24 Months warranty for complete system
•
6 Months warranty for Printed Circuit Board
Exit program, cancel call
23
Lock-out Count
Save program
24
Alarm
0= disable
1= local beep for 60
seconds
2= disable system for 60
seconds with no beep
3= call directory (0-9)
00
Change master code (0000
is default)
25
Keypad beep
0= disable (default)
1=enable
01
Add new forwarding tenant’s
directory
26
Door beep
0= disable
1= enable (default)
02
Edit existing tenant’s
directory
27
Talk time (060-240
second). Default=60
second
03
Delete existing tenant’s
directory
28
Unlock relay1 time
(12-99 second).
Default= 12 second
04
Clear all forwarding tenant’s
directory
29
Unlock relay2 time
(12-99 second).
Default= 12 second
05
Enable/Disable Call
33
Temporary code
06
New access code
34
Special code
07
Delete access code
35
Temporary card
08
Clear all access code
36
Special card
09
Access code digit (4-8 digit).
Default is 4-digit
38
System acknowledge
(0-9). Default= 3
10
Add new card
39
Remote access
0= disable
1=enable (default)
11
Delete card
40
DTMF relay 1 (0-9).
Default=9
12
Clear all card
41
DTMF relay 2 (0-9).
Default=8
13
Set time
42
Relay 2 Mode
1= door control (default)
2= relay 2 trigger
simultaneously as relay
1
3= enable if function
code 24 is enabled
4= turn relay 2 on and
off
On=7, Off=6
14
Set date
43
DND: do not disturb time
zone (0-9)
15
Initializing event recording
44
Disable Time zone relay
1, 2 or both
16
AUS= auto unlock schedule
(0-9 schedule)
45
Relay 1 and 2 unlock
timer
17
TMZ= time zone. 20 TMZ,
00-20.
46
Firmware version
18
HLD= holiday zone. 20 HLD,
1-20
48
PBX enable. Default=
disable
19
Directory digit (2-4 digit).
Default is 2-digit
49
Edit Access code
20
AUXIN1
0= disable (default)
1= enable control by relay 1
open interval
2= relay 1 control by AuxIn2
50
Erase the memory to
factory default
21
AUXIN2
0= disable (default)
1= enable control by relay 2
open interval
2= relay 2 control by AuxIn2
51
Welcome screen
22
Do not disturb
0= disable (default),
1= enable
Log on to programming:
Press
simultaneously then
release, the welcome message will
stop scrolling (repeat if screen still
scrolling) enter 4-
digit “
MASTER
CODE
” (0000 is default), the screen
will show as below:
Select the “
Function Code
” from
the table
OPERATION
Two ways to call tenant
1. Press
to scroll name from A-Z or
to scroll name
from Z-A then press
to call name selected.
2. Press
wait for dial tone then press the directory
number
Opening the door remotely
press
(relay 1) or
(relay 2)
Open the door with the access code
press
(display
screen will stop scrolling) then press a valid 4-digit access
code.
Extend talk time
tenant must press
from the phone
after the time out warning beep.
Call into the system
:
1. Enable function code 39 and function code 38 must be
set 1-9
2. Call the system phone number, hear one beep if the
system
answering the call.
3. Press
then 4-digit master code, hear one short
beep
4. Press
to establish two ways communication
5. Press
or
to release the door.
.
QWCM BROWSER DEFAULT IP
IP: 192.168.1.230
SUBNET: 255.255.255.0
GATEWAY: 192.168.1.1
DNS: 192.168.1.1
USERNAME: Administrator
PASSWORD: pach or 8888
QUANTUM QVOIP SERIES
PACH AND COMPANY INC.
QUICK GUIDE