background image

SX-70 Sodr-X-Tractor Handpiece

Operation & Maintenance Instructions

SX-70

Summary of Contents for SX-70 SODR-X-TRACTOR

Page 1: ...SX 70Sodr X TractorHandpiece Operation MaintenanceInstructions SX 70...

Page 2: ...hermoJet ThermoPart ThermoPik ThermoTweez The following are trademarks and or servicemarks of PACE Incorporated Laurel Maryland U S A and may only be used to identify genuine PACE products or services...

Page 3: ...SX 70 3 SX 70 Sodr X TractorHandpiece PartNumber6010 0100 ManualNumber5050 0334 Rev E...

Page 4: ...hen not in use Failure to do so may cause burns to the operator equipment or work surfaces and may be a potential ignition source if combustible materials are nearby Always use this handpiece in a wel...

Page 5: ...ed to some PACE power sources Refer to the power source Operation Maintenance manual for the applicable instructions 3 Place the sponge in the Tip Tool Stand using the following procedure a Remove the...

Page 6: ...to either the Vacuum Port or Controllable PRESSURE Port at one time Attachment to both ports simultaneously will cause a deterioration of performance To set up your SX 70 air hose connection perform t...

Page 7: ...ir fittings are supplied with each additional air handpiece a Disconnect the 137cm 54 inch length of air hose from the FLOW IN side of the VisiFilter assembly Insert the ribbed end of a male quick con...

Page 8: ...D should not exceed the diameter of the land to minimize risk of damage to the board substrate When removing TQFPs or TSOPs the Pik Tip should be sized so that the tip blades make proper contact with...

Page 9: ...oard 3 All 3 16 shank tips are tinnable Using a large gauge flux cored wire solder tin the end of these tips Proper tinning enhances heat transfer to lands and extends tip life 4 During Flo desolderin...

Page 10: ...th motion for flat leads until the lead moves freely Free lead movement indicates that complete solder melt has been obtained 5 While continuing to move lead actuate vacuum with the finger switch and...

Page 11: ...e clogged with such material If this should occur clean the tip with the Tip Cleaning Kit PACE part number 6993 0200 by inserting the wire tool into the tip end SpecialApplications If you require assi...

Page 12: ...nt of the handpiece and turning counterclockwise to disengage The glass chamber can be easily removed if it remains in the handpiece when the end cap assembly is removed Insert a small flat blade scre...

Page 13: ...eplace if any damage is evident 5 Assemble the solder collection chamber by installing the S Baffle item and a new Filter item into the chamber The S Baffle should have enough tension to maintain a co...

Page 14: ...to Pin 5 Resistance should be 8 2 to 9 5 ohms If not Shorted Heater Replace Heater Assembly N Ch k i t Pi 4 t O id ti Cl H t Handpiece Connector Plug Corrective Maintenance Your SX 70 requires no spe...

Page 15: ...1 Glass Chamber 1265 0009 P1 Tubing Silicone Translucent 54 Inches Long 1342 0001 13 Holder Tube To Wire pkg of 6 1321 0085 01 S Baffle 4010 0033 Filter glass chamber 1309 0018 P50 VisiFilter 1309 002...

Reviews: