background image

050515-24 SPNE 

5055.101.B

MODEL:
SUPER  INSERT
DESIGN-E
SPNE

SAFETY NOTICE

If this stove is not properly installed, a house 

fi re may result. For your safety, follow the 

installation directions. Consult local building 

inspector or officials about restrictions and 

installation inspection requirements in your 

area.

Super Insert

IMPORTANT:

THESE INSTRUCTIONS ARE TO 
REMAIN WITH THE HOMEOWNER
SAVE THESE INSTRUCTIONS

INSTALLATION 

AND OPERATING 

INSTRUCTIONS

TESTED and LISTED 
to ULC S628 / UL 1482

Meets the U.S. Environmental Protection 
Agency's May 2015 Particulate Emission
Standards 

SERIAL #

©PACIFIC ENERGY FIREPLACE 
PRODUCTS LTD. - 2014

Summary of Contents for SUPER INSERT DESIGN-E SPNE

Page 1: ...inspector or officials about restrictions and installation inspection requirements in your area Super Insert IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS INSTA...

Page 2: ...ation 20 Warranty Information 21 Label 23 PLEASE SAVE THESE INSTRUCTIONS This manual describes the installation and operation of the Pacific Energy SUPER INSERT wood heater This heater meets the 2015...

Page 3: ...ing or fire officials about restric tions and installation inspection requirements in your area Clearances Masonry or Factory Built Fireplace Theminimumrequiredclearancestosurroundingcombustible mater...

Page 4: ...p baffle board blanket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Some warping of the baffle is normal up to 1 4 or 65cm Replace if the baffle has permanent warping gr...

Page 5: ...protected from hot embers by non combustible material extending 16 USA and 18 CANADA to the firing side and 8 to other sides of the unit Consult CAN CSA B365 Installation Code for Solid Fuel Burning...

Page 6: ...6 SPNE 050515 24 PACIFIC ENERGY FIREPLACE PRODUCTS LTD 43 3 8 6 1 2 29 3 16 23 3 4 21 1 2 21 1 8 36 8 3 4 20 3 4 18 28 1 8 9 1 2 10 21 Dimensions...

Page 7: ...ly if it has not been in use for some time The existing fireplace damper is to be locked open or removed completely WARNING Do not remove bricks or mortar from your existing fireplace Exception Masonr...

Page 8: ...tile Seal around pipe Note A clean out door may be required under local codes when a direct flue connection is used Consult local codes 3 Push the Insert into position inside the fireplace and at tach...

Page 9: ...m the fans LHS RHS and thermal snap switch Take note of where the wires are routed and secured They must be positioned correctly to avoid damage 3 Loosen the two bolts that secure the ash lip to the f...

Page 10: ...d thermal snap switch Fig 16 refit ash lip sides and top Ensure that the power cable is correctly routed through the surround and it is not touching the firebox side Wire placement is important to pre...

Page 11: ...anels as described on page 9 and then remove the decorative top by loosening the two wing bolts underneath and sliding it out of the brackets Fig 18 4 Slide the assembled surround from the top down an...

Page 12: ...Insert as described in the installation section When the installation is complete do not seal surround to fireplace This will allow enough combustion air to enter the fireplace cavity and the Insert...

Page 13: ...l operation after a good coal base exists and wood has charred Curing of the Paint Finish When burning your stove for the first 2 3 times it is very im portant that the room be well ventilated Open al...

Page 14: ...or open damage to door gaskets allowing excess air to enter the firebox the use of kiln dried lumber mill ends or paper waste and prolonged or continual use on a high burn setting Heat Output Calculat...

Page 15: ...urn Smoke free clean burning requires small fuel loads two or three logs at a time or 1 4 to 1 2 of fuel load and leaving the air inlet relatively wide open especially during the first 10 to 30 minute...

Page 16: ...s cracked or broken it must be replaced before using the stove Re placement glass can be obtained from your Dealer The size required is 8 13 16 x 15 1 4 x 5 mm Ceramic glass must be used Do not substi...

Page 17: ...CAST 31RSNI 12 Door Handle Assembly WODC 4147C 13 Flame Shield WINS 4513 14 Replacement Baffle Kit SSER DBAKIT 15 Brick Rail Set SSER RAILSET 16 Firebrick Set BRIC SSERA 17 Boost Manifold 4105 18 O A...

Page 18: ...high mass weight acts as a heat storage andthethermalinsulation keeps the combustion zone hot Active flaming takesplaceduringthefirst part of the burn During this stage heat is stored in the mass of t...

Page 19: ...1 2 and 3 above 2 Door Gasket leakage Replace gasket Check latch Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Area too large 4 Poor insulation or open concrete Won...

Page 20: ...rt Firebrick Installation This package contains 18 full size firebricks as well as 1 cut size brick With the heater in the upright position install firebricks as follows Place firebricks on the bottom...

Page 21: ...is operating correctly at installation Any part that shows in our judgment evidence of defect shall be repaired replaced or refunded at Pacific Energy s option The defective part may be required to be...

Page 22: ...22 SPNE 050515 24 PACIFIC ENERGY FIREPLACE PRODUCTS LTD NOTES...

Page 23: ...LENBY RD DUNCAN BC V9L 6V8 INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY S INSTALLATION AND OPERATING INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES RESTRICTIONS AND INSTAL...

Page 24: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD PACIFIC ENERGY FIREPLACE PRODUCTS LTD www pacificenergy net Phone 1 250 748 1184 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...