can also be used but all four motor has to be have the same power requirement After making all connections check if the outputs work...

Page 6: ...ts offer not recommended you can use the same power to supply both the main circuitry and the inputs In that case simply connect terminal 39 to terminal 41 and terminal 40 to terminal 42 Ethernet conn...

Page 7: ...input terminals for this purpose See section Power Requirements if you don t want to use two separate power supply units To assure an additional level of safe and reliable operation the inputs are als...

Page 8: ...The red LED indicates the direction of the movement It is off while the motor is moving up and on while the motor is moving down If the motor is not in motion this LED is off Input status LEDs Each ch...

Page 9: ...face Use the FNIP Network Discovery Utility software to find all FutureNow IP devices on your network Connecting to the module s web site After the scan is over you can click on one of the modules fou...

Page 10: ...and functions The default user name is admin The default password is futurenow Once logged in you will automatically be directed to the control page There is a menu on the top of each web page to navi...

Page 11: ...users and setting up user rights Three different users can be defined each with three different user rights admin actor and observer Admins have access to all functionality including control of the o...

Page 12: ...2014 12 Observers are allowed to monitor the status of inputs and outputs but not allowed to control the outputs nor can they change any settings To modify user settings click on User in the top menu...

Page 13: ...___________________________________________ FutureNow FNIP 4xSH Installation Manual rev 15 01 2014 13 Board configuration Clicking on Board in the top menu takes you to the board configuration page wh...

Page 14: ...nput modes and how they work see Operation via local inputs paragraph of this document below Updating the firmware is also possible via this page Logging out You can log out from the module s web page...

Page 15: ...ermediate position Activating the input for the opposite direction while the motor is still moving will cause the motor to change its direction after a short delay You can also move the motor to the d...

Page 16: ...ual rev 15 01 2014 16 Figure 9 Control Page Each input can either be active input terminals shorted or inactive input terminals open A grey icon means that the corresponding input is inactive An activ...

Page 17: ...hieve the easiest integration with most controllers used in home and commercial applications the module can be controlled by raw TCP protocol using simple ASCII based commands The TCP IP communication...

Page 18: ...al purpose controllers there are many applications for embedded industrial PC boards PCs and smartphones running Linux Windows Mac OS Firmware upgrade Upgrading the firmware of the module is possible...

Page 19: ...Terminals Type Screw terminals for max 2 5 mm2 wires Communication 10Mb s Ethernet via RJ45 Ethernet connector Simple ASCII based TCP commands via port 7078 by default Number of socket connections tha...

Page 20: ..._____________________________________________________________________________ FutureNow FNIP 4xSH Installation Manual rev 15 01 2014 20 REFERENCES FNIP Search Utility FNIP 4xSH TCP Communication Proto...