background image

111206-16 VISTA 

and 

CLASSIC-C 

5055.3

TESTED and LISTED

to CAN/ULC S627-M93 AND UL 1482-98

Meets the U.S. Environmental Protection 
Agency's July 1990 Particulate Emission 

Standards

SERIES - C

SAFETY NOTICE

If this stove is not properly 
installed, a house fire may 
result. For your safety, follow 
t h e   i n s t a l l a t i o n   d i r e c t i o n s . 

 

C o n t a c t   l o c a l   b u i l d i n g   o r 
fire officials about restrictions 
and installation inspection 
requirements in your area.

INSTALLATION 

AND OPERATING 

INSTRUCTIONS

PLEASE SAVE THESE INSTRUCTIONS

Models

Pacifi c VISTA

VISTA CLASSIC

STUDY CAREFULLY BEFORE 

PROCEEDING

Summary of Contents for Paci?c VISTA

Page 1: ...C SAFETY NOTICE If this stove is not properly installed a house fire may result For your safety follow the installation directions Contact local building or fire officials about restrictions and inst...

Page 2: ...Y AND MAINTENANCE 3 ASSEMBLY 4 MOBILE HOME INSTALLATION 6 RESIDENTIAL INSTALLATION 7 FLOOR PROTECTOR 7 COMBUSTION AIR 8 WOOD SELECTION 8 OPERATING 8 PROPER DRAFT 9 ASH REMOVAL 9 BAFFLE REMOVAL 9 OPTIO...

Page 3: ...onnect the detectors If necessary relocate them to reduce their sensitivity SAFETY NOTICE IF THIS STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RE SULT FOR YOUR SAFETY FOLLOW THE INSTALLATION DIREC...

Page 4: ...stal mounting holes with the studs on stove bottom 2 Secure in place with 1 2 nuts previously removed 3 Carefully place the unit in an upright position LEG KIT 1 With the unit on its back and removabl...

Page 5: ...Chimney Roof ashing Storm collar Hooded vent Attachment to oor for mobile homes Spark arrestor rain cap FIG 2 7 2 1 m Minimum Ceiling Height 58 1473 mm Minimum 48 1219 mm Minimum The chimney may incor...

Page 6: ...upplier for installation advice PROCEDURE Note See Combustion Air section on page 9 1 Position stove and oor protection with the clearances as stated on the label or as in Figure 1a and 1b page 4 5 2...

Page 7: ...ntingdown This will carry any liquid creosote or condensation back into the stove Thechimneyconnectorshouldnotpassthroughatticorroof space closet or similar concealed space or oor ceiling wall or part...

Page 8: ...nder no circumstances should you attempt to barbecue in this heater HOW TO TEST YOUR WOOD Add a large piece of wood to the stove when it has a good large bed of coals It is dry if it is burning on mor...

Page 9: ...e room through appliance and chimney connector joints indicates inadequate draft ASH REMOVAL When ever ashes get 3 to 4 inches deep in your rebox and when rehasburneddownandcooled removeexcessashes Le...

Page 10: ...t leakage Replace gasket Check latch EXCESSIVE CREOSOTE BUILDUP See 1 2 3 above LOW HEAT OUTPUT 1 Wood is wet Use dry wood 2 Fire too small Build a larger re 3 Draft too low Chimney plugged or restric...

Page 11: ...open When wood is burned slowly it produces tar and other or ganic vapours which combine with expelled moisture to form creosote The creosote vapours condense in the relatively cool chimney ue of a s...

Page 12: ...ST VSNI 9 DOOR HANDLE ASSEMBLY WODC 4147 10 BOOST MANIFOLD 2105 11a FIREBRICK 1 1 2 x 4 1 2 x 1 1 4 248 11b FIREBRICK 3 x 4 1 2 x 1 1 4 247 11c FIREBRICK 4 x 4 1 2 x 1 1 4 246 11d FIREBRICK 9 x 4 1 2...

Page 13: ...x 4 1 2 x 1 1 4 248 11b FIREBRICK 3 x 4 1 2 x 1 1 4 247 11c FIREBRICK 4 x 4 1 2 x 1 1 4 246 11d FIREBRICK 9 x 4 1 2 x 1 1 4 5096 99 FIREBRICK SET BRIC VISTA 12a BRICK RAIL LEFT 2122 12b BRICK RAIL RI...

Page 14: ...the heater in the upright position install rebricks as follows First install 4 full size rebricks against the rear wall Next install the side rebricks 2 full size each side Lastly place 4 full size on...

Page 15: ...MODEL HT 3000 SELKIRK SENTINEL MODEL CF INDUSTRIAL CHIMNEY MODEL EXCEL 2100 ENERGY VENT COMMANDER 5000 IN USA SECURITY MODEL ASHT OR S2100 OLIVER MACLEOD MODEL 3103 OR HT 3000 SELKIRK METALBESTOS MODE...

Page 16: ...16 VISTA and CLASSIC C 111206 16 Printed in Canada PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan BC V9L 6V8 Phone 888 715 2398 Web site www paci cenergy net...